Cited by 58Hormonal and reproductive studiesClinical Laboratory Practices and Quality ControlAdrenal Hormones and Disorders

Analog-Based Free Testosterone Test Results Linked to Total Testosterone Concentrations, Not Free Testosterone Concentrations

Fritz, Kristofer S, McKean, Alastair J S, Nelson, Jerald C, Wilcox, R Bruce·2008·Clinical Chemistry

Abstract

Background: Analog-based free testosterone test results, sex hormone binding globulin (SHBG) concentrations, and total testosterone concentrations are somehow related. This study used new experiments to clarify these relationships. Methods: An analog-based free testosterone immunoassay and a total testosterone immunoassay were applied to well-defined fractions of serum testosterone. First, they were applied to the 2 fractions (retentate and dialysate) of normal male serum obtained by equilibrium dialysis. Second, they were applied to covaried concentrations of SHBG and total testosterone. Third, they were applied to decreasing concentrations of SHBG and protein-bound testosterone, offset by increasing concentrations of protein-free testosterone, while total testosterone was held constant. Results: The analog-based free testosterone assay and the total testosterone assay detected and reported serum testosterone test results from serum retentate, whereas neither assay detected the free testosterone in serum dialysate. Test results reported by the analog-based free testosterone assay followed varied concentrations of SHBG and total testosterone. When total testosterone was held constant, however, analog-based free testosterone test results did not follow varied concentrations of serum proteins or of free testosterone. Conclusion: An analog-based free testosterone immunoassay reported free testosterone test results that were related to total testosterone concentrations under varied experimental conditions. This alleged free testosterone assay did not detect serum free testosterone (the test results it reported were nonspecific) and should not be used for this purpose.

Integrity signals

Registry

Crossref · 10.1373/clinchem.2007.094870

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fritz, K. S., McKean, A. J. S., Nelson, J. C., & Wilcox, R. B.
Affiliations
  • Loma Linda University (US)
  • Loma Linda University Medical Center (US)
Corresponding author
Wilcox, R Bruce
Venue
Clinical Chemistry
Published
2008-03-01
Volume
54
Issue
3
Pages
512-516
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2116313303
Cited by
58
References
5
Citations by year
2026: 2 · 2025: 2 · 2022: 2 · 2021: 7 · 2020: 2 · 2019: 2 · 2017: 1 · 2016: 5 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 3
FWCI
4.82
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
Keywords
free testosterone, total testosterone, sex hormone-binding globulin, equilibrium dialysis, immunoassay validation
MeSH terms
Adult, Dialysis, Humans, Immunoassay, Male, Middle Aged, Protein Binding, Sex Hormone-Binding Globulin, Testosterone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review