The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reference Intervals for Serum Creatinine Concentrations: Assessment of Available Data for Global Application
Open accessAbstract
Background: Reference intervals for serum creatinine remain relevant despite the current emphasis on the use of the estimated glomerular filtration rate for assessing renal function. Many studies on creatinine reference values have been published in the last 20 years. Using criteria derived from published IFCC documents, we sought to identify universally applicable reference intervals for creatinine via a systematic review of the literature. Methods: Studies were selected for inclusion in the systematic review only if the following criteria were met: (a) reference individuals were selected using an “a priori” selection scheme, (b) preanalytical conditions were adequately described; (c) traceability of the produced results to the isotope dilution–mass spectrometry (IDMS) reference method was demonstrated experimentally, and (d) the collected data received adequate statistical treatment. Results: Of 37 reports dealing specifically with serum creatinine reference values, only 1 report with pediatric data and 5 reports with adult data met these criteria. The primary reason for exclusion of most papers was an inadequate demonstration of measurement traceability. Based on the data of the selected studies, we have collated recommended reference intervals for white adults and children. Conclusion: Laboratories using methods producing traceable results to IDMS can apply the selected reference intervals for serum creatinine in evaluating white individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Cited by
The definition of acute kidney injury and its use in practice
Thomas, M. E., Blaine, C., Dawnay, A., Devonald, M. A. J., Ftouh, S., Laing, C., Latchem, S., Lewington, A., Milford, D. V., & Ostermann, M. (2015) · Kidney International · doi:10.1038/ki.2014.328 · Cited by 722
Colantonio, D. A., Kyriakopoulou, L., Chan, M. K., Daly, C. H., Brinc, D., Venner, A. A., Pasic, M. D., Armbruster, D., & Adeli, K. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.177741 · Cited by 479
Establishing Reference Intervals for Clinical Laboratory Test Results: Is There a Better Way?
Katayev, A., Balciza, C., & Seccombe, D. W. (2010) · American Journal of Clinical Pathology · doi:10.1309/ajcpn5bmtsf1cdyp · Cited by 280
Reference intervals: current status, recent developments and future considerations
Ozarda, Y. (2016) · Biochemia Medica · doi:10.11613/bm.2016.001 · Cited by 264
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Self-citation
Metadata
- Authors
- Ceriotti, F., Boyd, J. C., Klein, G., Henny, J., Queraltó, J., Kairisto, V., Panteghini, M., & the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL)
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-03-01
- Volume
- 54
- Issue
- 3
- Pages
- 559-566
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2164879200
- Cited by
- 252
- References
- 1
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference Intervals for Serum Creatinine Concentrations: Assessment of Available Data for Global Application. https://app.cochat.ai/papers/10.1373/clinchem.2007.099648
- The paper
- Ceriotti, F., Boyd, J. C., Klein, G., Henny, J., Queraltó, J., Kairisto, V., Panteghini, M., & the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL). (2008). Reference Intervals for Serum Creatinine Concentrations: Assessment of Available Data for Global Application. Clinical Chemistry. https://doi.org/10.1373/clinchem.2007.099648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.