The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High-Abundance Polypeptides of the Human Plasma Proteome Comprising the Top 4 Logs of Polypeptide Abundance
Abstract
Background: Plasma contains thousands of proteins, but a small number of these proteins comprise the majority of protein molecules and mass. Content: We surveyed proteomic studies to identify candidates for high-abundance polypeptide chains. We searched the literature for information on the plasma concentrations of the most abundant components in healthy adults and for the molecular mass of the mature polypeptide chains in plasma. Because proteomic studies usually dissociate proteins into polypeptide chains or detect short peptide segments of proteins, we summarized data on individual peptide chains for proteins containing multiple subunits or polypeptides. We collected data on about 150 of the most abundant polypeptides in plasma. The abundant polypeptides span approximately the top 4 logs of concentration in plasma, from 650 to 0.06 μmol/L on a molar basis or from about 50 000 to 1 mg/L mass abundance. Conclusions: Data on the concentrations of the high-abundance peptide chains in plasma assist in understanding the composition of plasma and potential approaches for clinical laboratory or proteomic analysis of plasma proteins. Development of more extensive databases regarding the plasma concentrations of proteins in health and diseases would promote diagnostic and proteomic advances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute-Phase Proteins and Other Systemic Responses to Inflammation
Gabay, C., & Kushner, I. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400607 · Cited by 6,734
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Self-citationPieper, R., Su, Q., Gatlin, C. L., Huang, S., Anderson, N. L., & Steiner, S. (2003) · PROTEOMICS · doi:10.1002/pmic.200390057 · Cited by 356
Self-citation
Cited by
Monopoli, M. P., Walczyk, D., Campbell, A., Elia, G., Lynch, I., Baldelli Bombelli, F., & Dawson, K. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja107583h · Cited by 1,835
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Kuzyk, M. A., Smith, D., Yang, J., Cross, T. J., Jackson, A. M., Hardie, D. B., Anderson, N. L., & Borchers, C. H. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800540-mcp200 · Cited by 515
Self-citationA High-Confidence Human Plasma Proteome Reference Set with Estimated Concentrations in PeptideAtlas
Farrah, T., Deutsch, E. W., Omenn, G. S., Campbell, D. S., Sun, Z., Bletz, J. A., Mallick, P., Katz, J. E., Malmström, J., Ossola, R., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.006353 · Cited by 451
Interferences from blood collection tube components on clinical chemistry assays
Bowen, R. A. R., & Remaley, A. T. (2014) · Biochemia Medica · doi:10.11613/bm.2014.006 · Cited by 316
Metadata
- Authors
- Hortin, G. L., Sviridov, D., & Anderson, N. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-10-01
- Volume
- 54
- Issue
- 10
- Pages
- 1608-1616
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2142970078
- Cited by
- 269
- References
- 3
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Abundance Polypeptides of the Human Plasma Proteome Comprising the Top 4 Logs of Polypeptide Abundance. https://app.cochat.ai/papers/10.1373/clinchem.2008.108175
- The paper
- Hortin, G. L., Sviridov, D., & Anderson, N. L. (2008). High-Abundance Polypeptides of the Human Plasma Proteome Comprising the Top 4 Logs of Polypeptide Abundance. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.108175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.