Multiple reaction monitoring-based, multiplexed, absolute quantitation of 45 proteins in human plasma
Open accessAbstract
Mass spectrometry-based multiple reaction monitoring (MRM) quantitation of proteins can dramatically impact the discovery and quantitation of biomarkers via rapid, targeted, multiplexed protein expression profiling of clinical samples. A mixture of 45 peptide standards, easily adaptable to common plasma proteomics work flows, was created to permit absolute quantitation of 45 endogenous proteins in human plasma trypsin digests. All experiments were performed on simple tryptic digests of human EDTA-plasma without prior affinity depletion or enrichment. Stable isotope-labeled standard peptides were added immediately following tryptic digestion because addition of stable isotope-labeled standard peptides prior to trypsin digestion was found to generate elevated and unpredictable results. Proteotypic tryptic peptides containing isotopically coded amino acids ([(13)C(6)]Arg or [(13)C(6)]Lys) were synthesized for all 45 proteins. Peptide purity was assessed by capillary zone electrophoresis, and the peptide quantity was determined by amino acid analysis. For maximum sensitivity and specificity, instrumental parameters were empirically determined to generate the most abundant precursor ions and y ion fragments. Concentrations of individual peptide standards in the mixture were optimized to approximate endogenous concentrations of analytes and to ensure the maximum linear dynamic range of the MRM assays. Excellent linear responses (r > 0.99) were obtained for 43 of the 45 proteins with attomole level limits of quantitation (<20% coefficient of variation) for 27 of the 45 proteins. Analytical precision for 44 of the 45 assays varied by <10%. LC-MRM/MS analyses performed on 3 different days on different batches of plasma trypsin digests resulted in coefficients of variation of <20% for 42 of the 45 assays. Concentrations for 39 of the 45 proteins are within a factor of 2 of reported literature values. This mixture of internal standards has many uses and can be applied to the characterization of trypsin digestion kinetics and plasma protein expression profiling because 31 of the 45 proteins are putative biomarkers of cardiovascular disease.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Various LC-MS/MS assays for multiplexed quantification of apolipoproteins or phenotyping of apoE have been reported.
“Various LC-MS/MS assays for multiplexed quantification of apolipoproteins (14-23) or phenotyping of apoE (24-27) have been reported.”
From Automated multiplex LC-MS/MS assay for quantifying serum apolipoproteins A-I, B, C-I, C-II, C-III, and E with qualitative apolipoprotein E phenotyping (2016) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Anderson, N. L., Anderson, N. G., Haines, L. R., Hardie, D. B., Olafson, R. W., and Pearson, T. W. (2004) Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA). J. Proteome Res. 3, 235-244
Cited by
Sorted by citations
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491 · see citing works
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302 · see citing works
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288 · see citing works
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037 · see citing works
Self-citationCarr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561 · see citing works
Self-citationTargeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510 · see citing works
Abbatiello, S. E., Schilling, B., Mani, D. R., Zimmerman, L. J., Hall, S. C., MacLean, B., Albertolle, M., Allen, S., Burgess, M., Cusack, M. P., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.047050 · Cited by 215 · see citing works
Self-citationLiu, Y., Hüttenhain, R., Surinova, S., Gillet, L. C., Mouritsen, J., Brunner, R., Navarro, P., & Aebersold, R. (2013) · PROTEOMICS · doi:10.1002/pmic.201200417 · Cited by 204 · see citing works
Applications of targeted proteomics in systems biology and translational medicine
Ebhardt, H. A., Root, A., Sander, C., & Aebersold, R. (2015) · PROTEOMICS · doi:10.1002/pmic.201500004 · Cited by 184 · see citing works
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109 · see citing works
van den Broek, I., Romijn, F. P. H. T. M., Nouta, J., van der Laarse, A., Drijfhout, J. W., Smit, N. P. M., van der Burgt, Y. E. M., & Cobbaert, C. M. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.246702 · Cited by 105 · see citing works
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80 · see citing works
Eshghi, A., Pistawka, A. J., Liu, J., Chen, M., Sinclair, N. J. T., Hardie, D. B., Elliott, M., Chen, L., Newman, R., Mohammed, Y., et al. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001820 · Cited by 51 · see citing works
Self-citationLassman, M. E., McLaughlin, T. M., Somers, E. P., Stefanni, A. C., Chen, Z., Murphy, B. A., Bierilo, K. K., Flattery, A. M., Wong, K. K., Castro‐Perez, J. M., et al. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5296 · Cited by 51 · see citing works
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2012) · Analytical Chemistry · doi:10.1021/ac302616m · Cited by 38 · see citing works
Novel effects of hormonal contraceptive use on the plasma proteome
Josse, A. R., Garcia-Bailo, B., Fischer, K., & El-Sohemy, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045162 · Cited by 35 · see citing works
“Novel technologies in the field of proteomics allow for the measurement of multiple high-abundance plasma proteins involved in several disease processes simultaneously [18,19].”
BackgroundMethodHan, S.-H., Kim, J. S., Lee, Y., Choi, H., Kim, J.-W., Na, D. L., Yang, E. G., Yu, M.-H., Hwang, D., Lee, C., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.028639 · Cited by 29 · see citing works
Froehlich, B. C., Popp, R., Sobsey, C. A., Ibrahim, S., LeBlanc, A. M., Mohammed, Y., Aguilar‐Mahecha, A., Poetz, O., Chen, M. X., Spatz, A., et al. (2020) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.202000034 · Cited by 9 · see citing works
Self-citation
- Authors
- Kuzyk, M. A., Smith, D., Yang, J., Cross, T. J., Jackson, A. M., Hardie, D. B., Anderson, N. L., & Borchers, C. H.
- Affiliations
- University of Victoria (CA)
- Corresponding author
- Borchers, Christoph H.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2009-08
- Volume
- 8
- Issue
- 8
- Pages
- 1860-1877
- ISSN
- 1535-9476 (ISSN-L)
- PMC
- PMC2722777
- OpenAlex
- W1974500649
- Cited by
- 515
- References
- 1
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 7 · 2023: 13 · 2022: 10 · 2021: 11 · 2020: 21 · 2019: 19 · 2018: 20 · 2017: 30 · 2016: 23 · 2015: 46 · 2014: 51 · 2013: 62 · 2012: 85
- FWCI
- 25.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Molecular & Cellular Proteomics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Genome Canada
- Genome British Columbia
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- multiple reaction monitoring, human plasma, stable isotope-labeled peptides, trypsin digestion, cardiovascular biomarkers, biomarker discovery
- MeSH terms
- Blood Proteins, Chromatography, High Pressure Liquid, Humans, Male, Reference Standards, Mass Spectrometry, Trypsin, Reproducibility of Results, Electrophoresis, Capillary, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review