Cited by 515Advanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

Multiple reaction monitoring-based, multiplexed, absolute quantitation of 45 proteins in human plasma

Open access
Kuzyk, Michael A., Smith, Derek, Yang, Juncong, Cross, Tyra J., Jackson, Angela M., Hardie, Darryl B., Anderson, N. Leigh, Borchers, Christoph H.·2009·Molecular & Cellular Proteomics

Abstract

Mass spectrometry-based multiple reaction monitoring (MRM) quantitation of proteins can dramatically impact the discovery and quantitation of biomarkers via rapid, targeted, multiplexed protein expression profiling of clinical samples. A mixture of 45 peptide standards, easily adaptable to common plasma proteomics work flows, was created to permit absolute quantitation of 45 endogenous proteins in human plasma trypsin digests. All experiments were performed on simple tryptic digests of human EDTA-plasma without prior affinity depletion or enrichment. Stable isotope-labeled standard peptides were added immediately following tryptic digestion because addition of stable isotope-labeled standard peptides prior to trypsin digestion was found to generate elevated and unpredictable results. Proteotypic tryptic peptides containing isotopically coded amino acids ([(13)C(6)]Arg or [(13)C(6)]Lys) were synthesized for all 45 proteins. Peptide purity was assessed by capillary zone electrophoresis, and the peptide quantity was determined by amino acid analysis. For maximum sensitivity and specificity, instrumental parameters were empirically determined to generate the most abundant precursor ions and y ion fragments. Concentrations of individual peptide standards in the mixture were optimized to approximate endogenous concentrations of analytes and to ensure the maximum linear dynamic range of the MRM assays. Excellent linear responses (r > 0.99) were obtained for 43 of the 45 proteins with attomole level limits of quantitation (<20% coefficient of variation) for 27 of the 45 proteins. Analytical precision for 44 of the 45 assays varied by <10%. LC-MRM/MS analyses performed on 3 different days on different batches of plasma trypsin digests resulted in coefficients of variation of <20% for 42 of the 45 assays. Concentrations for 39 of the 45 proteins are within a factor of 2 of reported literature values. This mixture of internal standards has many uses and can be applied to the characterization of trypsin digestion kinetics and plasma protein expression profiling because 31 of the 45 proteins are putative biomarkers of cardiovascular disease.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.m800540-mcp200

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Anderson, N. L., Anderson, N. G., Haines, L. R., Hardie, D. B., Olafson, R. W., and Pearson, T. W. (2004) Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA). J. Proteome Res. 3, 235-244

Cited by

Sorted by citations

Authors
Kuzyk, M. A., Smith, D., Yang, J., Cross, T. J., Jackson, A. M., Hardie, D. B., Anderson, N. L., & Borchers, C. H.
Affiliations
University of Victoria (CA)
Corresponding author
Borchers, Christoph H.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2009-08
Volume
8
Issue
8
Pages
1860-1877
ISSN
1535-9476 (ISSN-L)
OpenAlex
W1974500649
Cited by
515
References
1
Citations by year
2026: 8 · 2025: 7 · 2024: 7 · 2023: 13 · 2022: 10 · 2021: 11 · 2020: 21 · 2019: 19 · 2018: 20 · 2017: 30 · 2016: 23 · 2015: 46 · 2014: 51 · 2013: 62 · 2012: 85
FWCI
25.20
Type
journal article
Language
en
Open access
Locations
  • Molecular & Cellular Proteomics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Genome Canada
  • Genome British Columbia
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
multiple reaction monitoring, human plasma, stable isotope-labeled peptides, trypsin digestion, cardiovascular biomarkers, biomarker discovery
MeSH terms
Blood Proteins, Chromatography, High Pressure Liquid, Humans, Male, Reference Standards, Mass Spectrometry, Trypsin, Reproducibility of Results, Electrophoresis, Capillary, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review