Use of Saliva-Based Nano-Biochip Tests for Acute Myocardial Infarction at the Point of Care: A Feasibility Study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Background: For adults with chest pain, the electrocardiogram (ECG) and measures of serum biomarkers are used to screen and diagnose myocardial necrosis. These measurements require time that can delay therapy and affect prognosis. Our objective was to investigate the feasibility and utility of saliva as an alternative diagnostic fluid for identifying biomarkers of acute myocardial infarction (AMI). Methods: We used Luminex and lab-on-a-chip methods to assay 21 proteins in serum and unstimulated whole saliva procured from 41 AMI patients within 48 h of chest pain onset and from 43 apparently healthy controls. Data were analyzed by use of logistic regression and area under curve (AUC) for ROC analysis to evaluate the diagnostic utility of each biomarker, or combinations of biomarkers, in screening for AMI. Results: Both established and novel cardiac biomarkers demonstrated significant differences in concentrations between patients with AMI and controls without AMI. The saliva-based biomarker panel of C-reactive protein, myoglobin, and myeloperoxidase exhibited significant diagnostic capability (AUC = 0.85, P < 0.0001) and in conjunction with ECG yielded strong screening capacity for AMI (AUC = 0.96) comparable to that of the panel (brain natriuretic peptide, troponin-I, creatine kinase-MB, myoglobin; AUC = 0.98) and far exceeded the screening capacity of ECG alone (AUC approximately 0.6). En route to translating these findings to clinical practice, we adapted these unstimulated whole saliva tests to a novel lab-on-a-chip platform for proof-of-principle screens for AMI. Conclusions: Complementary to ECG, saliva-based tests within lab-on-a-chip systems may provide a convenient and rapid screening method for cardiac events in prehospital stages for AMI patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Task Force Members, Thygesen, K., Alpert, J. S., White, H. D., Biomarker Group, Jaffe, A. S., Apple, F. S., Galvani, M., Katus, H. A., Newby, L. K., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm355 · Cited by 2,541
Self-citationMyeloperoxidase Serum Levels Predict Risk in Patients With Acute Coronary Syndromes
Baldus, S., Heeschen, C., Meinertz, T., Zeiher, A. M., Eiserich, J. P., Münzel, T., Simoons, M. L., & Hamm, C. W. (2003) · Circulation · doi:10.1161/01.cir.0000090690.67322.51 · Cited by 1,013
T he D iagnostic A pplications of S aliva — A R eview
Kaufman, E., & Lamster, I. B. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300209 · Cited by 887
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Gibson, C. M., Murphy, S. A., Rifai, N., McCabe, C., Antman, E. M., Cannon, C. P., & Braunwald, E. (2002) · Circulation · doi:10.1161/01.cir.0000015464.18023.0a · Cited by 735
Salivary Transcriptome Diagnostics for Oral Cancer Detection
Li, Y., St. John, M. A. R., Zhou, X., Kim, Y., Sinha, U., Jordan, R. C. K., Eisele, D., Abemayor, E., Elashoff, D., Park, N.-H., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1167 · Cited by 625
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182882 · Cited by 610
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 474
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Malamud, D. (2011) · Dental Clinics of North America · doi:10.1016/j.cden.2010.08.004 · Cited by 489
Saliva diagnostics – Current views and directions
Kaczor-Urbanowicz, K. E., Martin Carreras-Presas, C., Aro, K., Tu, M., Garcia-Godoy, F., & Wong, D. T. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370216681550 · Cited by 472
Current Developments in Salivary Diagnostics
Miller, C. S., Foley, J. D., Bailey, A. L., Campell, C. L., Humphries, R. L., Christodoulides, N., Floriano, P. N., Simmons, G., Bhagwandin, B., Jacobson, J. W., et al. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.09.68 · Cited by 389
Self-citationThe Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Emerging applications of nanomedicine for the diagnosis and treatment of cardiovascular diseases
Godin, B., Sakamoto, J. H., Serda, R. E., Grattoni, A., Bouamrani, A., & Ferrari, M. (2010) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2010.01.003 · Cited by 236
“Associated to electrocardiogram (ECG) analysis, a saliva-based biomarker test within a lab-on-a-chip platform exceeded the screening capacity of ECG alone, providing a rapid screening for acute myocardial infarction (AMI) patients [52].”
MethodRiis, J. L., Out, D., Dorn, L. D., Beal, S. J., Denson, L. A., Pabst, S., Jaedicke, K., & Granger, D. A. (2014) · Developmental Psychobiology · doi:10.1002/dev.21149 · Cited by 108
Metadata
- Authors
- Floriano, P. N., Christodoulides, N., Miller, C. S., Ebersole, J. L., Spertus, J., Rose, B. G., Kinane, D. F., Novak, M. J., Steinhubl, S., Acosta, S., Mohanty, S., Dharshan, P., Yeh, C.-K., Redding, S., Furmaga, W., & McDevitt, J. T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-01
- Volume
- 55
- Issue
- 8
- Pages
- 1530-1538
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2154600779
- Cited by
- 190
- References
- 37
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.