Activity Assays and Immunoassays for Plasma Renin and Prorenin: Information Provided and Precautions Necessary for Accurate Measurement
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. Content: Renin activity assays and immunoassays provide related but different information. Whereas activity assays measure only active renin, immunoassays measure both active and inhibited renin. Particular care must be taken in the collection and processing of blood samples and in the performance of these assays to avoid errors in renin measurement. Both activity assays and immunoassays are susceptible to renin overestimation due to prorenin activation. In addition, activity assays performed with peptidase inhibitors may overestimate the degree of inhibition of PRA by renin inhibitor therapy. Moreover, immunoassays may overestimate the reactive increase in plasma renin concentration in response to renin inhibitor therapy, owing to the inhibitor promoting conversion of prorenin to an open conformation that is recognized by renin immunoassays. Conclusions: The successful application of renin assays to patient care requires that the clinician and the clinical chemist understand the information provided by these assays and of the precautions necessary to ensure their accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Funder, J. W., Carey, R. M., Fardella, C., Gomez-Sanchez, C. E., Mantero, F., Stowasser, M., Young, W. F., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0104 · Cited by 1,554
Self-citation
Cited by
Funder, J. W., Carey, R. M., Mantero, F., Murad, M. H., Reincke, M., Shibata, H., Stowasser, M., & Young, W. F. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-4061 · Cited by 2,925
“It should be noted that there is poor correlation between DRC and PRA in the range where PRA is 1 ng/mL/h, the domain of major interest in PA screening (221, 222).”
BackgroundSelf-citationHypertension: Renin–Angiotensin–Aldosterone System Alterations
te Riet, L., van Esch, J. H. M., Roks, A. J. M., van den Meiracker, A. H., & Danser, A. H. J. (2015) · Circulation Research · doi:10.1161/circresaha.116.303587 · Cited by 706
Self-citationMulatero, P., Monticone, S., Deinum, J., Amar, L., Prejbisz, A., Zennaro, M.-C., Beuschlein, F., Rossi, G. P., Nishikawa, T., Morganti, A., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002510 · Cited by 317
Self-citationParthasarathy, H. K., Ménard, J., White, W. B., Young, W. F., Williams, G. H., Williams, B., Ruilope, L. M., McInnes, G. T., Connell, J. M., & MacDonald, T. M. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283455ca5 · Cited by 281
Self-citationVaidya, A., Forman, J. P., Hopkins, P. N., Seely, E. W., & Williams, J. S. (2011) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.1177/1470320310391922 · Cited by 93
“Though our study design controlled for many major confounders of the RAS, several other factors that are known (estrogen status, stress, sympathetic nervous system activity) or unknown to affect the RAS may have influenced our measurements [58, 59].”
Background
Metadata
- Authors
- Campbell, D. J., Nussberger, J., Stowasser, M., Danser, A. H. J., Morganti, A., Frandsen, E., & Ménard, J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 867-877
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2162569186
- Cited by
- 187
- References
- 1
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Activity Assays and Immunoassays for Plasma Renin and Prorenin: Information Provided and Precautions Necessary for Accurate Measurement. https://app.cochat.ai/papers/10.1373/clinchem.2008.118000
- The paper
- Campbell, D. J., Nussberger, J., Stowasser, M., Danser, A. H. J., Morganti, A., Frandsen, E., & Ménard, J. (2009). Activity Assays and Immunoassays for Plasma Renin and Prorenin: Information Provided and Precautions Necessary for Accurate Measurement. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.118000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.