Biological and Analytical Variability of a Novel High-Sensitivity Cardiac Troponin T Assay
The DOI matches its Crossref record.
Abstract
Background: High-sensitivity cardiac troponin assays will augment the frequency of increased results, making important the determination of reference change values to distinguish acute from chronic increases. We assessed short- and long-term biological variability of cardiac troponin T (cTnT) in healthy subjects with a novel high-sensitivity (hs) assay. Methods: We collected blood from 20 healthy volunteers at 5 time points for short-term study and biweekly at 4 times from the same volunteers for long-term study. We analyzed serum samples in duplicate with a hscTnT assay on the Roche Modular E170 and computed reference change values (RCVs) for analytical, intraindividual, interindividual, and total change values (CVA, CVI, CVG, and CVT, respectively) and the index of individuality (II). We calculated RCVs by using a log-normal approach, owing to the skewed results of the data. Results: Short- and long-term CVA values were 53.5% and 98%. CVI and CVG were 48.2% and 85.9%, respectively, for short-term studies and 94% and 94% for long-term studies. Mean δ values for the within-day study were 58% and −57.5%, and between-day mean δ values were 103.4% and −87%. Within- and between-day IIs were 0.8 and 0.14, respectively. Conclusions: The biological variation demonstrated with the hscTnT assay is higher than prior data for cardiac troponin I. This may be attributed to differences in biology or assay imprecision at low concentrations. A short-term change (RCV log normal) of 85% and a long-term change of 315% is necessary to define a changing pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
“반면, Table 3은 1개의 연구[36] 외에는 모 두 Wu 등이 초창기에 수집한 것과 동일한[35], 단기변이의 측정에 사용된 검체에서 hs 검사법 5개의 생물학적 변이 특성을 보여주고 있다[35-38].”
How to use high-sensitivity cardiac troponins in acute cardiac care
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs154 · Cited by 784
Self-citationdeFilippi, C. R., de Lemos, J. A., Christenson, R. H., Gottdiener, J. S., Kop, W. J., Zhan, M., & Seliger, S. L. (2010) · JAMA · doi:10.1001/jama.2010.1708 · Cited by 715
Recommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Self-citationTroponin elevation in coronary vs. non-coronary disease
Agewall, S., Giannitsis, E., Jernberg, T., & Katus, H. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq456 · Cited by 592
Metadata
- Authors
- Vasile, V. C., Saenger, A. K., Kroning, J. M., & Jaffe, A. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-07-01
- Volume
- 56
- Issue
- 7
- Pages
- 1086-1090
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1991357520
- Cited by
- 154
- References
- 0
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biological and Analytical Variability of a Novel High-Sensitivity Cardiac Troponin T Assay. https://app.cochat.ai/papers/10.1373/clinchem.2009.140616
- The paper
- Vasile, V. C., Saenger, A. K., Kroning, J. M., & Jaffe, A. S. (2010). Biological and Analytical Variability of a Novel High-Sensitivity Cardiac Troponin T Assay. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.140616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.