Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 784

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

How to use high-sensitivity cardiac troponins in acute cardiac care

Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., Collinson, P., Venge, P., Hasin, Y., Galvani, M., Koenig, W., Hamm, C., Alpert, J. S., Katus, H., Jaffe, A. S., the Study Group on Biomarkers in Cardiology of the ESC Working Group on Acute Cardiac Care·2012·European Heart Journal

Abstract

Recommendations for the use of cardiac troponin (cTn) measurement in acute cardiac care have recently been published.1 Subsequently, a high-sensitivity (hs) cTn T assay was introduced into routine clinical practice.2 This assay, as others, called highly sensitive, permits measurement of cTn concentrations in significant numbers of apparently illness-free individuals. These assays can measure cTn in the single digit range of nanograms per litre (=picograms per millilitre) and some research assays even allow detection of concentrations <1 ng/L.2–4 Thus, they provide a more precise calculation of the 99th percentile of cTn concentration in reference subjects (the recommended upper reference limit [URL]). These assays measure the URL with a coefficient of variation (CV) <10%.2–4 The high precision of hs-cTn assays increases their ability to determine small differences in cTn over time. Many assays currently in use have a CV >10% at the 99th percentile URL limiting that ability.5–7 However, the less precise cTn assays do not cause clinically relevant false-positive diagnosis of acute myocardial infarction (AMI) and a CV <20% at the 99th percentile URL is still considered acceptable.8 We believe that hs-cTn assays, if used appropriately, will improve clinical care. We propose criteria for the clinical interpretation of test results based on the limited evidence available at this time. ‘Sensitive’ and ‘high-sensitive’ are terms often used by manufacturers to describe their assays for marketing purposes. In some cases, it reflects higher sensitivity than former assays developed by the same company, and in other situations it reflects a higher sensitivity than most assays on the market. Although there is still no consensus regarding when the terms ‘sensitive’ and ‘high-sensitive’ should be applied, we advocate that cTn assays should be labelled ‘high-sensitive’ only if they fulfil the analytical criteria suggested by guidelines1,9,10 not only in the research laboratories of the manufacturers but also in routine clinical laboratories.11–19 Often manufacturers' claims for assay precision cannot be achieved in clinical laboratories (see Table 1). It is also important to note that there may be substantial differences between ‘high-sensitivity’ assays. Most present cTn assays do not detect even in 50% of apparently disease-free individuals20 whereas high-sensitivity assays do and with some, detection may be as high as in 90%.4,20,21 In addition, reports for the hs-cTnI Singulex®, the hs-cTnT, and the Abbott® hs-cTnI assays suggest a need for different 99th percentile values in men and women, although that does not seem to be the case with the hs-cTnI Beckman® research assay.2,21–24 Peer-reviewed analytical evaluation data on cardiac troponin assays approved for routine diagnostics In addition, hs-cTnI assays fulfilling the analytical criteria of guidelines have been developed by Beckman®, Nanosphere®, Singulex®, and Siemens®, which are still in the pre-marketing phase but may also become available for routine use subsequently. None of the currently commercially available cTn assays except for the hs-cTnT and the yet to be approved hs-cTnI assay from Abbott Diagnostics meets the proposed criteria for a high-sensitivity assay in routine use. It is important to differentiate between the LoB and the LoD, because these terms are frequently not correctly used in the cTn literature. The LoB is the highest signal in a test which can be expected from a sample without the analyte, in contrast the LoD is the lowest concentration of an analyte in a sample which reliably can be differentiated from a sample without the analyte. The LoD is always higher than the LoB. NA, not available; LoB, lower limit of blank; LoD, lower limit of detection. aBench-top systems suitable for point-of-care (POC) analysis but no hand-held POC devices. bNot approved by the US Food and Drug Administration so far. cMay be approved for routine use in Europe in 2012. Peer-reviewed analytical evaluation data on cardiac troponin assays approved for routine diagnostics In addition, hs-cTnI assays fulfilling the analytical criteria of guidelines have been developed by Beckman®, Nanosphere®, Singulex®, and Siemens®, which are still in the pre-marketing phase but may also become available for routine use subsequently. None of the currently commercially available cTn assays except for the hs-cTnT and the yet to be approved hs-cTnI assay from Abbott Diagnostics meets the proposed criteria for a high-sensitivity assay in routine use. It is important to differentiate between the LoB and the LoD, because these terms are frequently not correctly used in the cTn literature. The LoB is the highest signal in a test which can be expected from a sample without the analyte, in contrast the LoD is the lowest concentration of an analyte in a sample which reliably can be differentiated from a sample without the analyte. The LoD is always higher than the LoB. NA, not available; LoB

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehs154

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 784

Metadata

Authors
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., Collinson, P., Venge, P., Hasin, Y., Galvani, M., Koenig, W., Hamm, C., Alpert, J. S., Katus, H., Jaffe, A. S., & the Study Group on Biomarkers in Cardiology of the ESC Working Group on Acute Cardiac Care
Venue
European Heart Journal
Published
2012-06-21
Volume
33
Issue
18
Pages
2252-2257
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2139243268
Cited by
784
References
1
FWCI
44.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How to use high-sensitivity cardiac troponins in acute cardiac care. https://app.cochat.ai/papers/10.1093/eurheartj/ehs154
The paper
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., Collinson, P., Venge, P., Hasin, Y., Galvani, M., Koenig, W., Hamm, C., Alpert, J. S., Katus, H., Jaffe, A. S., & the Study Group on Biomarkers in Cardiology of the ESC Working Group on Acute Cardiac Care. (2012). How to use high-sensitivity cardiac troponins in acute cardiac care. European Heart Journal. https://doi.org/10.1093/eurheartj/ehs154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.