CoChat

Sources of Variability in Measurements of Cardiac Troponin T in a Community-Based Sample: The Atherosclerosis Risk in Communities Study

Open access
Agarwal, Sunil K, Avery, Christy L, Ballantyne, Christie M, Catellier, Diane, Nambi, Vijay, Saunders, Justin, Sharrett, A Richey, Coresh, Josef, Heiss, Gerardo, Hoogeveen, Ron C · 2011 · Clinical Chemistry
Cited by 88

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Application of cardiac troponin T (cTnT) as a marker of myocyte damage requires knowledge of its measurement variability. Using a highly sensitive assay for measurement, we evaluated the long-term storage stability of plasma cTnT at −70 °C and the sources of cTnT variability. METHODS: Samples from the Atherosclerosis Risk in Communities study collected in 1996–1998 and 2005–2006 were assayed centrally to quantify variability in cTnT attributable to processing (replicates from same blood draw, n = 87), laboratory (replicates after freeze thaw, n = 29), short-term (n = 40) and long-term biological variation (repeat visit, n = 38), and degradation in frozen storage (n = 7677). RESULTS: Approximately 30% of this population-based cohort had cTnT concentrations below the detection limit (3 ng/L). Reliability coefficients for all paired comparisons exceeded 0.93 except for samples drawn 8 years apart (r = 0.36). Sources of cTnT variation (as CVs) were: laboratory, 2.1% and 11.2% in those with and without heart failure, respectively; processing, 18.3%; biological, 16.6% at 6 weeks and 48.4% at 8 years. The reference change value at 6 weeks (68.5%) indicated that 4 samples are needed to determine a homeostatic set point within ±25%. The estimated cTnT degradation rate over the first year in long-term frozen storage was 0.36 ng/L per year. CONCLUSIONS: cTnT was detectable in approximately 70% of community-dwelling middle-aged study participants and stable in −70 °C storage. The variability in cTnT attributable to 1 freeze–thaw cycle is of small magnitude. The observed high laboratory and intraindividual (biological) reliability of cTnT support its use for population-based research, and in clinical settings that rely on classification and serial measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2010.159350

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 88

Metadata

Authors
Agarwal, S. K., Avery, C. L., Ballantyne, C. M., Catellier, D., Nambi, V., Saunders, J., Sharrett, A. R., Coresh, J., Heiss, G., & Hoogeveen, R. C.
Venue
Clinical Chemistry
Published
2011-06-01
Volume
57
Issue
6
Pages
891-897
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2138934576
Cited by
88
References
2
FWCI
5.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sources of Variability in Measurements of Cardiac Troponin T in a Community-Based Sample: The Atherosclerosis Risk in Communities Study. https://app.cochat.ai/papers/10.1373/clinchem.2010.159350
The paper
Agarwal, S. K., Avery, C. L., Ballantyne, C. M., Catellier, D., Nambi, V., Saunders, J., Sharrett, A. R., Coresh, J., Heiss, G., & Hoogeveen, R. C. (2011). Sources of Variability in Measurements of Cardiac Troponin T in a Community-Based Sample: The Atherosclerosis Risk in Communities Study. Clinical Chemistry. https://doi.org/10.1373/clinchem.2010.159350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.