CoChat

Diabetes Antibody Standardization Program: First Proficiency Evaluation of Assays for Autoantibodies to Zinc Transporter 8

Lampasona, Vito, Schlosser, Michael, Mueller, Patricia W, Williams, Alistair JK, Wenzlau, Janet M, Hutton, John C, Achenbach, Peter, Participating Laboratories · 2011 · Clinical Chemistry
Cited by 109

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Zinc transporter 8 (ZnT8) is a recently identified major autoantigen in type 1 diabetes, and autoantibodies to ZnT8 (ZnT8A) are new markers for disease prediction and diagnosis. Here we report the results of the first international proficiency evaluation of ZnT8A assays by the Diabetes Antibody Standardization Program (DASP). METHODS: After a pilot workshop in 2007, an expanded ZnT8A workshop was held in 2009, with 26 participating laboratories from 13 countries submitting results of 63 different assays. ZnT8A levels were measured in coded sera from 50 patients with newly diagnosed type 1 diabetes and 100 blood donor controls. Results were analyzed comparing area under the ROC curve (ROC-AUC), sensitivity adjusted to 95% specificity (AS95), concordance of sample ZnT8A positive or negative designation, and autoantibody levels. RESULTS: ZnT8A radio binding assays (RBAs) based on combined immunoprecipitation of the 2 most frequent ZnT8 COOH-terminal domain polymorphic variants showed a median ROC-AUC of 0.848 [interquartile range (IQR) 0.796–0.878] and a median AS95 of 70% (IQR 60%–72%). These RBAs were more sensitive than assays using as antigen either 1 ZnT8 variant only or chimeric constructs joining NH2- and COOH-terminal domains, assays based on immunoprecipitation and bioluminescent detection, or assays based on immunofluorescent staining of cells transfected with full-length antigen. CONCLUSIONS: The DASP workshop identified immunoprecipitation-based ZnT8A assays and antigen constructs that achieved both a high degree of sensitivity and specificity and were suitable for more widespread clinical application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2011.170662

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 109

Metadata

Authors
Lampasona, V., Schlosser, M., Mueller, P. W., Williams, A. J., Wenzlau, J. M., Hutton, J. C., Achenbach, P., & Laboratories, P.
Venue
Clinical Chemistry
Published
2011-12-01
Volume
57
Issue
12
Pages
1693-1702
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2158409975
Cited by
109
References
10
FWCI
6.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.