CoChat

Harmonization of Glutamic Acid Decarboxylase and Islet Antigen-2 Autoantibody Assays for National Institute of Diabetes and Digestive and Kidney Diseases Consortia

Open access

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

BACKGROUND/RATIONALE: Autoantibodies to islet antigen-2 (IA-2A) and glutamic acid decarboxylase (GADA) are markers for diagnosis, screening, and measuring outcomes in National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) consortia studies. A harmonization program was established to increase comparability of results within and among these studies. METHODS: Large volumes of six working calibrators were prepared from pooled sera with GADA 4.8-493 World Health Organization (WHO) units/ml and IA-2A 2-235 WHO units/ml. Harmonized assay protocols for IA-2A and GADA using (35)S-methionine-labelled in vitro transcribed and translated antigens were developed based on methods in use in three NIDDK laboratories. Antibody thresholds were defined using sera from patients with recent onset type 1 diabetes and healthy controls. To evaluate the impact of the harmonized assay protocol on concordance of IA-2A and GADA results, two laboratories retested stored TEDDY study sera using the harmonized assays. RESULTS: The harmonized assays gave comparable but not identical results in the three laboratories. For IA-2A, using a common threshold of 5 DK units/ml, 549 of 550 control and patient samples were concordantly scored as positive or negative, specificity was greater than 99% with sensitivity 64% in all laboratories. For GADA, using thresholds equivalent to the 97th percentile of 974 control samples in each laboratory, 1051 (97.9%) of 1074 samples were concordant. On the retested TEDDY samples, discordance decreased from 4 to 1.8% for IA-2A (n = 604 samples; P = 0.02) and from 15.4 to 2.7% for GADA (n = 515 samples; P < 0.0001). CONCLUSION: Harmonization of GADA and IA-2A is feasible using large volume working calibrators and common protocols and is an effective approach to ensure consistency in autoantibody measurements.

Overview

Integrity signals

Registry

Crossref · 10.1210/jc.2010-0293

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Cited by

See all 291

Metadata

Authors
Bonifacio, E., Yu, L., Williams, A. K., Eisenbarth, G. S., Bingley, P. J., Marcovina, S. M., Adler, K., Ziegler, A. G., Mueller, P. W., Schatz, D. A., Krischer, J. P., Steffes, M. W., & Akolkar, B.
Affiliations
  • Center for Regenerative Therapies Dresden (DE)
  • University of Colorado Denver (US)
  • Clinical Science at North Bristol (A.K.W., P.J.B.), University of Bristol, Southmead Hospital, Bristol BS10 5NB, United Kingdom
  • Southmead Hospital (GB)
  • University of Washington (US)
  • Institute of Diabetes Research (DE)
  • Centers for Disease Control and Prevention (US)
  • University of Florida (US)
  • University of South Florida (US)
  • University of Minnesota (US)
  • National Institutes of Health (US)
Corresponding author
Bonifacio, Ezio
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2010-07-01
Volume
95
Issue
7
Pages
3360-3367
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1965800980
Cited by
291
References
19
Citations by year
2026: 11 · 2025: 12 · 2024: 15 · 2023: 23 · 2022: 25 · 2021: 24 · 2020: 26 · 2019: 22 · 2018: 19 · 2017: 23 · 2016: 20 · 2015: 19 · 2014: 10 · 2013: 18 · 2012: 12
FWCI
7.37
Type
journal article
Language
en
Open access
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
  • Site cant be reached (submittedVersion)
  • Bristol Research (University of Bristol) (submittedVersion)
Funders
  • National Heart, Lung, and Blood Institute (R01HL61753, R01HL061753, R01HL079611)
  • National Institute of Diabetes and Digestive and Kidney Diseases (DK-63865, UC4DK063821, DK-63821, P30DK057516, DK 63790, P30 DK 57516, DK63863, DK63861, DK63836, UC4DK063829, U01DK063829, U01DK063790, DK-63829)
  • National Center for Research Resources (M01RR000051)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
Keywords
glutamic acid decarboxylase antibodies, type 1 diabetes, assay concordance, TEDDY study
MeSH terms
Academies and Institutes, Adolescent, Adult, Autoantibodies, Glutamate Decarboxylase, Humans, Radioligand Assay, Reference Values, Sensitivity and Specificity, Receptor-Like Protein Tyrosine Phosphatases, Class 8

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Harmonization of Glutamic Acid Decarboxylase and Islet Antigen-2 Autoantibody Assays for National Institute of Diabetes and Digestive and Kidney Diseases Consortia. https://app.cochat.ai/papers/10.1210/jc.2010-0293
The paper
Bonifacio, E., Yu, L., Williams, A. K., Eisenbarth, G. S., Bingley, P. J., Marcovina, S. M., Adler, K., Ziegler, A. G., Mueller, P. W., Schatz, D. A., Krischer, J. P., Steffes, M. W., & Akolkar, B. (2010). Harmonization of Glutamic Acid Decarboxylase and Islet Antigen-2 Autoantibody Assays for National Institute of Diabetes and Digestive and Kidney Diseases Consortia. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2010-0293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.