CoChat

Two-Step Biochemical Differential Diagnosis of Classic 21-Hydroxylase Deficiency and Cytochrome P450 Oxidoreductase Deficiency in Japanese Infants by GC-MS Measurement of Urinary Pregnanetriolone/ Tetrahydroxycortisone Ratio and 11β-Hydroxyandrosterone

Koyama, Yuhei, Homma, Keiko, Fukami, Maki, Miwa, Masayuki, Ikeda, Kazushige, Ogata, Tsutomu, Hasegawa, Tomonobu, Murata, Mitsuru · 2012 · Clinical Chemistry
Cited by 30

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The clinical differential diagnosis of classic 21-hydroxylase deficiency (C21OHD) and cytochrome P450 oxidoreductase deficiency (PORD) is sometimes difficult, because both deficiencies can have similar phenotypes and high blood concentrations of 17α-hydroxyprogesterone (17OHP). The objective of this study was to identify biochemical markers for the differential diagnosis of C21OHD, PORD, and transient hyper 17α-hydroxyprogesteronemia (TH17OHP) in Japanese newborns. We established a 2-step biochemical differential diagnosis of C21OHD and PORD. METHODS: We recruited 29 infants with C21OHD, 9 with PORD, and 67 with TH17OHP, and 1341 control infants. All were Japanese and between 0 and 180 days old; none received glucocorticoid treatment before urine sampling. We measured urinary pregnanetriolone (Ptl), the cortisol metabolites 5α- and 5β-tetrahydrocortisone (sum of these metabolites termed THEs), and metabolites of 3 steroids, namely dehydroepiandrosterone, androstenedione (AD4), and 11β-hydroxyandrostenedione (11OHAD4) by GC-MS. RESULTS: At a cutoff of 0.020, the ratio of Ptl to THEs differentiated C21OHD and PORD from TH17OHP and controls with no overlap. Among metabolites of DHEA, AD4, and 11OHAD4, only 11β-hydroxyandrosterone (11HA), a metabolite of 11OHAD4, showed no overlap between C21OHD and PORD at a cutoff of 0.35 mg/g creatinine. CONCLUSIONS: A specific cutoff for the ratio of Ptl to THEs can differentiate C21OHD and PORD from TH17OHP and controls. Additionally, the use of a specific cutoff of 11HA can distinguish between C21OHD and PORD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2011.173286

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 30

Metadata

Authors
Koyama, Y., Homma, K., Fukami, M., Miwa, M., Ikeda, K., Ogata, T., Hasegawa, T., & Murata, M.
Venue
Clinical Chemistry
Published
2012-04-01
Volume
58
Issue
4
Pages
741-747
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2146118298
Cited by
30
References
11
FWCI
1.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two-Step Biochemical Differential Diagnosis of Classic 21-Hydroxylase Deficiency and Cytochrome P450 Oxidoreductase Deficiency in Japanese Infants by GC-MS Measurement of Urinary Pregnanetriolone/ Tetrahydroxycortisone Ratio and 11β-Hydroxyandrosterone. https://app.cochat.ai/papers/10.1373/clinchem.2011.173286
The paper
Koyama, Y., Homma, K., Fukami, M., Miwa, M., Ikeda, K., Ogata, T., Hasegawa, T., & Murata, M. (2012). Two-Step Biochemical Differential Diagnosis of Classic 21-Hydroxylase Deficiency and Cytochrome P450 Oxidoreductase Deficiency in Japanese Infants by GC-MS Measurement of Urinary Pregnanetriolone/ Tetrahydroxycortisone Ratio and 11β-Hydroxyandrosterone. Clinical Chemistry. https://doi.org/10.1373/clinchem.2011.173286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.