CoChat

Associations of Alternative Markers of Glycemia with Hemoglobin A1c and Fasting Glucose

Open access
Juraschek, Stephen P, Steffes, Michael W, Selvin, Elizabeth · 2012 · Clinical Chemistry
Cited by 94

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: 1,5-Anhydroglucitol (1,5-AG), fructosamine, and glycated albumin are of increasing interest as alternative measures of hyperglycemia. We characterize the associations of these nontraditional glycemic markers with hemoglobin A1c (Hb A1c) and fasting glucose and assess their ability to identify people with diabetes. METHODS: We conducted a cross-sectional comparison of 1,5-AG, fructosamine, and glycated albumin with Hb A1c and fasting glucose measurements in 1719 participants from the Atherosclerosis Risk in Communities Study. We evaluated nonlinear relationships using R2 and F-statistics. Performance for identification of cases of diabetes was determined using the area under the curve (AUC). Diabetes was defined by Hb A1c ≥6.5%, fasting glucose ≥126 mg/dL (≥6.99 mmol/L), and/or a self-reported history of diagnosed diabetes. RESULTS: Median values of Hb A1c and fasting glucose were 5.8% and 109 mg/dL (6.05 mmol/L), respectively; 17.3% of the study population had diagnosed diabetes. Glycated albumin, fructosamine, and 1,5-AG were more strongly correlated with Hb A1c compared with fasting glucose (all P values <0.05). Nonlinear models provided the best fit for describing the relationships of the alternative markers to Hb A1c. When diabetes was defined by an Hb A1c ≥6.5%, fructosamine (AUC 0.83; 95% CI, 0.79–0.87) and glycated albumin (AUC 0.87; 95% CI, 0.83–0.90) performed comparably to fasting glucose (AUC 0.83; 95% CI, 0.79–0.87), while 1,5-AG performed worse (AUC 0.74; 95% CI, 0.69–0.78) for identifying cases of undiagnosed diabetes. CONCLUSIONS: Fructosamine and glycated albumin may be useful adjuncts to Hb A1c and fasting glucose. Future studies should examine these markers in situations in which fasting glucose or Hb A1c measurements are invalid or not available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2012.188367

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Juraschek, S. P., Steffes, M. W., & Selvin, E.
Venue
Clinical Chemistry
Published
2012-12-01
Volume
58
Issue
12
Pages
1648-1655
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2096202086
Cited by
94
References
4
FWCI
6.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.