The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
The Digital MIQE Guidelines: Minimum Information for Publication of Quantitative Digital PCR Experiments
Open accessAbstract
There is growing interest in digital PCR (dPCR) because technological progress makes it a practical and increasingly affordable technology. dPCR allows the precise quantification of nucleic acids, facilitating the measurement of small percentage differences and quantification of rare variants. dPCR may also be more reproducible and less susceptible to inhibition than quantitative real-time PCR (qPCR). Consequently, dPCR has the potential to have a substantial impact on research as well as diagnostic applications. However, as with qPCR, the ability to perform robust meaningful experiments requires careful design and adequate controls. To assist independent evaluation of experimental data, comprehensive disclosure of all relevant experimental details is required. To facilitate this process we present the Minimum Information for Publication of Quantitative Digital PCR Experiments guidelines. This report addresses known requirements for dPCR that have already been identified during this early stage of its development and commercial implementation. Adoption of these guidelines by the scientific community will help to standardize experimental protocols, maximize efficient utilization of resources, and enhance the impact of this promising new technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“As a first step toward this, guidelines for digital MIQE have been proposed (16).”
From Analysis of Extracellular RNA by Digital PCR (2014) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationHigh-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Quantitative real-time RT-PCR – a perspective
Bustin, S. A., Benes, V, Nolan, T., & Pfaffl, M. W. (2005) · Journal of Molecular Endocrinology · doi:10.1677/jme.1.01755 · Cited by 1,321
Self-citationEvaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2011) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,089
Self-citationGenome instability: a mechanistic view of its causes and consequences
Aguilera, A., & Gómez‐González, B. (2008) · Nature Reviews Genetics · doi:10.1038/nrg2268 · Cited by 830
Quantitation of targets for PCR by use of limiting dilution.
Sykes, P. J., Neoh, S. H., Brisco, M. J., Hughes, E., Condon, J. C., & Morley, A. A. (1992) · PubMed · Cited by 618
Quantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J., Corre, D. L., Mažutis, L., Salem, C. B., Millot, F., Harrak, A. E., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 536
Whale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453
Self-citationDigital PCR for the molecular detection of fetal chromosomal aneuploidy
Lo, Y. M. D., Lun, F. M. F., Chan, K. C. A., Tsui, N. B. Y., Chong, K. C., Lau, T. K., Leung, T. Y., Zee, B. C.-Y., Cantor, C. R., & Chiu, R. W. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705765104 · Cited by 434
Cited by
Sorted by citations
An overview of microRNAs: Biology, functions, therapeutics, and analysis methods
Saliminejad, K., Khorram Khorshid, H. R., Soleymani Fard, S., & Ghaffari, S. H. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.27486 · Cited by 1,872
Extracellular miRNAs: From Biomarkers to Mediators of Physiology and Disease
Mori, M. A., Ludwig, R. G., García-Martín, R., Brandão, B. B., & Kahn, C. R. (2019) · Cell Metabolism · doi:10.1016/j.cmet.2019.07.011 · Cited by 990
Clonal haematopoiesis harbouring AML-associated mutations is ubiquitous in healthy adults
Young, A. L., Challen, G. A., Birmann, B. M., & Druley, T. E. (2016) · Nature Communications · doi:10.1038/ncomms12484 · Cited by 692
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Reporting the limits of detection and quantification for environmental DNA assays
Klymus, K. E., Merkes, C. M., Allison, M. J., Goldberg, C. S., Helbing, C. C., Hunter, M. E., Jackson, C. A., Lance, R. F., Mangan, A. M., Monroe, E. M., et al. (2019) · Environmental DNA · doi:10.1002/edn3.29 · Cited by 590
Metadata
- Authors
- Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., Pfaffl, M. W., Shipley, G. L., Vandesompele, J., Wittwer, C. T., & Bustin, S. A.
- Affiliations
- LGC (GB)
- Genomics Core Facility, EMBL Heidelberg, Heidelberg, Germany
- National Measurement Institute (AU)
- University College London (GB)
- National Institute of Standards and Technology (US)
- Ghent University Hospital (BE)
- Czech Academy of Sciences, Institute of Biotechnology (CZ)
- Sequenom Center for Molecular Medicine, San Diego, CA
- Sigma Custom Products, Haverhill, Suffolk, UK
- Physiology Weihenstephan, Center of Life and Food Sciences Weihenstephan, Germany
- Shipley Consulting, LLC, Houston, TX
- University of Utah (US)
- Anglia Ruskin University (GB)
- Corresponding author
- Huggett, Jim F
- ORCID
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-06-01
- Volume
- 59
- Issue
- 6
- Pages
- 892-902
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2099066165
- Cited by
- 859
- References
- 45
- Citations by year
- 2026: 47 · 2025: 47 · 2024: 50 · 2023: 56 · 2022: 78 · 2021: 95 · 2020: 96 · 2019: 67 · 2018: 71 · 2017: 59 · 2016: 74 · 2015: 58 · 2014: 48 · 2013: 11
- FWCI
- 28.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Anglia Ruskin Research Online (Anglia Ruskin University) (submittedVersion)
- ASEP (submittedVersion, public-domain)
- UCL Discovery (University College London) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- UK National Measurement System (AV0Z50520701, GACR GA P303/10/1338)
- BioFire Diagnostics
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Keywords
- digital PCR, MIQE guidelines, reporting guidelines, experimental reproducibility, nucleic acid quantification, experimental design, control, standardization of protocols
- MeSH terms
- Computers, Guidelines as Topic, Real-Time Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review