CoChat

Activity-Based Concept to Screen Biological Matrices for Opiates and (Synthetic) Opioids

Cannaert, Annelies, Vasudevan, Lakshmi, Friscia, Melissa, Mohr, Amanda L A, Wille, Sarah M R, Stove, Christophe P · 2018 · Clinical Chemistry
Cited by 54

The DOI matches its Crossref record.

Abstract

BACKGROUND: Detection of new highly potent synthetic opioids is challenging as new compounds enter the market. Here we present a novel screening method for the detection of opiates and (synthetic) opioids based on their activity. METHODS: A cell-based system was set up in which activation of the μ-opioid receptor (MOR) led to recruitment of β-arrestin 2, resulting in functional complementation of a split NanoLuc luciferase and allowing readout via bioluminescence. Assay performance was evaluated on 107 postmortem blood samples. Blood (500 μL) was extracted via solid-phase extraction. Following evaporation and reconstitution in 100 μL of Opti-MEM® I, 20 μL was analyzed in the bioassay. RESULTS: In 8 samples containing synthetic opioids, in which no positive signal was obtained in the bioassay, quadrupole time-of-flight mass spectrometry revealed the MOR antagonist naloxone, which can prevent receptor activation. Hence, further evaluation did not include these samples. For U-47700 (74.5–547 ng/mL) and furanyl fentanyl (<1–38.8 ng/mL), detection was 100% (8/8) for U-47700 and 95% (21/22) for furanyl fentanyl. An analytical specificity of 93% (55/59) was obtained for the opioid negatives. From an additional 10 samples found to contain other opioids, 5 were correctly scored positive. Nondetection in 5 cases could be explained by very low concentrations (<1 ng/mL alfentanil/sufentanil) or presence of inactive enantiomers. CONCLUSIONS: The MOR reporter assay allows rapid identification of opioid activity in blood. Although the cooccurrence of opioid antagonists is currently a limitation, the bioassay's high detection capability, specificity, and untargeted nature may render it a useful first-line screening tool to investigate potential opioid intoxications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2018.289496

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Cannaert, A., Vasudevan, L., Friscia, M., Mohr, A. L. A., Wille, S. M. R., & Stove, C. P.
Venue
Clinical Chemistry
Published
2018-08-01
Volume
64
Issue
8
Pages
1221-1229
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2804132168
Cited by
54
References
0
FWCI
19.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Activity-Based Concept to Screen Biological Matrices for Opiates and (Synthetic) Opioids. https://app.cochat.ai/papers/10.1373/clinchem.2018.289496
The paper
Cannaert, A., Vasudevan, L., Friscia, M., Mohr, A. L. A., Wille, S. M. R., & Stove, C. P. (2018). Activity-Based Concept to Screen Biological Matrices for Opiates and (Synthetic) Opioids. Clinical Chemistry. https://doi.org/10.1373/clinchem.2018.289496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.