CoChat

Fixed and Autoadjusting Continuous Positive Airway Pressure Treatments Are Not Similar in Reducing Cardiovascular Risk Factors in Patients With Obstructive Sleep Apnea

The DOI matches its Crossref record; 39 of the 41 references it cites were found in a registry or an index.

Abstract

Background A strong association between obstructive sleep apnea (OSA) and the risk for cardiovascular and cerebrovascular diseases has been reported. Continuous positive airway pressure (CPAP) is the first-line therapy for OSA, able not only to reduce daytime sleepiness but also to improve cardiovascular and metabolic outcomes. Autoadjusting CPAP (APAP), an alternative treatment to CPAP, can reduce OSA symptoms while increasing long-term CPAP compliance without the high costs of CPAP titration. However, no data are available on the effects of APAP on cardiovascular risk factors Methods We performed standard full polysomnography; obtained plasma levels of glucose, insulin, and C-reactive protein (CRP); and measured systolic BP (SBP) and diastolic BP (DBP) in 31 patients with newly diagnosed, severe OSA. After standard CPAP titration, all subjects were randomized to CPAP or APAP treatment. Measurements were obtained at baseline and after 3 months of treatment. Results The two groups were similar in terms of age, sex, body mass index (BMI), and severity of OSA. SBP, DBP, heart rate (HR), homeostasis model assessment index (HOMA-IR), and CRP were similar in the two groups. After 3 months of treatment, BMI, HR, and compliance to therapy were also comparable. OSA indexes were significantly reduced in both groups. Significant reductions in SBP, DBP, and HOMA-IR were observed in the CPAP group but not in the APAP group, while CRP plasma levels were similarly reduced. Conclusions Our…

Overview

Integrity signals

Registry

Crossref · 10.1378/chest.06-2192

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Cited by

See all 130

Metadata

Authors
Patruno, V., Aiolfi, S., Costantino, G., Murgia, R., Selmi, C., Malliani, A., & Montano, N.
Affiliations
University of Milan (IT)
Corresponding author
Montano, Nicola
Venue
Chest
Publisher
Elsevier BV
Published
2007-05
Volume
131
Issue
5
Pages
1393-1399
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2163979524
Cited by
130
References
41
Citations by year
2026: 2 · 2025: 5 · 2023: 5 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 8 · 2018: 6 · 2017: 7 · 2016: 5 · 2015: 8 · 2014: 6 · 2013: 9 · 2012: 15
FWCI
7.12
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Funders
ResMed
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, continuous positive airway pressure, cardiovascular risk factors, blood pressure, insulin resistance, C-reactive protein, CPAP adherence, CPAP titration, HOMA, heart rate
MeSH terms
Adult, Blood Glucose, Blood Pressure, C-Reactive Protein, Cardiovascular Diseases, Female, Heart Rate, Humans, Inflammation, Insulin Resistance, Male, Middle Aged, Risk Factors, Time Factors, Body Mass Index, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fixed and Autoadjusting Continuous Positive Airway Pressure Treatments Are Not Similar in Reducing Cardiovascular Risk Factors in Patients With Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1378/chest.06-2192
The paper
Patruno, V., Aiolfi, S., Costantino, G., Murgia, R., Selmi, C., Malliani, A., & Montano, N. (2007). Fixed and Autoadjusting Continuous Positive Airway Pressure Treatments Are Not Similar in Reducing Cardiovascular Risk Factors in Patients With Obstructive Sleep Apnea. Chest. https://doi.org/10.1378/chest.06-2192

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.