Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ultrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery

Lerolle, Nicolas, Guérot, Emmanuel, Dimassi, Saoussen, Zegdi, Rachid, Faisy, Christophe, Fagon, Jean-Yves, Diehl, Jean-Luc·2009·Chest

Abstract

BACKGROUND Severe diaphragmatic dysfunction can prolong mechanical ventilation after cardiac surgery. An ultrasonographic criterion for diagnosing severe diaphragmatic dysfunction defined by a reference technique such as transdiaphragmatic pressure measurements has never been determined. METHODS Twenty-eight patients requiring mechanical ventilation > 7 days postoperatively were studied. Esophageal and gastric pressures were measured to calculate transdiaphragmatic pressure during maximal inspiratory effort and the Gilbert index, which evaluates the diaphragm contribution to respiratory pressure swings during quiet ventilation. Ultrasonography allowed measuring right and left hemidiaphragmatic excursions during maximal inspiratory effort. Best E is the greatest positive value from either hemidiaphragm. Twenty cardiac surgery patients with uncomplicated postoperative course were also evaluated with ultrasonography preoperatively and postoperatively. Measurements were performed in semirecumbent position. RESULTS Transdiaphragmatic pressure during maximal inspiratory effort was below normal value in 27 of the 28 patients receiving prolonged mechanical ventilation (median, 39 cm H(2)O; interquartile range [IQR] 28 cm H(2)O). Eight patients had Gilbert indexes <or= 0 indicating severe diaphragmatic dysfunction. Best E was lower in patients with Gilbert index <or= 0 than > 0 (30 mm; IQR, 10 mm; vs 19 mm; IQR, 7 mm, respectively; p = 0.001). Best E < 25 mm had a positive likelihood ratio of 6.7 (95% confidence interval [CI], 2.4 to 19) and a negative likelihood ratio of 0 (95% CI, 0 to 1.1) for having a Gilbert index <or= 0. None of the patients with uncomplicated course had Best E < 25 mm either preoperatively or postoperatively. CONCLUSIONS Ultrasonographic-based determination of hemidiaphragm excursions in patients requiring prolonged mechanical ventilation after cardiac surgery may help identify those with and without severe diaphragmatic dysfunction as defined by the Gilbert index.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1378/chest.08-1531

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 238

Metadata

Authors
Lerolle, N., Guérot, E., Dimassi, S., Zegdi, R., Faisy, C., Fagon, J.-Y., & Diehl, J.-L.
Venue
Chest
Publisher
Elsevier BV
Published
2009-02
Volume
135
Issue
2
Pages
401-407
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2021925293
Cited by
238
References
1
FWCI
2.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery. https://app.cochat.ai/papers/10.1378/chest.08-1531
The paper
Lerolle, N., Guérot, E., Dimassi, S., Zegdi, R., Faisy, C., Fagon, J.-Y., & Diehl, J.-L. (2009). Ultrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery. Chest. https://doi.org/10.1378/chest.08-1531

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.