Ultrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND Severe diaphragmatic dysfunction can prolong mechanical ventilation after cardiac surgery. An ultrasonographic criterion for diagnosing severe diaphragmatic dysfunction defined by a reference technique such as transdiaphragmatic pressure measurements has never been determined. METHODS Twenty-eight patients requiring mechanical ventilation > 7 days postoperatively were studied. Esophageal and gastric pressures were measured to calculate transdiaphragmatic pressure during maximal inspiratory effort and the Gilbert index, which evaluates the diaphragm contribution to respiratory pressure swings during quiet ventilation. Ultrasonography allowed measuring right and left hemidiaphragmatic excursions during maximal inspiratory effort. Best E is the greatest positive value from either hemidiaphragm. Twenty cardiac surgery patients with uncomplicated postoperative course were also evaluated with ultrasonography preoperatively and postoperatively. Measurements were performed in semirecumbent position. RESULTS Transdiaphragmatic pressure during maximal inspiratory effort was below normal value in 27 of the 28 patients receiving prolonged mechanical ventilation (median, 39 cm H(2)O; interquartile range [IQR] 28 cm H(2)O). Eight patients had Gilbert indexes <or= 0 indicating severe diaphragmatic dysfunction. Best E was lower in patients with Gilbert index <or= 0 than > 0 (30 mm; IQR, 10 mm; vs 19 mm; IQR, 7 mm, respectively; p = 0.001). Best E < 25 mm had a positive likelihood ratio of 6.7 (95% confidence interval [CI], 2.4 to 19) and a negative likelihood ratio of 0 (95% CI, 0 to 1.1) for having a Gilbert index <or= 0. None of the patients with uncomplicated course had Best E < 25 mm either preoperatively or postoperatively. CONCLUSIONS Ultrasonographic-based determination of hemidiaphragm excursions in patients requiring prolonged mechanical ventilation after cardiac surgery may help identify those with and without severe diaphragmatic dysfunction as defined by the Gilbert index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Lung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
BLUE-Protocol and FALLS-Protocol
Lichtenstein, D. A. (2015) · Chest · doi:10.1378/chest.14-1313 · Cited by 691
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
Self-citationDiaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*
Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182266408 · Cited by 550
Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Self-citationCritical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Zambon, M., Greco, M., Bocchino, S., Cabrini, L., Beccaria, P. F., & Zangrillo, A. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4524-z · Cited by 386
Neuromuscular ultrasound for evaluation of the diaphragm
Sarwal, A., Walker, F. O., & Cartwright, M. S. (2013) · Muscle & Nerve · doi:10.1002/mus.23671 · Cited by 350
Umbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
New International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
Tuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Metadata
- Authors
- Lerolle, N., Guérot, E., Dimassi, S., Zegdi, R., Faisy, C., Fagon, J.-Y., & Diehl, J.-L.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 135
- Issue
- 2
- Pages
- 401-407
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W2021925293
- Cited by
- 238
- References
- 2
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.