The DOI matches its Crossref record.
Efficacy and Safety of Low Dose Recombinant Tissue-Type Plasminogen Activator for the Treatment of Acute Pulmonary Thromboembolism
Open accessAbstract
Background Optimal dosing of the recombinant tissue-type plasminogen activator (rt-PA) is important in treating pulmonary thromboembolism (PTE). The aim of this study was to compare the efficacy and safety of a 50 mg/2 h rt-PA regimen with a 100 mg/2 h rt-PA regimen in patients with acute PTE. Methods A prospective, randomized, multicenter trial was conducted in which 118 patients with acute PTE and either hemodynamic instability or massive pulmonary artery obstruction were randomly assigned to receive a treatment regiment of either rt-PA at 50 mg/2 h (n = 65) or 100 mg/2 h (n = 53). The efficacy was determined by observing the improvements of right ventricular dysfunctions (RVDs) on echocardiograms, lung perfusion defects on ventilation perfusion lung scans, and pulmonary artery obstructions on CT angiograms. The adverse events, including death, bleeding, and PTE recurrence, were also evaluated. Results Progressive improvements in RVDs, lung perfusion defects, and pulmonary artery obstructions were found to be similarly significant in both treatment groups. This is true for patients with either hemodynamic instability or massive pulmonary artery obstruction. Three (6%) patients in the rt-PA 100 mg/2 h group and one (2%) in the rt-PA 50 mg/2 h group died as the result of either PTE or bleeding. Importantly, the 50 mg/2 h rt-PA regimen resulted in less bleeding tendency than the 100 mg/2 h regimen (3% vs 10%), especially in patients with a body weight < 65 kg (14.8% vs 41.2%, P = .049). No fatal recurrent PTE was found in either group. Conclusions Compared with the 100 mg/2 h regimen, the 50 mg/2 h rt-PA regimen exhibits similar efficacy and perhaps better safety in patients with acute PTE. These findings support the notion that optimizing rt-PA dosing is worthwhile when treating patients with PTE. Trial registration clinicaltrials.gov; Identifier: NCT00781378
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Metadata
- Authors
- Wang, C., Zhai, Z., Yang, Y., Wu, Q., Cheng, Z., Liang, L., Dai, H., Huang, K., Lu, W., Zhang, Z., Cheng, X., & Shen, Y. H.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 137
- Issue
- 2
- Pages
- 254-262
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W2169548288
- Cited by
- 289
- References
- 0
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and Safety of Low Dose Recombinant Tissue-Type Plasminogen Activator for the Treatment of Acute Pulmonary Thromboembolism. https://app.cochat.ai/papers/10.1378/chest.09-0765
- The paper
- Wang, C., Zhai, Z., Yang, Y., Wu, Q., Cheng, Z., Liang, L., Dai, H., Huang, K., Lu, W., Zhang, Z., Cheng, X., & Shen, Y. H. (2010). Efficacy and Safety of Low Dose Recombinant Tissue-Type Plasminogen Activator for the Treatment of Acute Pulmonary Thromboembolism. Chest. https://doi.org/10.1378/chest.09-0765
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.