CoChat

Efficacy of an Adjustable Oral Appliance and Comparison With Continuous Positive Airway Pressure for the Treatment of Obstructive Sleep Apnea Syndrome

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Background We sought to establish the efficacy of an adjustable oral appliance (aOA) in the largest patient population studied to date, to our knowledge, and to provide a comparison with continuous positive airway pressure (CPAP). Methods We conducted a retrospective analysis of patients using an aOA. Results of overnight polysomnography with aOA titration were evaluated and compared with CPAP. Predictors of a successful aOA titration were determined using a multivariate logistic regression model. Results A total of 497 patients were given an aOA during the specified time period. The aOA reduced the mean apnea-hypopnea index (AHI) to 8.4 ± 11.4, and 70.3%, 47.6%, and 41.4% of patients with mild, moderate, and severe disease achieved an AHI Conclusions In comparison with past reports, more patients in our study achieved an AHI < 5 using an aOA. The aOA is comparable to CPAP for patients with mild disease, whereas CPAP is superior for patients with moderate to severe disease. A lower AHI was the only predictor of a successful aOA titration.

Overview

Integrity signals

Registry

Crossref · 10.1378/chest.10-2851

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Cited by

See all 125

Metadata

Authors
Holley, A. B., Lettieri, C. J., & Shah, A. A.
Affiliations
  • Walter Reed National Military Medical Center (US)
  • Madigan Army Medical Center (US)
Corresponding author
Holley, Aaron B.
Venue
Chest
Publisher
Elsevier BV
Published
2011-12
Volume
140
Issue
6
Pages
1511-1516
ISSN
0012-3692 (ISSN-L)
OpenAlex
W1989915001
Cited by
125
References
28
Citations by year
2026: 1 · 2025: 2 · 2024: 4 · 2023: 7 · 2022: 7 · 2021: 3 · 2020: 10 · 2019: 3 · 2018: 11 · 2017: 14 · 2016: 15 · 2015: 16 · 2014: 19 · 2013: 6 · 2012: 7
FWCI
6.98
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
Keywords
obstructive sleep apnea, continuous positive airway pressure, apnea-hypopnea index, Epworth Sleepiness Scale, treatment efficacy, predictors of treatment success, disease severity
MeSH terms
Adult, Analysis of Variance, Female, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Patient Compliance, Retrospective Studies, Severity of Illness Index, Cohort Studies, Multivariate Analysis, Logistic Models, Treatment Outcome, Patient Satisfaction, Polysomnography, Mandibular Advancement, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of an Adjustable Oral Appliance and Comparison With Continuous Positive Airway Pressure for the Treatment of Obstructive Sleep Apnea Syndrome. https://app.cochat.ai/papers/10.1378/chest.10-2851
The paper
Holley, A. B., Lettieri, C. J., & Shah, A. A. (2011). Efficacy of an Adjustable Oral Appliance and Comparison With Continuous Positive Airway Pressure for the Treatment of Obstructive Sleep Apnea Syndrome. Chest. https://doi.org/10.1378/chest.10-2851

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.