MESAM 4: An Ambulatory Device for the Detection of Patients at Risk for Obstructive Sleep Apnea Syndrome (OSAS)
Open accessThe DOI matches its Crossref record.
Abstract
A validation study was performed on the MESAM 4, a digital recording device developed to monitor oxygen saturation, heart rate (HR), snoring, and body position in order to screen subjects for obstructive sleep apnea syndrome (OSAS). MESAM 4 recordings were scored with the computer-based automatic scoring system provided with the equipment. Nocturnal polysomnography (PSG) and MESAM 4 recordings were run simultaneously on 56 subjects presenting with any type of sleep complaint, including those secondary to OSAS. Patients were assigned to one room by hospital administration and were monitored consecutively. The polygraphic equipment and MESAM 4 equipment were placed on the subjects by separate teams. Records of PSG and MESAM 4 were analyzed in double-blind fashion. With the MESAM 4 computerized analysis, three indices based on SaO2 (ODI), on heart rate (HVI), and on snoring (ISI) were obtained, and the number of abnormal respiratory events occurring during the time selected for analysis (TAT) were determined. Polysomnographic records were scored by 30-s epochs following the American Sleep Disorders Association standards for sleep states and stages and for sleep-related events, including sleep apneas, hypopneas, and periodic leg movements. Following independent scoring, 26 subjects were identified with OSAS by PSG, while MESAM 4 identified 25 subjects with OSAS using oxygen algorithm; all had a respiratory disturbance index greater than or equal to 10 with PSG. Results of each polysomnogram and each MESAM 4 analysis were compared. With the polysomnogram used as a standard, the degree of error for each variable with the MESAM 4 was calculated. Specificity and sensitivity of the most accurate index of the MESAM 4, the ODI, were 97 percent and 92 percent, respectively. The other two indices, HVI and ISI, were less accurate: specificity and sensitivity were 32 percent and 58 percent for HVI and 27 percent and 96 percent for ISI. Nevertheless, a combination of all three indices (ODI, HVI, ISI) would have prevented the two false-positive cases we observed. The results of this validation study show that MESAM 4 can be helpful to general practitioners, clinicians, and epidemiologists as a low-cost screening device for subjects with OSAS and habitual snoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DURÁN, J., ESNAOLA, S., RUBIO, R., & IZTUETA, Á. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2005065 · Cited by 1,407
“The MESAM IV (Medizintechnik für Artz und Patient, Munich, Germany) is a four-channel digital recording system that has been previously validated (17, 18).”
MethodA Cause of Excessive Daytime Sleepiness
Guilleminault, C., Stoohs, R., Clerk, A., Cetel, M., & Maistros, P. (1993) · Chest · doi:10.1378/chest.104.3.781 · Cited by 897
Self-citationSleep Apnea as an Independent Risk Factor for All-Cause Mortality: The Busselton Health Study
(2008) · Sleep · doi:10.5665/sleep/31.8.1079 · Cited by 889
Martin, J. L., & Hakim, A. D. (2011) · Chest · doi:10.1378/chest.10-1872 · Cited by 603
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Marshall, N. S., Wong, K. K. H., Cullen, S. R. J., Knuiman, M. W., & Grunstein, R. R. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3600 · Cited by 513
“18,29,30 Underpowering is probably the biggest limitation to the Busselton Sleep Cohort, particularly with only 18 people in the highest exposure category.”
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Prevalence of Sleep-Disordered Breathing in Ages 40–64 Years: A Population-Based Survey
Kripke, D. F., Ancoli-Israel, S., Klauber, M. R., Wingard, D. L., Mason, W. J., & Mullaney, D. J. (1997) · Sleep · doi:10.1093/sleep/20.1.65 · Cited by 361
The effect of antihypertensive agents on sleep apnea: protocol for a randomized controlled trial
Cichelero, F. T., Martinez, D., Fuchs, S. C., Gus, M., Moreira, L. B., & Fuchs, F. D. (2014) · Trials · doi:10.1186/1745-6215-15-1 · Cited by 301
Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Vazquez, J.-C. (2000) · Thorax · doi:10.1136/thorax.55.4.302 · Cited by 254
Sleep-related Breathing Disorder Is an Independent Risk Factor for Systemic Hypertension
GROTE, L., PLOCH, T., HEITMANN, J., KNAACK, L., PENZEL, T., & PETER, J. H. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.9811054 · Cited by 232
Obstructive Sleep Apnea as a Risk Marker in Coronary Artery Disease
Schäfer, H., Koehler, U., Ewig, S., Hasper, E., Tasci, S., & Lüderitz, B. (1999) · Cardiology · doi:10.1159/000006952 · Cited by 221
Castronovo, V., Zucconi, M., Nosetti, L., Marazzini, C., Hensley, M., Veglia, F., Nespoli, L., & Ferini-Strambi, L. (2003) · The Journal of Pediatrics · doi:10.1067/mpd.2003.118 · Cited by 204
Marshall, N. S., Wong, K. K. H., Phillips, C. L., Liu, P. Y., Knuiman, M. W., & Grunstein, R. R. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27387 · Cited by 201
Risk of traffic accidents in patients with sleep-disordered breathing: reduction with nasal CPAP
Cassel, W., Ploch, T., Becker, C., Dugnus, D., Peter, J., & von Wichert, P. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09122606 · Cited by 201
“MESAM IV [20–22] recordings were then performed on all patients and, according to their results, the necessity for full polysomnographic recordings in the sleep laboratory was subsequently determined.”
MethodAccuracy of Oximetry for Detection of Respiratory Disturbances in Sleep Apnea Syndrome
Lévy, P., Louis Pépin, J., Deschaux-Blanc, C., Paramelle, B., & Brambilla, C. (1996) · Chest · doi:10.1378/chest.109.2.395 · Cited by 188
Home testing for pediatric obstructive sleep apnea syndrome secondary to adenotonsillar hypertrophy
Jacob, S. V., Morielli, A., Mograss, M. A., Ducharme, F. M., Schloss, M. D., & Brouillette, R. T. (1995) · Pediatric Pulmonology · doi:10.1002/ppul.1950200407 · Cited by 162
The Effect of Electrical Stimulation on Obstructive Sleep Apnea Syndrome
Guilleminault, C., Powell, N., Bowman, B., & Stoohs, R. (1995) · Chest · doi:10.1378/chest.107.1.67 · Cited by 112
Self-citationHome sleep studies in the assessment of sleep apnea/hypopnea syndrome
Golpe, R., Jime´nez, A., & Carpizo, R. (2002) · Chest · doi:10.1378/chest.122.4.1156 · Cited by 109
Long‐Term Results of Uvulopalatopharyngoplasty for Obstructive Sleep Apnea Syndrome
Boot, H., van Wegen, R., Poublon, R. M. L., Bogaard, J. M., Schmitz, P. I. M., & van der Meché, F. G. A. (2000) · The Laryngoscope · doi:10.1097/00005537-200003000-00027 · Cited by 95
Laser-assisted uvulopalatoplasty for snoring: does it meet the expectations?
Larrosa, F., Hernandez, L., Morello, A., Ballester, E., Quinto, L., & Montserrat, J. M. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00082903 · Cited by 76
Patel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Stoohs, R., & Guilleminault, C.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1992-05
- Volume
- 101
- Issue
- 5
- Pages
- 1221-1227
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W1975040776
- Cited by
- 152
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.