Dyspnea Ratings for Prescribing Exercise Intensity in Patients With COPD
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVE: We tested the hypothesis that patients with COPD can use dyspnea ratings obtained from a prior graded exercise test as a target to reliably produce specific exercise intensities. DESIGN: Four visits over a 7-week period. SETTING: Pulmonary function and cardiorespiratory exercise laboratory at a university hospital. PATIENTS: Fifteen symptomatic patients with stable COPD. Age was 68 +/- 7 (mean +/- SD) years. FEV1 was 1.12 +/- 0.22 L (45 +/- 8% predicted). INTERVENTIONS: At each visit, patients estimated the heaviness of weights to evaluate their magnitude estimation of a nonrespiratory task; after pulmonary function testing was completed, patients were tested on the cycle ergometer. At estimation trial 1 (day 0), patients estimated the intensity of dyspnea using the 0 to 10 category-ratio scale during an incremental exercise test. Estimation trial 2 (day 5 to 7) was the same as the previous trial. At production trials 1 (day 10 to 14) and 2 (day 40 to 44), patients were instructed to produce specific intensities of dyspnea (ie, dyspnea targets) at 50% and at anaerobic threshold (AT) or 80% of peak oxygen consumption (Vo2) as calculated from results at estimation trial 2. MEASUREMENTS AND RESULTS: Lung function was stable at all visits. Dyspnea ratings were 1.8 +/- 0.9 (range, 1 to 3) at 50% of peak Vo2 and 5.5 +/- 1.5 (range, 4 to 8) at AT/80% of peak Vo2 (17.0 +/- 3.4 mL/kg/min) at estimation trial 2. The individual percent changes in Vo2 at the lower dyspnea target were 12 +/- 19% and 11 +/- 19% for production trials 1 and 2, respectively, compared with estimation trial 2. At the higher dyspnea target, the corresponding individual percent changes in Vo2 were -4 +/- 9% and -7 +/- 11%, respectively. For all 15 patients, there were borderline statistical differences for the Vo2 values at the lower (p = 0.04 and p = 0.07) and at the higher (p = 0.04 for each production trial) dyspnea targets for production trials 1 and 2 compared with estimation trial 2. Two patients showed 50% or greater variability in the calculated exponent for magnitude estimation of weights. In a subgroup analysis of the 13 patients with reproducible magnitude estimation of the heaviness of weights, there were no significant differences in Vo2 for the two production trials compared with estimation trial 2 at both exercise intensities. CONCLUSIONS: Dyspnea ratings obtained from an incremental exercise test can be used as a target for patients with COPD to regulate/monitor the intensity of exercise training. The ability of patients with COPD to achieve a desired Vo2 based on an individual dyspnea target was generally more accurate at the higher exercise level (AT/80% of peak Vo2) compared with the lower intensity (50% of peak Vo2). Acceptable accuracy was maintained over a 5-week time period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
Ries, A. L., Kaplan, R. M., Limberg, T. M., & Prewitt, L. M. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-11-199506010-00003 · Cited by 903
Using perceived exertion to prescribe and monitor exercise training heart rate
Dishman, R., Patton, R., Smith, J., Weinberg, R., & Jackson, A. (1987) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025657 · Cited by 60
Cited by
Spruit, M. A., Singh, S. J., Garvey, C., ZuWallack, R., Nici, L., Rochester, C., Hill, K., Holland, A. E., Lareau, S. C., Man, W. D.-C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201309-1634st · Cited by 3,938
American Thoracic Society/European Respiratory Society statement on pulmonary rehabilitation
Nici, L., Donner, C., Wouters, E., Zuwallack, R., Ambrosino, N., Bourbeau, J., Carone, M., Celli, B., Engelen, M., Fahy, B., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200508-1211st · Cited by 1,966
Pulmonary Rehabilitation in Chronic Obstructive Pulmonary Disease
Troosters, T., Casaburi, R., Gosselink, R., & Decramer, M. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1109so · Cited by 649
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.5.ats2-99 · Cited by 425
Are Patients With COPD More Active After Pulmonary Rehabilitation?
Pitta, F., Troosters, T., Probst, V. S., Langer, D., Decramer, M., & Gosselink, R. (2008) · Chest · doi:10.1378/chest.07-2655 · Cited by 300
Supplemental oxygen during pulmonary rehabilitation in patients with COPD with exercise hypoxaemia
Garrod, R. (2000) · Thorax · doi:10.1136/thorax.55.7.539 · Cited by 259
Garvey, C., Bayles, M. P., Hamm, L. F., Hill, K., Holland, A., Limberg, T. M., & Spruit, M. A. (2016) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000171 · Cited by 241
O'DONNELL, D. E., McGUIRE, M., SAMIS, L., & WEBB, K. A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.5.9708010 · Cited by 206
“The use of targeted Borg dyspnea ratings ( 29 ) in conjunction with HR monitoring, proved reliable in ensuring that patients trained at the highest tolerable ventilation (and O2) for the longest possible duration (Figure 1). With physiologic data obtained from the cycle exercise tests, we calculated that using this Bo…”
MethodSpruit, M. A., Janssen, P. P., Willemsen, S. C. P., Hochstenbag, M. M. H., & Wouters, E. F. M. (2006) · Lung Cancer · doi:10.1016/j.lungcan.2006.01.003 · Cited by 193
Respiratory and Limb Muscle Dysfunction in COPD
Barreiro, E., & Gea, J. (2015) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2014.974737 · Cited by 168
“Moreover, a Rating of Perceived Exertion of 12 to 14 and a Borg dyspnea or fatigue score of 4 to 6 are considered to be a target training intensity (102).”
BackgroundSugawara, K., Takahashi, H., Kasai, C., Kiyokawa, N., Watanabe, T., Fujii, S., Kashiwagura, T., Honma, M., Satake, M., & Shioya, T. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.05.008 · Cited by 131
Metadata
- Authors
- Horowitz, M. B., Littenberg, B., & Mahler, D. A.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1996-05
- Volume
- 109
- Issue
- 5
- Pages
- 1169-1175
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W1966443963
- Cited by
- 163
- References
- 3
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.