Using Perceived Exertion to Prescribe and Monitor Exercise Training Heart Rate
The DOI matches its Crossref record.
Abstract
We examined whether feedback of heart rate (HR) or HR combined with ratings of perceived exertion (RPE and HR) during a graded exercise test (GXT) and during early trials of field training would reduce the errors commonly seen when training heart rate range (THR) is self-monitored by participants. Asymptomatic males (n = 24) were tested on a Balke treadmill protocol in a randomized, between-groups design under control conditions or conditions where feedback about HR or HR combined with RPE were given as age-predicted THR was approximated. This was followed on alternating days by three field trials of an 800-m jog where errors between prescribed and attained THR were fed back to each subject. A priori 95% confidence intervals for the first field trial showed that signed (algebraic) error for the HR combined with RPE condition (+3 bts/min) was less than for controls (+23.5 bts/min). Feedback of HR alone was no different from the control condition. All groups showed increased accuracy (P less than .05) by the third field trial [absolute error: T1 (18 bts/min) to T3 (9.6 bts/min); signed error: T1 (+14 bts/min) to T3 (+4 bts/min)]. Our results suggest feedback of HR combined with RPE during a GXT may reduce an overshoot in THR during the first of subsequent exercise sessions. Feedback of HR alone appeared sufficient to further reduce THR errors after a third exercise session in the field. The procedures used may have practical importance for sedentary, unfit, or diseased individuals where conservative HR prescriptions are desirable but electronic monitoring is not feasible or cost effective.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Use of %HRR is well established as an alternative metric for exercise intensity because the value is generally linear and proportional to V .O 2 R (25,28).”
From Ventilatory Threshold Related to VO2reserve, Heart Rate Reserve, and Rating of Perceived Exertion in a Large Varied Sample (2023) · cites this paper as [28]
Citations
Cites
Still being checked.
Cited by
Pollock, M. L., Gaesser, G. A., Butcher, J. D., Despr??s, J.-P., Dishman, R. K., Franklin, B. A., & Garber, C. E. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199806000-00032 · Cited by 3,051
Self-citationBuchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0029-x · Cited by 1,490
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Buchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0066-5 · Cited by 869
MONITORING EXERCISE INTENSITY DURING RESISTANCE TRAINING USING THE SESSION RPE SCALE
DAY, M. L., MCGUIGAN, M. R., BRICE, G., & FOSTER, C. (2004) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200405000-00027 · Cited by 567
Metadata
- Authors
- Dishman, R., Patton, R., Smith, J., Weinberg, R., & Jackson, A.
- Affiliations
- University of Georgia (US)
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1987-06
- Volume
- 08
- Issue
- 03
- Pages
- 208-213
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2049192025
- Cited by
- 60
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 1
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- training heart rate, heart rate monitoring, rating of perceived exertion, heart rate feedback, exercise prescription, incremental exercise test
- MeSH terms
- Adult, Exercise Test, Physical Exertion, Feedback, Heart Rate, Humans, Male, Perception
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Perceived Exertion to Prescribe and Monitor Exercise Training Heart Rate. https://app.cochat.ai/papers/10.1055/s-2008-1025657
- The paper
- Dishman, R., Patton, R., Smith, J., Weinberg, R., & Jackson, A. (1987). Using Perceived Exertion to Prescribe and Monitor Exercise Training Heart Rate. International Journal of Sports Medicine. https://doi.org/10.1055/s-2008-1025657
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.