Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

A Prospective, Randomized Comparison of an In-Line Heat Moisture Exchange Filter and Heated Wire Humidifiers

Open access
Kirton, Orlando C., DeHaven, Bryan, Morgan, Joseph, Morejon, Orlando, Civetta, Joseph·1997·Chest

Abstract

PURPOSE: To compare the performance of an in-line heat moisture exchanging filter (HMEF) (Pall BB-100; Pall Corporation; East Hills, NY) to a conventional heated wire humidifier (H-wH) (Marquest Medical Products Inc., Englewood, Colo) in the mechanical ventilator circuit on the incidence of ventilator-associated pneumonia (VAP) and the rate of endotracheal tube occlusion. METHODS: This report describes a prospective, randomized trial of 280 consecutive trauma patients in a 20-bed trauma ICU (TICU). All intubated patients not ventilated elsewhere in the medical center prior to their TICU admission were randomized to either an in-line HMEF or a H-wH in the breathing circuit. Ventilator circuits were changed routinely every 7 days, and closed system suction catheters were changed every 3 days. HMEFs were changed every 24 h, or more frequently if necessary. A specific endotracheal tube suction and lavage protocol was not employed. Patients were dropped from the HMEF group if the filter was changed more than three times a day or the patient was placed on a regimen of ultra high-frequency ventilation. The Centers for Disease Control and Prevention (CDC) criteria for diagnosis of pneumonia were used; early-onset, community-acquired pneumonia was defined if CDC criteria were met in < or =3 days, and late-onset, hospital-acquired pneumonia was defined if criteria were met in >3 days. Laboratory and chest radiograph interpretation were blinded. RESULTS: The patient ages ranged from 15 to 95 years in the HMEF group and 16 to 87 years in the H-wH group (p=not significant), with a mean age of 46 years and 48 years, respectively. The male to female ratio ranged between 78 to 82%/22 to 18%, respectively, and 55% of all admissions were related to blunt trauma, 40% secondary to penetrating trauma, and 5% to major burns. There was no difference in Injury Severity Score (ISS) between the two groups. Moreover, there was no significant difference in mean ISS among those who did not develop pneumonia and those patients who developed either early-onset, community-acquired or late-onset, hospital-acquired pneumonia. The HMEF nosocomial VAP rate was 6% compared to 16% for the H-wH group (p<0.05), and total ventilator circuit costs (per group) were reduced. There were no differences in duration of ventilation (mean+/-SD) if the patient did not develop pneumonia or if the patient developed an early-onset, community-acquired or a late-onset, hospital-acquired pneumonia. Moreover, total TICU days were reduced in the HMEF group. In addition, the incidence of partial endotracheal tube occlusion was not significantly different between the H-wH and the HMEF groups. CONCLUSIONS: The HMEF used in this study reduced the incidence of late-onset, hospital-acquired VAP, but not early-onset, community-acquired VAP, compared to the conventional H-wH circuit. This was associated with a significant reduction in total ICU stay. Disposable ventilator circuit costs in the HMEF group were reduced compared to the H-wH group in whom circuit changes occurred at 7-day intervals. CLINICAL IMPLICATIONS: The use of the HMEF is a cost-effective clinical practice associated with fewer late-onset, hospital-acquired VAPs, and should result in improved resource allocation and utilization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1378/chest.112.4.1055

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Kirton, O. C., DeHaven, B., Morgan, J., Morejon, O., & Civetta, J.
Venue
Chest
Publisher
Elsevier BV
Published
1997-10
Volume
112
Issue
4
Pages
1055-1059
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2033069458
Cited by
191
References
0
FWCI
9.69
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Prospective, Randomized Comparison of an In-Line Heat Moisture Exchange Filter and Heated Wire Humidifiers. https://app.cochat.ai/papers/10.1378/chest.112.4.1055
The paper
Kirton, O. C., DeHaven, B., Morgan, J., Morejon, O., & Civetta, J. (1997). A Prospective, Randomized Comparison of an In-Line Heat Moisture Exchange Filter and Heated Wire Humidifiers. Chest. https://doi.org/10.1378/chest.112.4.1055

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.