Accuracy of an Infrared Tympanic Thermometer
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The use of infrared thermometry to measure temperatures in hospitalized patients is increasing. Although infrared thermometers have been proven to be accurate when they are used by well-trained personnel, no previous studies have examined their accuracy during routine hospital use. OBJECTIVE: To determine the accuracy and observer variability of temperatures measured with an infrared tympanic thermometer (TT). DESIGN: Prospective, observational study. SETTING: ICUs of a 300-bed teaching community hospital. PATIENTS: Fifty-one critically ill patients. MEASUREMENTS: The mean of three tympanic temperatures measured with the infrared TT (tempTTs) was compared to temperatures simultaneously measured with the thermistor of right heart catheters and rectal mercury thermometers for the following three groups of observers who had been certified in the use of the infrared TT: a single critical care nurse (CCN)/educator (Ed); CCNs, and floor nurses (FNs)/clinical care practitioners (CCPs). RESULTS: Two rounds of measurements were given to 51 patients by 153 observers. Temperatures of the pulmonary artery (PA) measured with the thermistor of right heart catheters (tempPAs) ranged from 96.5 to 102.6 degrees F, with a mean (-/+ SD) of 99.3+/-1.1 degrees F. The intraobserver variabilities (correlation coefficients) of the tempTTs ranged from 0.90 for those measured by FNs/CCPs, to 0.92 for those measured by CCNs, to 0.98 for those measured by the CCN/Ed. Accuracy, arbitrarily defined as within a deviation of -/+0.5 degrees F of the tempPA, was 100% for the rectal mercury thermometer and 98.0% for the infrared TT when used by the CCN/Ed. The accuracy of the infrared TT was 80% when measured by CCNs and 61% when measured by FNs/CCPs. Differences between tempPAs and tempTTs measured by the CCN/Ed ranged from 0 to 0.7 degrees F, with a mean of 0.2 degrees F. Similarly, differences between tempPAs and tempTTs measured by CCNs ranged from 0 to 2.4 degrees F, with a mean difference of 0.3 degrees F. However, differences between tempPAs and tempTTs measured by FNs/CCPs ranged from 0 to 3.0 degrees F, with a mean of 0.6 degrees F (greater differences than those obtained by the CCNs; p < 0.01). The accuracy of rectal mercury thermometry was 100%. If a temperature > or = 101.0 degrees F had been considered as the threshold at which a fever is present, and if the mean of three measurements had been used to designate temperature, workups that were either inappropriately performed or omitted would have resulted from 2% of tempTTs measured by the CCN/Ed, 1% of those measured by CCNs, and 4% of those measured by FNs/CCPs. CONCLUSION: When used properly, both tympanic and rectal thermometry are very accurate. However, the infrared TT produced measurements that were both less accurate and less reproducible when used by nurses who routinely used it in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Lim, C. L., Byrne, C., & Lee, J. K. (2008) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v37n4p347 · Cited by 373
Core Temperature Measurement: Methods and Current Insights
Moran, D. S., & Mendal, L. (2002) · Sports Medicine · doi:10.2165/00007256-200232140-00001 · Cited by 275
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Evaluation of the Temple Touch Pro, a Novel Noninvasive Core-Temperature Monitoring System
Evron, S., Weissman, A., Toivis, V., Shahaf, D. B., You, J., Sessler, D. I., & Ezri, T. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001695 · Cited by 38
Heat Impacts on Work, Human Performance, and Daily Life
Kjellstrom, T., Lemke, B., Matthias Otto, P., Hyatt, O. M., Briggs, D. J., & Freyberg, C. A. (2015) · Climate Change and Public Health · doi:10.1093/med/9780190202453.003.0004 · Cited by 9
Metadata
- Authors
- Amoateng-Adjepong, Y., Del Mundo, J., & Manthous, C. A.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 115
- Issue
- 4
- Pages
- 1002-1005
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W2073686852
- Cited by
- 72
- References
- 0
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.