The DOI matches its Crossref record.
Immunolabeling for Electron Microscopy
Abstract
The protocols in this chapter concern postembedding immunolabeling for transmission electron microscopy; other schedules, such as pre-embedding methods, frozen tissue processes, and procedures for scanning electron microscopy, can be found elsewhere (1). In principle, immunolabeling at the electron microscope (EM) level follows the same precepts as immunolabeling at the light microscope level; in tissues or cells, the location of an antigen of interest is identified by a specific antibody, and must be visualized appropriately for investigation. Electron microscopy permits us to distinguish subcellu-lar organelles, and therefore ultrastructural localization of antigen position. At the EM level, however, the "visualizing step" needs to be provided by an electron-dense entity, most often a heavy metal, which reflects incident electrons; this is in contrast to the final step of light microscope level techniques, in which the final reaction product is sought to be colored (and where there is an element of choice of which color to use). Tissue processing for EM is considerably more severe than that for light microscopy, and thus maintenance of antigenicity in tissue is more taxing. Before immunolabeling for electron microscopy can be fruitful, the first step is to ensure that the antigen of interest is present (or is still present) in the tissue; this is done by performing a thorough procedure at the light microscope level on wax-embedded sections. Once a positive result has been obtained, studies can progress to the ultrastructural level. If the presence of an antigen cannot be demonstrated in a wax-embedded block, it will not be demonstrable in a resin-embedded EM block of the same tissue. In such a case, pre-embedding and frozen tissue techniques can be of use at both light and electron microscope levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of catalase in rat heart mitochondria.
Radi, R., Turrens, J. F., Chang, L. Y., Bush, K. M., Crapo, J. D., & Freeman, B. A. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)54740-2 · Cited by 573
Application of cryoultramicrotomy to immunocytochemistry
Tokuyasu, K. T. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb02772.x · Cited by 512
An Electrochemical Metalloimmunoassay Based on a Colloidal Gold Label
Dequaire, M., Degrand, C., & Limoges, B. (2000) · Analytical Chemistry · doi:10.1021/ac000781m · Cited by 379
Moro, L., Dolce, L., Cabodi, S., Bergatto, E., Erba, E. B., Smeriglio, M., Turco, E., Retta, S. F., Giuffrida, M. G., Venturino, M., et al. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m109101200 · Cited by 377
Vaccine Potential of the Neisseria meningitidis 2086 Lipoprotein
Fletcher, L. D., Bernfield, L., Barniak, V., Farley, J. E., Howell, A., Knauf, M., Ooi, P., Smith, R. P., Weise, P., Wetherell, M., et al. (2004) · Infection and Immunity · doi:10.1128/iai.72.4.2088-2100.2004 · Cited by 332
Metadata
- Authors
- Sarraf, C. E.
- Venue
- Methods in Molecular Medicine
- Publisher
- Humana Press
- Published
- 2000
- Volume
- 40
- Pages
- 439-452
- ISSN
- 1543-1894 (ISSN-L)
- 1940-6037
- OpenAlex
- W61893175
- Cited by
- 217
- References
- 0
- FWCI
- 10.87
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immunolabeling for Electron Microscopy. https://app.cochat.ai/papers/10.1385/1-59259-076-4:439
- The paper
- Sarraf, C. E. (2000). Immunolabeling for Electron Microscopy. Methods in Molecular Medicine. https://doi.org/10.1385/1-59259-076-4%3A439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.