Protein Carbonyl Measurement by ELISA
The DOI matches its Crossref record.
Abstract
Protein carbonyls are formed by a variety of oxidative mechanisms and are sensitive indices of oxidative injury (). The conventional assay for protein carbonyls is a colorimetric procedure that measures binding of dinitrophenylhydrazine (DNP) (,). Protein-bound DNP can also be measured with increased sensitivity by enzyme-linked immunosorbent assay (ELISA) (,). Samples containing protein are reacted with DNP, then the protein is nonspecifically adsorbed to an ELISA plate. Unconjugated DNP and nonprotein constituents are easily washed away and give minimal interference. The adsorbed protein is probed with a commercial biotinylated anti-DNP antibody followed by streptavidin-linked horseradish peroxidase. Absorbances are related to a standard curve prepared of serum albumin containing increasing proportions of hypochlorous acid (HOCl)- oxidized protein that is calibrated colorimetrically. This method requires only microgram quantities of protein and avoids the high and sometimes variable blanks owing to unbound DNP that are limitations for the colorimetric method (,). We have found it to be highly sensitive and discriminatory in analyzing plasma and lung aspirates from both critically ill adult patients and premature infants (,), and others have used it for cell extracts (). Results correlate well with the colorimetric assay. Absolute values can differ between the two assays and each method is best suited for comparing samples using a standard procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Halliwell, B., & Whiteman, M. (2004) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0705776 · Cited by 2,238
“Carbonyls can be readily measured spectrophotometrically and by ELISA techniques (Buss & Winterbourn, 2002; Levine, 2002), and tissue or plasma levels have been shown to be elevated in many human diseases (reviewed by Dalle-Donne et al., 2003).”
BackgroundThe role of reactive oxygen and antioxidant species in periodontal tissue destruction
Chapple, I. L. C., & Matthews, J. B. (2007) · Periodontology 2000 · doi:10.1111/j.1600-0757.2006.00178.x · Cited by 936
Protein carbonylation as a major hallmark of oxidative damage: Update of analytical strategies
Fedorova, M., Bollineni, R. C., & Hoffmann, R. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21381 · Cited by 516
NADPH Oxidase Mediates Hypersomnolence and Brain Oxidative Injury in a Murine Model of Sleep Apnea
Zhan, G., Serrano, F., Fenik, P., Hsu, R., Kong, L., Pratico, D., Klann, E., & Veasey, S. C. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200504-581oc · Cited by 264
Systemic oxidative stress in classic Rett syndrome
De Felice, C., Ciccoli, L., Leoncini, S., Signorini, C., Rossi, M., Vannuccini, L., Guazzi, G., Latini, G., Comporti, M., Valacchi, G., et al. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.05.016 · Cited by 148
Metadata
- Authors
- Buss, I. H., & Winterbourn, C. C.
- Venue
- Oxidative Stress Biomarkers and Antioxidant Protocols
- Publisher
- Humana Press
- Published
- 2003-11-15
- Volume
- 186
- Pages
- 123-128
- OpenAlex
- W2400107462
- Cited by
- 39
- References
- 0
- FWCI
- 6.79
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein Carbonyl Measurement by ELISA. https://app.cochat.ai/papers/10.1385/1-59259-173-6:123
- The paper
- Buss, I. H., & Winterbourn, C. C. (2003). Protein Carbonyl Measurement by ELISA. Oxidative Stress Biomarkers and Antioxidant Protocols. https://doi.org/10.1385/1-59259-173-6%3A123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.