Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

High Accuracy in Classifying Endoscopic Severity in Ulcerative Colitis Using Convolutional Neural Network

Lo, Bobby, Liu, ZhuoYuan, Bendtsen, Flemming, Igel, Christian, Vind, Ida, Burisch, Johan · 2022 · American Journal of Gastroenterology

Abstract

Introduction: The evaluation of endoscopic disease severity is a crucial component in managing patients with ulcerative colitis (UC). However, endoscopic assessment suffers from substantial intraobserver and interobserver variations, limiting the reliability of individual assessments. Therefore, we aimed to develop a deep learning model capable of distinguishing active from healed mucosa and differentiating between different endoscopic disease severity degrees. Methods: One thousand four hundred eighty-four unique endoscopic images from 467 patients were extracted for classification. Two experts classified all images independently of one another according to the Mayo endoscopic subscore (MES). In cases of disagreement, a third expert classified the images. Different convolutional neural networks were considered for automatically classifying UC severity. Five-fold cross-validation was used to develop and select the final model. Afterward, unseen test data sets were used for model evaluation. Results: In the most challenging task—distinguishing between all categories of MES—our final model achieved a test accuracy of 0.84. When evaluating this model on the binary tasks of distinguishing MES 0 vs 1–3 and 0–1 vs 2–3, it achieved accuracies of 0.94 and 0.93 and areas under the receiver operating characteristic curves of 0.997 and 0.998, respectively. Discussion: We have developed a highly accurate, new, automated way of evaluating endoscopic images from patients with UC. We have demonstrated how our deep learning model is capable of distinguishing between all 4 MES levels of activity. This new automated approach may optimize and standardize the evaluation of disease severity measured by the MES across centers no matter the level of medical expertise.

Overview

Integrity signals

Registry

Crossref · 10.14309/ajg.0000000000001904

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Cited by

See all 29

Metadata

Authors
Lo, B., Liu, Z., Bendtsen, F., Igel, C., Vind, I., & Burisch, J.
Affiliations
  • Hvidovre Hospital (DK)
  • University of Copenhagen (DK)
Corresponding author
Lo, Bobby
Venue
American Journal of Gastroenterology
Published
2022-07-15
Volume
117
Issue
10
Pages
1648-1654
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W4285803981
Cited by
29
References
29
Citations by year
2026: 3 · 2025: 9 · 2024: 11 · 2023: 6
FWCI
3.92
Type
journal article
Language
en
Open access
closed
Locations
  • The American Journal of Gastroenterology (publishedVersion)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion)
Topics
  • Health Sciences › Medicine › Gastroenterology › Inflammatory Bowel Disease
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
Keywords
ulcerative colitis, Mayo endoscopic subscore, convolutional neural networks, mucosal healing, interobserver variability, deep learning
MeSH terms
Colitis, Ulcerative, Colonoscopy, Humans, Intestinal Mucosa, Severity of Illness Index, Reproducibility of Results, Neural Networks, Computer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Accuracy in Classifying Endoscopic Severity in Ulcerative Colitis Using Convolutional Neural Network. https://app.cochat.ai/papers/10.14309/ajg.0000000000001904
The paper
Lo, B., Liu, Z., Bendtsen, F., Igel, C., Vind, I., & Burisch, J. (2022). High Accuracy in Classifying Endoscopic Severity in Ulcerative Colitis Using Convolutional Neural Network. American Journal of Gastroenterology. https://doi.org/10.14309/ajg.0000000000001904

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.