Counting particles in tissue sections: choices of methods and importance of calibration to minimize biases.
Open accessThe DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Investigators must choose between counting methods to quantify microscopic particles in tissues. The conventional profile-based ("model-based" or "2D-") counting methods have been criticized for their potential biases due to assumptions about shapes, sizes, and orientation of particles when converting profile counts into cell numbers. New stereological methods ("design-based" or "3D-") methods such as the optical disector or physical disector were initially introduced as being inherently unbiased. Recent calibration analyses and comparisons of results from different investigators have revealed the potential for significant biases in the most efficient and most frequently used design-based method, the optical disector. This review aims to objectively assess the strengths and limitations of current profile- and disector-based cell counting methods by examination of studies in which these methods have been calibrated against the "gold-standard", counts obtained by 3-dimensional reconstruction of serial sections. Advantages and disadvantages of each counting method and the associated embedding and sectioning techniques are compared and frequent mistakes and pitfalls of each technique are discussed. The importance of a calibration step for each technique is emphasized, and a protocol is provided for a quick and simple calibration by a "sampling" 3-D reconstruction of limited serial sections. Trends in the usage of counting methods are analyzed in four major journals. It is hoped that this review will be helpful, for both investigators and manuscript reviewers, in clarifying some of the contentious issues in the choice and implementation of appropriate methods for particle counting in tissue sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUNDERSEN, H. J. G., BENDTSEN, T. F., KORBO, L., MARCUSSEN, N., MØLLER, A., NIELSEN, K., NYENGAARD, J. R., PAKKENBERG, B., SØRENSEN, F. B., VESTERBY, A., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb05320.x · Cited by 2,929
Cited by
von Bartheld, C. S., Bahney, J., & Herculano‐Houzel, S. (2016) · Journal of Comparative Neurology · doi:10.1002/cne.24040 · Cited by 1,063
“…have recommended calibration of both methods against the ultimate standard, i.e., 3D serial section reconstructions of an entire region or a sample thereof (Coggeshall et al., 1990; Hatton and von Bartheld, 1999; von Bartheld, 2001, 2002; Williams et al., 2003; Kaplan et al., 2010).”
BackgroundMethodInfluentialDesign-based stereology in neuroscience
Schmitz, C., & Hof, P. R. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.050 · Cited by 681
Stereological tools in biomedical research
Mandarim-de-Lacerda, C. A. (2003) · Anais da Academia Brasileira de Ciências · doi:10.1590/s0001-37652003000400006 · Cited by 595
Implications of p75NTR for dentate gyrus morphology and hippocampus-related behavior revisited
Dokter, M., Busch, R., Poser, R., Vogt, M. A., von Bohlen und Halbach, V., Gass, P., Unsicker, K., & von Bohlen und Halbach, O. (2015) · Brain Structure and Function · doi:10.1007/s00429-014-0737-5 · Cited by 31
“This method renders biases within the range of the optical dissector by taking into account that the particles counted are small compared with the section thickness (von Bartheld 2002). No guard Brain Struct Funct (2015) 220:1449–1462 1451”
MethodTian, Y., Johnson, G. A., Williams, R. W., & White, L. E. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1223226 · Cited by 9
Metadata
- Authors
- von Bartheld, C. S.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2002-04-01
- Volume
- 17
- Issue
- 2
- Pages
- 639-48
- OpenAlex
- W2409226654
- Cited by
- 90
- References
- 1
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Counting particles in tissue sections: choices of methods and importance of calibration to minimize biases. https://app.cochat.ai/papers/10.14670/hh-17.639
- The paper
- von Bartheld, C. S. (2002). Counting particles in tissue sections: choices of methods and importance of calibration to minimize biases. PubMed. https://doi.org/10.14670/hh-17.639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.