Cited by 16Manufacturing Process and OptimizationMechanical Behavior of CompositesComposite Structure Analysis and Optimization

A Methodological Approach for the Design of Composite Tanks Produced by Filament Winding

Open access
Landi, Daniele, Vita, Alessio, Borriello, Samir, Scafa, Marina, Germani, Michele·2020·Computer-Aided Design and Applications

Abstract

Sports equipment design is a young and evolving engineering discipline focused on the best simultaneous optimization of user and product as a system.In motorsports, in particular, the final performance during a race depends on many parameters related to the vehicle, circuit, weather, and tyres and the personal feelings of every single driver.Top teams in high-tech categories can invest huge amounts of money in developing simulators, but such economic commitment is not sustainable for all those teams that operate in minor but very popular categories, such as karts or mini-motorcycles.In these fields, the most common design approach is trial and error on physical prototypes.Such an approach leads to high costs, long optimization times, poor innovation, and inefficient management of the design knowledge.The present paper proposes a driver centred methodology for the design of an innovative mini racing motorcycle frame.It consists of two main phases: the drivers' feelings translation into engineering requirements and constraints, and the exploration of the design solution space.Expected effects of the application of the proposed methodology are an overall increase in the degree of innovation, time compression, and cost reduction during the development process, with a significant impact on the competitiveness of small racing teams in minor categories.

Integrity signals

Registry

Crossref · 10.14733/cadaps.2020.1229-1240

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Standard H2 storage tanks operate at 350-700 bar and have not yet reached the DOE storage targets of 6.5 wt% or 0.050 kgH2/L for on-board H2 storage.

    “Standard H2 storage tanks are used at an operating pressure of 350–700 bar and have not yet reached the storage gravimetric/volumetric target of 6.5 wt % or 0.050 kgH2/L for the desired driving range (the Department of Energy (DOE) targets for on-board H2 storage).33−38”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Landi, D., Vita, A., Borriello, S., Scafa, M., & Germani, M.
Venue
Computer-Aided Design and Applications
Published
2020-02-26
Volume
17
Issue
6
Pages
1229-1240
ISSN
1686-4360 (ISSN-L)
OpenAlex
W2946468039
Cited by
16
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 1 · 2021: 3 · 2020: 1
FWCI
1.44
Type
journal article
Language
en
Open access
Locations
Computer-Aided Design and Applications (publishedVersion)
Topics
  • Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Manufacturing Process and Optimization
  • Physical Sciences › Engineering › Mechanics of Materials › Mechanical Behavior of Composites
  • Physical Sciences › Engineering › Mechanics of Materials › Composite Structure Analysis and Optimization
Keywords
composite tanks, filament winding, design methodology, fiber-reinforced composites

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review