CoChat

Near-infrared spectroscopy of superficial and deep rectus femoris reveals markedly different exercise response to superficial vastus lateralis

Open access
Koga, Shunsaku, Okushima, Dai, Barstow, Thomas J., Rossiter, Harry B., Kondo, Narihiko, Poole, David C. · 2017 · Physiological Reports
Cited by 36

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

To date our knowledge of skeletal muscle deoxygenation as measured by near-infrared spectroscopy (NIRS) is predicated almost exclusively on sampling of superficial muscle(s), most commonly the vastus lateralis (VL-s). Recently developed high power NIRS facilitates simultaneous sampling of deep (i.e., rectus femoris, RF-d) and superficial muscles of RF (RF-s) and VL-s. Because deeper muscle is more oxidative with greater capillarity and sustains higher blood flows than superficial muscle, we used time-resolved NIRS to test the hypotheses that, following exercise onset, the RF-d has slower deoxy[Hb+Mb] kinetics with reduced amplitude than superficial muscles. Thirteen participants performed cycle exercise transitions from unloaded to heavy work rates. Within the same muscle (RF-s vs. RF-d) deoxy[Hb+Mb] kinetics (mean response time, MRT) and amplitudes were not different. However, compared with the kinetics of VL-s, deoxy[Hb+Mb] of RF-s and RF-d were slower (MRT: RF-s, 51 ± 23; RF-d, 55 ± 29; VL-s, 18 ± 6 s; P < 0.05). Moreover, the amplitude of total[Hb+Mb] was greater for VL-s than both RF-s and RF-d (P < 0.05). Whereas pulmonary kinetics (i.e., on vs. off) were symmetrical in heavy exercise, there was a marked on-off asymmetry of deoxy[Hb+Mb] for all three sites i.e., MRT-off > MRT-on (P < 0.05). Collectively these data reveal profoundly different O2 transport strategies, with the RF-s and RF-d relying proportionately more on elevated perfusive and the VL-s on diffusive O2 transport. These disparate O2 transport strategies and their temporal profiles across muscles have previously been concealed within the “global” pulmonary response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.14814/phy2.13402

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 36

Metadata

Authors
Koga, S., Okushima, D., Barstow, T. J., Rossiter, H. B., Kondo, N., & Poole, D. C.
Venue
Physiological Reports
Publisher
Wiley
Published
2017-09
Volume
5
Issue
17
Pages
e13402
ISSN
2051-817X (ISSN-L)
OpenAlex
W2755419030
Cited by
36
References
10
FWCI
5.42
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Near-infrared spectroscopy of superficial and deep rectus femoris reveals markedly different exercise response to superficial vastus lateralis. https://app.cochat.ai/papers/10.14814/phy2.13402
The paper
Koga, S., Okushima, D., Barstow, T. J., Rossiter, H. B., Kondo, N., & Poole, D. C. (2017). Near-infrared spectroscopy of superficial and deep rectus femoris reveals markedly different exercise response to superficial vastus lateralis. Physiological Reports. https://doi.org/10.14814/phy2.13402

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.