The DOI matches its Crossref record.
3D-Imaging of cardiac structures using 3D heart models for planning in heart surgery: a preliminary study
Open accessAbstract
The aim of the study was to create an anatomical correct 3D rapid prototyping model (RPT) for patients with complex heart disease and altered geometry of the atria or ventricles to facilitate planning and execution of the surgical procedure. Based on computer tomography (CT) and magnetic resonance imaging (MRI) images, regions of interest were segmented using the Mimics 9.0 software (Materialise, Leuven, Belgium). The segmented regions were the target volume and structures at risk. After generating an STL-file (StereoLithography file) out of the patient's data set, the 3D printer Ztrade mark 510 (4D Concepts, Gross-Gerau, Germany) created a 3D plaster model. The patient individual 3D printed RPT-models were used to plan the resection of a left ventricular aneurysm and right ventricular tumor. The surgeon was able to identify risk structures, assess the ideal resection lines and determine the residual shape after a reconstructive procedure (LV remodelling, infiltrating tumor resection). Using a 3D-print of the LV-aneurysm, reshaping of the left ventricle ensuring sufficient LV volume was easily accomplished. The use of the 3D rapid prototyping model (RPT-model) during resection of ventricular aneurysm and malignant cardiac tumors may facilitate the surgical procedure due to better planning and improved orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Designing Biomaterials for 3D Printing
Guvendiren, M., Molde, J., Soares, R. M. D., & Kohn, J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00121 · Cited by 732
Advantages and disadvantages of 3-dimensional printing in surgery: A systematic review
Martelli, N., Serrano, C., van den Brink, H., Pineau, J., Prognon, P., Borget, I., & El Batti, S. (2016) · Surgery · doi:10.1016/j.surg.2015.12.017 · Cited by 681
Medical 3D Printing for the Radiologist
Mitsouras, D., Liacouras, P., Imanzadeh, A., Giannopoulos, A. A., Cai, T., Kumamaru, K. K., George, E., Wake, N., Caterson, E. J., Pomahac, B., et al. (2015) · RadioGraphics · doi:10.1148/rg.2015140320 · Cited by 619
Cardiac 3D Printing and its Future Directions
Vukicevic, M., Mosadegh, B., Min, J. K., & Little, S. H. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.12.001 · Cited by 535
Applications of 3D printing in cardiovascular diseases
Giannopoulos, A. A., Mitsouras, D., Yoo, S.-J., Liu, P. P., Chatzizisis, Y. S., & Rybicki, F. J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.170 · Cited by 421
Metadata
- Authors
- Jacobs, S., Grunert, R., Mohr, F. W., & Falk, V.
- Venue
- Interactive CardioVascular and Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-01
- Volume
- 7
- Issue
- 1
- Pages
- 6-9
- ISSN
- 1569-9285 (ISSN-L)
- 1569-9293
- OpenAlex
- W2010473200
- Cited by
- 206
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D-Imaging of cardiac structures using 3D heart models for planning in heart surgery: a preliminary study. https://app.cochat.ai/papers/10.1510/icvts.2007.156588
- The paper
- Jacobs, S., Grunert, R., Mohr, F. W., & Falk, V. (2008). 3D-Imaging of cardiac structures using 3D heart models for planning in heart surgery: a preliminary study. Interactive CardioVascular and Thoracic Surgery. https://doi.org/10.1510/icvts.2007.156588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.