CoChat

Incidence and risk factors for pacemaker implantation following aortic valve replacement

Open access
Schurr, Ulrich P., Berli, Jens, Berdajs, Denis, Häusler, Achim, Dzemali, Omer, Emmert, Maximilian, Seifert, Burkhardt, Genoni, Michele · 2010 · Interactive CardioVascular and Thoracic Surgery
Cited by 54

The DOI matches its Crossref record.

Abstract

Our aim was to identify the predictive factors for permanent pacemaker (PM) implantation in patients undergoing isolated aortic valve replacement (AVR). A total of 3534 patients received an AVR between January 1990 and December 2003 in our institution. Permanent PM implantation was performed in 234 (6.6%) patients, over median time of three days (range one to 24 days). This patient population was compared to a random sample of 191 patients undergoing AVR without permanent PM implantation. The overall mean age was 63.5 years (±14.2) and 261 patients (62%) were male. Univariate and multivariate logistic regression analysis of pre- and perioperative data were performed. Overall the 30 days mortality was 4.2% (10/234) in patients with PM and 1% (2/191) in the control group (P=0.046). Patients with PMs were older (P<0.001), had more additional coronary artery bypass grafting (CABG) surgery or mitral valve replacement (MVR) (P<0.001), complete right bundle branch block (RBBB) prior to surgery, and more frequently underwent re-operations compared to patients without PMs (P<0.001). The multivariate logistic regression model with PM implantation as the dependent variable demonstrated that older age was not independently associated with PM implantation. As independent predictors concomitant severe mitral valve insufficiency, CABG, subaortic stenosis (SAS) or re-do operations were identified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1510/icvts.2010.249904

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. Jensen, 1972, Atrioventricular block in aortic insufficiency. Mechanism, ECG features and clinical consequences, Acta Med Scand, 192, 391, 10.1111/j.0954-6820.1972.tb04835.x · doi:10.1111/j.0954-6820.1972.tb04835.x
  2. Thomas, 1982, Prognostic significance of the development of left bundle conduction defects following aortic valve replacement, J Thorac Cardiovasc Surg, 84, 382, 10.1016/S0022-5223(19)39008-7 · doi:10.1016/s0022-5223(19)39008-7
  3. Boughaleb, 1994, Permanent cardiac stimulation after aortic valve replacement: incidence, predictive factors and long-term prognosis, Arch Mal Coeur Vaiss, 87, 925
  4. Glikson, 1997, Indications, effectiveness, and long-term dependency in permanent pacing after cardiac surgery, Am J Cardiol, 80, 1309, 10.1016/S0002-9149(97)00671-1 · DOI
  5. Kim, 2001, Complete atrioventricular block after valvular heart surgery and the timing of pacemaker implantation, Am J Cardiol, 87, 649, 10.1016/S0002-9149(00)01448-X · DOI
  6. Gordon, 1998, Permanent cardiac pacing after a cardiac operation: predicting the use of permanent pacemakers, Ann Thorac Surg, 66, 1698, 10.1016/S0003-4975(98)00889-3 · DOI
  7. Lewis, 1998, The increased need for a permanent pacemaker after reoperative cardiac surgery, Thorac Cardiovasc Surg, 116, 74, 10.1016/S0022-5223(98)70245-4 · DOI
  8. Warshawsky, 1946, Complete heartblock in calcareous aortic stenosis, Ann Intern Med, 27, 1040, 10.7326/0003-4819-27-6-1040 · doi:10.7326/0003-4819-27-6-1040
  9. Bateman, 1985, Fascicular conduction disturbances and ischemic heart disease: adverse prognosis despite coronary revascularization, J Am Coll Cardiol, 5, 632, 10.1016/S0735-1097(85)80388-0 · DOI
  10. Thomas, 1982, Prognostic significance of the development of left bundle conduction defects following aortic valve replacement, J Thorac Cardiovasc Surg, 84, 382, 10.1016/S0022-5223(19)39008-7 · doi:10.1016/s0022-5223(19)39008-7
  11. Chung, 2000, Cardiac surgery: postoperative arrhythmias, Crit Care Med, 28, N136, 10.1097/00003246-200010001-00005 · DOI · Paper page
  12. Limongelli, 2003, Risk factors for pacemaker implantation following aortic valve replacement: a single centre experience, Heart, 89, 901, 10.1136/heart.89.8.901 · DOI · Paper page
  13. Lipton, 1995, Morbidity of permanent pacing following valvular surgery (Abstract), Pace, 13, 554
  14. Brodell, 1991, Cardiac rhythm and conduction disturbances in patients undergoing mitral valve surgery, Cleve Clin J Med, 58, 397, 10.3949/ccjm.58.5.397 · DOI
  15. Keefe, 1985, Atrioventricular conduction abnormalities in patients undergoing isolated aortic or mitral valve replacement, Pacing Clin Electrophysiol, 8, 393, 10.1111/j.1540-8159.1985.tb05777.x · DOI

Cited by

See all 54

Metadata

Authors
Schurr, U. P., Berli, J., Berdajs, D., Häusler, A., Dzemali, O., Emmert, M., Seifert, B., & Genoni, M.
Venue
Interactive CardioVascular and Thoracic Surgery
Published
2010-11-01
Volume
11
Issue
5
Pages
556-560
ISSN
  • 1569-9285 (ISSN-L)
  • 1569-9293
OpenAlex
W1985891415
Cited by
54
References
0
FWCI
1.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence and risk factors for pacemaker implantation following aortic valve replacement. https://app.cochat.ai/papers/10.1510/icvts.2010.249904
The paper
Schurr, U. P., Berli, J., Berdajs, D., Häusler, A., Dzemali, O., Emmert, M., Seifert, B., & Genoni, M. (2010). Incidence and risk factors for pacemaker implantation following aortic valve replacement. Interactive CardioVascular and Thoracic Surgery. https://doi.org/10.1510/icvts.2010.249904

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.