The DOI matches its Crossref record.
Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional Experience
Abstract
Rationale: Technological advances have improved the ability of bronchoscopists to access peripheral pulmonary lesions for tissue sampling. Radial probe endobronchial ultrasound (EBUS) provides real-time feedback to guide biopsies of peripheral lesions, thereby potentially improving diagnostic yield over conventional bronchoscopy. Objectives: We assessed the overall diagnostic yield of peripheral bronchoscopy using radial probe EBUS for peripheral pulmonary lesions, as well as factors that might influence the diagnostic yield, such as radial ultrasound view, lesion size, and ability to locate the peripheral lesion. Methods: We conducted a retrospective review of peripheral bronchoscopy cases in which radial probe EBUS was utilized to diagnose peripheral pulmonary lesions at a tertiary care university hospital. Measurements and Main Results: Our study cohort comprised 496 patients who underwent bronchoscopies between January 2008 and December 2012 for the diagnosis of peripheral pulmonary lesions. Radial probe EBUS was used alone for diagnostic purposes in 467 patients. A diagnosis was made on that basis in 321 (69%) of 467 patients. A diagnosis was obtained for 83 of 144 (58%) of nodules 1–2 cm in diameter, 99 of 137 (72%) of nodules 2.1–3 cm, 54 of 70 (77%) of nodules 3.1–4 cm, 41 of 47 (87%) of nodules 4.1–5 cm, and 35 of 40 (88%) of nodules larger than 5.1 cm. Of all 467 nodules, 446 (96%) were successfully identified using radial probe EBUS. When the radial probe position was within the target lesion, the diagnostic yield was 84% compared with 48% when the probe was positioned adjacent to the lesion. Conclusions: Radial probe EBUS can be used to guide biopsy during peripheral bronchoscopy. This technique provides real-time ultrasound-based confirmation of target lesion localization prior to biopsy. Using radial probe EBUS, the vast majority of peripheral pulmonary nodules can be identified. Radial EBUS probe position relative to the target lesion significantly affects the diagnostic yield.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ali, M. S., Trick, W., Mba, B. I., Mohananey, D., Sethi, J., & Musani, A. I. (2017) · Respirology · doi:10.1111/resp.12980 · Cited by 278
Chronic Pulmonary Aspergillosis—Where Are We? and Where Are We Going?
Hayes, G., & Novak-Frazer, L. (2016) · Journal of Fungi · doi:10.3390/jof2020018 · Cited by 77
Metadata
- Authors
- Chen, A., Chenna, P., Loiselle, A., Massoni, J., Mayse, M., & Misselhorn, D.
- Venue
- Annals of the American Thoracic Society
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-05-01
- Volume
- 11
- Issue
- 4
- Pages
- 578-582
- ISSN
- 2325-6621 (ISSN-L)
- 2329-6933
- OpenAlex
- W2115183273
- Cited by
- 170
- References
- 0
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional Experience. https://app.cochat.ai/papers/10.1513/annalsats.201311-384oc
- The paper
- Chen, A., Chenna, P., Loiselle, A., Massoni, J., Mayse, M., & Misselhorn, D. (2014). Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional Experience. Annals of the American Thoracic Society. https://doi.org/10.1513/annalsats.201311-384oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.