Deposition of Inhaled Particles in the Human Respiratory Tract and Consequences for Regional Targeting in Respiratory Drug Delivery
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Particle behavior in the human respiratory tract is well understood and can be used to (1) estimate particle deposition in all regions of the respiratory tract for any aerosol respired at any pattern, and (2) optimize targeting of all regions of the respiratory tract in respiratory drug delivery. Extrathoracic and alveolar regions can effectively be targeted with mono- and polydisperse aerosols respired steadily. Effective targeting of the bronchial region can only be achieved with bolus inhalations. When particles are suspended in a gas heavier than air, targeting the alveolar region can be enhanced.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a primary pathway of defense in the lower respiratory tract, macrophages phagocytose particles/fibers and promote their mucociliary and lymphatic clearance [90,91,92].”
From Asbestos and Iron (2023) · cites this paper as [91]
Citations
Cites
Deposition of particles in the human respiratory tract in the size range 0.005–15 μm
Heyder, J., Gebhart, J., Rudolf, G., Schiller, C. F., & Stahlhofen, W. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90035-2 · Cited by 1,026 · cited 2×
“... of varying size and density inhaled through the mouth or nose at varying breathing patterns total deposition could be partitioned into deposition in four regions of the respiratory tract (extrathoracic, upper bronchial, lower bronchial, and alveolar region) and a semiempirical deposition model was developed predic…”
MethodSelf-citationLung function. Assessment and application in medicine
(1969) · Tubercle · doi:10.1016/0041-3879(69)90013-0 · Cited by 853
Lung biology in health and disease
Horsmanheimo, M., & Fudenberg, H. H. (1977) · Clinical Immunology and Immunopathology · doi:10.1016/0090-1229(77)90040-x · Cited by 796
(2001) · CRC Press eBooks · doi:10.1201/b14022 · Cited by 153
Inhalation of salt aerosol particles—II. growth and deposition in the human respiratory tract
FERRON, G. A., Kreyling, W. G., & Haider, B. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90213-3 · Cited by 133 · cited 2×
“hydrophilic liquid and a ficticious hydrophobic formulation of terbutaline sulfate simulated with Ferron’s deposition model ( 6 ) for oral resting breathing of an adult white male, are shown in Figures 4 and 5. Deposition of the hydrophilic particles larger than about 0.3 m in median diameter is larger and that of sma…”
MethodInfluentialOptimization of Aerosol Drug Delivery
(2003) · Springer eBooks · doi:10.1007/978-94-017-0267-6 · Cited by 62
Basic Principles of Particle Behavior in the Human Respiratory Tract
Heyder, J., & Svartengren, M. (2001) · Lung biology in health and disease · doi:10.1201/b14022-3 · Cited by 48
Self-citationParticle Deposition in Volumetric Regions of the Human Respiratory Tract
Heyder, J., Blanchard, J. D., & Brain, J. D. (1988) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/32.inhaled_particles_vi.71 · Cited by 13
Self-citationPARTICLE DEPOSITION IN VOLUMETRIC REGIONS OF THE HUMAN RESPIRATORY TRACT
Heyder, J., Blanchard, J. D., & Brain, J. D. (1988) · Elsevier eBooks · doi:10.1016/b978-0-08-034185-9.50013-9 · Cited by 12
Self-citationIntrapulmonary Particle Transport by Diffusiophoresis
Heyder, J., Brand, P., Dua, S. K., Heilmann, P., & Schulz, H. (1994) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/38.inhaled_particles_vii.33 · Cited by 5
Self-citation
Research works printed but not linked: 1
- 1994, Ann Occup Hyg, 38, 33
Cited by
Items 301–400 of 599
Lin, H., Jin, Y. Y., Chen, X., Xie, J. Y., Lu, T., & Xu, Y. (2024) · Powder Technology · doi:10.1016/j.powtec.2024.119853 · Cited by 12
Shani, N., Shani, Z., Shoseyov, O., Mruwat, R., & Shoseyov, D. (2010) · The Journal of Immunology · doi:10.4049/jimmunol.1000640 · Cited by 15
“Although it is assumed that OC particles that reach the deeper regions of the lungs will dissolve, degrade, and undergo macrophagial clearance (33), we propose use of 5–15 mM OC particles to allow for their deposition in the extrathoracic and upper bronchial regions, to further decrease risk of toxicity and enhance ai…”
BackgroundGleeson, P. K., Feldman, S., & Apter, A. J. (2020) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2020.03.003 · Cited by 14
“…(1980)93 Newman (1981)94 Dolovich (1981)95 Newman (1982)96 Lawford (1983)97 Hindle (1993)90 Newman (1995)98 Pavia (1995)99 Farr (1995)92 Heyder (2004)100 Tomlinson (2005)101 Hold breath for 5–10 seconds Newman (1980)93 Newman (1982)96 Hindle (1993)90 Correct second dose preparation…”
Gerde, P., Malmlöf, M., & Selg, E. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105698 · Cited by 12
Aerosol drug delivery in lung transplant recipients
Corcoran, T. E. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425250802685332 · Cited by 13
In vitro evaluation of nonconventional accessory devices for pressurized metered-dose inhalers
Sheth, P., Bertsch, M. D., Knapp, C. L., & Myrdal, P. B. (2014) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2014.04.006 · Cited by 12
Jókay, Á., Farkas, Á., Füri, P., Horváth, A. Z., Tomisa, G., & Balásházy, I. (2016) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2016.03.008 · Cited by 16
Beng, H., Zhang, H., Jayachandra, R., Li, J., Wu, J., & Tan, W. (2018) · Chirality · doi:10.1002/chir.22846 · Cited by 12
Li, J., Wei, X., Gu, L., Qiu, L., Xiang, M., Zhang, H., Xia, L., Pan, W., Yang, Z., Zhou, X., et al. (2022) · Cancer Medicine · doi:10.1002/cam4.4701 · Cited by 11
“Mixed lung cancer 25 (4) 5 (5) 5 (8) 6 (5) 9 (3)”
Particle Deposition in Large-Scale Human Tracheobronchial Airways Predicted by Single-Path Modelling
Ou, C., Hang, J., Hua, J., Li, Y., Deng, Q., Zhao, B., & Ling, H. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20054583 · Cited by 13
“Previous studies have focused on either the deposition mechanisms in simple bifurcation airway models [48–50] or the deposition patterns in complicated airway models but without precise descriptions for the mechanisms [51,52], which cannot shed light on the deposition mechanisms in depth.”
BackgroundAssociation of Bovine Arch Anatomy With Incident Stroke After Transcatheter Aortic Valve Replacement
Russo, G. L., Alarouri, H. S., Al-Abcha, A. K., Vogl, B. J., Mahayni, A. A., Sularz, A., Hatoum, H., Collins, J. D., Crestanello, J. A., & Alkhouli, M. A. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.032963 · Cited by 12
“26 Although these findings may theoretically contribute to explaining our results, caution is needed because in vivo blood flow characteristics are markedly different compared with those present in simulation and in vitro models.”
ResultInfluence of Rainfall on Size-Resolved Bioaerosols Around a Livestock Farm
Kwak, N., Tsameret, S., Gaire, T. N., Mendoza, K. M., Cortus, E. L., Cardona, C. J., Noyes, N. R., & Li, J. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.176184 · Cited by 12
Electronic cigarettes—A review of the physiological health effects
Zucchet, A., & Schmaltz, G. (2017) · FACETS · doi:10.1139/facets-2017-0014 · Cited by 15
Dry aerosol particle deposition on indoor surfaces: Review of direct measurement techniques
Costa, D., Malet, J., & Géhin, É. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.2013431 · Cited by 11
“From another point of view, by knowing more about where and how particles deposit in airways, respiratory drug delivery and efficiency could be better controlled (Duan et al. 2020; Darquenne 2012; Heyder 2004).”
BackgroundLi, P., Guo, W., Fan, J., Su, C., Zhao, X., & Xu, X. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2022.106077 · Cited by 11
Bárbara Sandoval, D., Tatiana. Reyes, R., & Manuel Oyarzún, G. (2019) · Revista chilena de enfermedades respiratorias · doi:10.4067/s0717-73482019000100049 · Cited by 24
Hospital, health, and community burden after oil refinery fires, Richmond, California 2007 and 2012
Remy, L. L., Clay, T., Byers, V. S., & Rosenfeld, P. (2019) · Environmental Health · doi:10.1186/s12940-019-0484-4 · Cited by 11
Popov, T. A., Emberlin, J. C., Josling, P., & Seifalian, A. M. (2020) · Medical Devices Evidence and Research · doi:10.2147/mder.s236104 · Cited by 11
Aerosol deposition in 3D models of the upper airways and trachea of rhesus macaques
Kesavan, J. S., Alstadt, V. J., & Laube, B. L. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1757031 · Cited by 11
“In humans, inhaled particles >5mm have a high probability of depositing in the upper airways during nasal breathing (Heyder 2004).”
BackgroundFischer, T., Tschernig, T., Drews, F., Brix, K., Meier, C., Simon, M. C., Kautenburger, R., & Schneider, M. (2020) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.11.024 · Cited by 11
Odziomek, M., Sosnowski, T. R., & Gradoń, L. (2014) · Transport in Porous Media · doi:10.1007/s11242-014-0409-1 · Cited by 11
“…m3/h, and outflow temperature: 55 ◦C) allowed to maximize powder yield and the content of particles smaller than 5 µm (fine particle fraction—FPF), i.e., particles expected to penetrate and deposit in the tracheobronchial tree with the highest efficiency (Heyder 2004; Koushik and Kompella 2004).”
BackgroundAn advanced stochastic model for mucociliary particle clearance in cystic fibrosis lungs.
Sturm, R. (2012) · PubMed · doi:10.3978/j.issn.2072-1439.2011.09.09 · Cited by 14
Pichelin, M., Caillibotte, G., Katz, I. M., & Martonen, T. B. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.605816 · Cited by 12
“This optimization of deposition can be realized by controlling aerosol properties (e.g., diameters or material densities) and/or regulating breathing patterns (Heyder 2004).”
BackgroundInspiromatic‐safety and efficacy study of a new generation dry powder inhaler in asthmatic children
Steuer, G., Prais, D., Mussaffi, H., Mei‐Zahav, M., Bar‐On, O., Levine, H., Gendler, Y., Blau, H., & Stafler, P. (2018) · Pediatric Pulmonology · doi:10.1002/ppul.24077 · Cited by 11
“Lung deposition may be optimized by applying inspiratory flows that are sufficiently high to achieve drug release and de-agglomeration of the API, but not too high, as to avoid oropharyngeal deposition.(20,21) The Inspiromatic may respond to this need.”
BackgroundCharacterization of Nanomaterials for Toxicological Evaluation
Powers, K. W., Palazuelos, M., Brown, S. C., & Roberts, S. M. (2009) · doi:10.1002/9780470747803.ch1 · Cited by 11
Boydston, J. A., Biryukov, J., Yeager, J. J., Zimmerman, H. A., Williams, G., Green, B., Reese, A. L., Beck, K., Bohannon, J. K., Miller, D., et al. (2023) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2022.0072 · Cited by 9
A mobile air-liquid interface exposure system optimized for outdoor toxicity testing of aerosols
Juárez-Facio, A. T., Introna, M., Gustavsson, S. Å., Attergren, M., Lindwall, M., Olofsson, U., Steimer, S. S., & Elihn, K. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2426487 · Cited by 12
“Deposition probability of airborne particles at different levels of the respiratory tract is determined mainly by their size (Heyder 2004).”
Kinsale, L. K., Kazemi, M. A., Elliott, J. A. W., & Nobes, D. S. (2019) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2019.109894 · Cited by 10
Controls for University Fabrication Laboratories—Best Practices for Health and Safety
Zontek, T. L., Scotto, N., & Hollenbeck, S. M. (2020) · ACS Chemical Health & Safety · doi:10.1021/acs.chas.0c00093 · Cited by 10
Wiegandt, F. C., Biegger, D., Fast, J. F., Matusiak, G., Mazela, J. L., Ortmaier, T., Doll, T., Dietzel, A. H., Bohnhorst, B., & Pohlmann, G. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050721 · Cited by 13
Atmospheric plastics- a potential airborne fomite with an emerging climate signature
VishnuRadhan, R., Thresyamma, D. D., Eldho, T. I., & Bhagat, J. (2021) · The Journal of Climate Change and Health · doi:10.1016/j.joclim.2021.100037 · Cited by 12
Jagdale, P., Sepp, A., & Shah, D. K. (2022) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-022-09824-w · Cited by 11
“space.[7] The absorbed protein initially encounters the epithelial lining fluid (ELF), which is a thin”
BackgroundA Novel Optical Instrument for Measuring Mass Concentration and Particle Size in Real Time
Zhang, J., Zhang, Z., Hou, L., & Zhou, W. (2023) · Sensors · doi:10.3390/s23073616 · Cited by 10
Zinc chloride-induced TRPA1 activation does not contribute to toxicity in vitro
Steinritz, D., Zehfuß, F., Stenger, B., Schmidt, A., Popp, T., Kehe, K., Mückter, H., Thiermann, H., & Gudermann, T. W. (2017) · Toxicology Letters · doi:10.1016/j.toxlet.2017.09.008 · Cited by 10
Speranza, A., Caggiano, R., Pavese, G., & Summa, V. (2018) · Condensed Matter · doi:10.3390/condmat3020016 · Cited by 10
“PM particles when inhaled can be deposited within the respiratory system and can act as a universal carrier of a wide variety of chemical substances potentially toxic [4,5].”
BackgroundWatanabe, J., & Watanabe, M. (2019) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2019.03.004 · Cited by 10
Quantification and Comparison of Risks Associated with Wastewater Use in Spray Irrigation
Mori, J. J., Uprety, S., Mao, Y., Koloutsou‐Vakakis, S., Nguyen, T. H., & Smith, R. L. (2020) · Risk Analysis · doi:10.1111/risa.13607 · Cited by 10
“These size cutoffs are typically 10 μm (Heyder, 2004) and 100 μm (Van Leuken et al.”
BackgroundMethodThe environment shapes swine lung bacterial communities
McCumber, A. W., Kim, Y. J., Isikhuemhen, O. S., Tighe, R. M., & Gunsch, C. K. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.143623 · Cited by 9
Caruso, G., Fresta, C. G., Costantino, A., Lazzarino, G., Amorini, A. M., Lazzarino, G., Tavazzi, B., Lunte, S. M., Dhar, P., Gulisano, M., et al. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22052694 · Cited by 12
“In the aforementioned study, A549 cells (alveolar basal epithelial phenotype) were selected because the lung represents a primary site of nanoparticle retention after inspiration [17] and are also a preference model to study toxicity linked to ROS overproduction [24–26],”
BackgroundDelivery and actuation of aerosolized microbots
Zimmermann, C. J., Schraeder, T., Reynolds, B., DeBoer, E. M., Neeves, K. B., & Marr, D. W. M. (2022) · Nano Select · doi:10.1002/nano.202100353 · Cited by 10
Respiration triggered magnetic drug targeting in the lungs
Dahmani, C., Götz, S., Weyh, T., Renner, R., Rosenecker, M., & Rudolph, C. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332476 · Cited by 10
“In actual research works [ 9 ], [10], it has been experimentally validated, that the time accurate injection of particles has a big impact on the reachable depth in the bronchial tree.”
BackgroundKopsch, T., Murnane, D., & Symons, D. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.07.002 · Cited by 10
“Good lung deposition requires particle sizes between 0.1 mm and 10 mm (Heyder, 2004).”
BackgroundInfluentialSokolova, A. B., Suslova, K. G., & Miller, S. C. (2016) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncw218 · Cited by 9
Chakraborty, A., Hertel, A. K., Ditmars, H., & Dhar, P. (2020) · Molecules · doi:10.3390/molecules25030714 · Cited by 9
“The small size allows the particles to reach the depths of the alveoli [12].”
BackgroundScaramboni, C., Campos, M. L. A. M., Dorta, D. J., de Oliveira, D. P., de Medeiros, S. R. B., Galvão, M. F. D. O., & Dreij, K. (2023) · Toxicology in Vitro · doi:10.1016/j.tiv.2023.105628 · Cited by 9
Huijghebaert, S., Parviz, S., Rabago, D., Baxter, A. L., Chatterjee, U. S., Khan, F. R., Fabbris, C., Poulas, K. A., & Hsu, S. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1161881 · Cited by 14
Bayesian Development of a Dose‐Response Model for Aspergillus fumigatus and Invasive Aspergillosis
Leleu, C., Ménotti, J., Meneceur, P., Choukri, F., Sulahian, A., GARIN, Y. J. F., Denis, J., & Derouin, F. (2013) · Risk Analysis · doi:10.1111/risa.12007 · Cited by 9
“reached the lung tissues.(40,41) In the other study an infective dose of 2.”
BackgroundAn asymptotic model of particle deposition at an airway bifurcation
Zierenberg, J. R., Halpern, D., Filoche, M., Sapoval, B., & Grotberg, J. B. (2012) · Mathematical Medicine and Biology A Journal of the IMA · doi:10.1093/imammb/dqs002 · Cited by 9
“According to Heyder (2004), total deposition is defined to be the probability that a particle is deposited in one of the airways.”
BackgroundInfluentialEvaluation of adsorption of DNA/PEI polyplexes to tubing materials
Keil, T. W. M., Deiringer, N., Frieß, W., & Merkel, O. M. (2022) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2022.08.014 · Cited by 9
Green, N., Haddrell, A. E., Gregson, F. K. A., Lewis, D., Church, T. K., & Reid, J. P. (2024) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.4c02158 · Cited by 8
Paddy, E. N., Sohail, M., & Afolabi, O. O. D. (2025) · Journal of Hospital Infection · doi:10.1016/j.jhin.2025.02.012 · Cited by 9
Vanderstocken, G., Woolf, N. L., Trigiante, G., Jackson, J. R., & McGoldrick, R. (2022) · Biomedicines · doi:10.3390/biomedicines10061440 · Cited by 10
“Moreover, physical characteristics of the administered form of the drug, such as viscosity, conductivity, osmolality, pH and particle size, need to be considered too as they affect in which parts of the airways the drug will be deposited and can be absorbed and tolerated [82,92,93].”
BackgroundMoon, J., Kim, S. H., Kim, Y., Lee, H. J., Rhee, C. K., Won, S., Lee, C. Y., Park, J. H., Park, Y. B., & Yoo, K. H. (2024) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2024.102298 · Cited by 11
González-Torralba, F., Baloira, A., Abad, A., Fuster, A., Rivero, J. L. G., García-Sidro, P., Martín, E. M., Palop, M., Soler, N., & Velasco, J. L. (2022) · International Journal of COPD · doi:10.2147/copd.s360938 · Cited by 8
“an inhaler device are: a high lung deposition, defined as the average probability of an inhaled particle being deposited in the lung, and the correct delivery of the drug despite the presence of a low inspiratory flow.(12) A low inspiratory flow is associated with the presence of pulmonary hyperinflation, which is def…”
BackgroundRisk of Legionellosis in residential areas around farms irrigating with municipal wastewater
Mori, J. J., & Smith, R. L. (2022) · Risk Analysis · doi:10.1111/risa.13997 · Cited by 8
“…0.6, max = 1.5 US EPA (2011) Percent wastewater P % Uniform Min = 0.05, max = 0.2 Dungan (2014) Alveolar retention rate RR % Uniform Min = 0, max = 0.5 Heyder (2004) L. pneumophila source concentration LP cfu/L Uniform Min = 0, Max = 125000 Johnson et al. (2018) Risk characterization Exponential…”
BackgroundInfluentialYan, G., Zhang, J., Zhang, P., Cao, Z., Zhu, G., Liu, Z., & Wang, Y. (2020) · Applied Sciences · doi:10.3390/app10103498 · Cited by 8
Atmen: Luftschadstoffe und Gesundheit – Teil II
Schulz, H., Karrasch, S., Bölke, G., Cyrys, J., Hornberg, C., Pickford, R., Schneider, A., Witt, C. C., & Hoffmann, B. H. (2019) · Pneumologie · doi:10.1055/a-0895-6494 · Cited by 14
Prediction of particle deposition in the lungs based on simple modeling of alveolar mixing
Georgakakou, S., Gourgoulianis, K. I., Daniil, Z. D., & Bontozoglou, V. (2016) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2015.12.009 · Cited by 11
Boyce, C. P., Sax, S. N., & Cohen, J. M. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1309046 · Cited by 8
Ryan, R. C., Leslie, M. N., He, P., Young, P. M., Hoyos, C. M., Ong, H. X., & Traini, D. (2025) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2025.115575 · Cited by 11
Self‐infection with speech aerosol may contribute to COVID‐19 severity
Kushalnagar, P., Chow, C. C., & Bax, A. (2021) · Journal of Internal Medicine · doi:10.1111/joim.13370 · Cited by 7
Payne, S. D., Johnson, T. J., & Symonds, J. P. R. (2023) · Aerosol and Air Quality Research · doi:10.4209/aaqr.230008 · Cited by 7
“where B is the particle mobility, m is the particle mass, ρ0 is a density of 1000 kg m-3, μ is the viscosity of the gas, da is the aerodynamic equivalent diameter of the particle and Cc is the Cunningham slip correction factor. The aerodynamic equivalent diameter is defined as the diameter of a spherical particle with…”
InfluentialDetection of fungi in the airways of horses according to the sample site: a methodological study
Lemonnier, L., Couroucé, A., Cessans, M., Petit, L., Cardwell, J. M., Barbazanges, P., Toquet, M., & Richard, E. A. (2023) · Veterinary Research Communications · doi:10.1007/s11259-023-10213-y · Cited by 7
“Indeed, it has been described that in humans, particles smaller than 10 μm in diameter have the potential of being biologically active (Heyder 2004).”
Wu, K., Tao, J., Wu, Q., Su, H., Huang, C., Xia, Q., Zhu, C., Wei, J., Yang, M., Yan, J., et al. (2024) · Environmental Pollution · doi:10.1016/j.envpol.2024.123677 · Cited by 7
Yang, S., Tu, C., Dai, M., Ge, X., Xu, R., Gao, X., & Bao, F. (2021) · Applied Sciences · doi:10.3390/app11157113 · Cited by 7
“Since many processes involving particle settling occur in non-Newtonian fluids [14,15], such as hydraulic fracture for oil exploration [16], sedimentation velocity analytical ultracentrifugation in biopharmaceuticals [17], the behavior of particles in the human respiratory tract [18] and the transport of the particles…”
BackgroundBarudgar, A., Singh, J., & Tyagi, B. (2022) · Thalassas An International Journal of Marine Sciences · doi:10.1007/s41208-022-00442-4 · Cited by 8
“The PM enters the human respiratory system via the nose with the breath, passing through nasal mucus, a slippery liquid that catches particulate passing through it (Heyder 2004).”
BackgroundActively Breathing Mechanical Lung Simulator Development and Preliminary Measurements
Paštěka, R., & Forjan, M. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_188 · Cited by 9
An immune cell spray (ICS) formulation allows for the delivery of functional monocyte/macrophages
Beneke, V., Küster, F., Neehus, A., Hesse, C., López-Rodríguez, E., Haake, K., Hashtchin, A. R., Schott, J. W., Walter, D., Braun, A. C., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34524-2 · Cited by 8
Tan, J. Y., Bonatesta, F., Ng, H. K., & Gan, S. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.9b03945 · Cited by 7
Sonnenberg, A. H., Taylor, E., Mondoñedo, J. R., Jawde, S. B., Amin, S. D., Song, J., Grinstaff, M. W., & Suki, B. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02623-9 · Cited by 7
Roberts, R., Gettz, K. P., Stebounova, L. V., Shatkin, J. A., Peters, T. M., & Foster, E. J. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1540876 · Cited by 8
Toxicity of airborne dust as an indicator of moisture problems in school buildings
Tirkkonen, J., Täubel, M., Leppänen, H., Peltonen, M., Lindsley, W. G., Chen, B. T., Hyvärinen, A., Hirvonen, M., & Huttunen, K. (2017) · Inhalation Toxicology · doi:10.1080/08958378.2017.1296511 · Cited by 11
“Collecting size segregated airborne PM is justified considering that the particles smaller than 10 lm in their diameter can reach a particular region of the respiratory system and potentially deposit there (Heyder, 2004).”
BackgroundMellat, M., Momtazi‐Borojeni, A. A., Sahebkar, A., & Ghanei, M. (2016) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2016.12.002 · Cited by 6
Development of dry powder inhaler formulations for drug delivery systems
Akdağ, Y. (2019) · Sanat-tasarım dergisi/Sanat - tasarım dergisi · doi:10.35333/jrp.2019.62 · Cited by 8
“Particle size distribution, density, shape, charge, hygroscopicity, and surface properties are other critical factors that define the area of deposition in the respiratory tract [24, 25].”
BackgroundNano-structured microparticles for inhalation
Koenneke, A., Pourasghar, M., & Schneider, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817776-1.00006-7 · Cited by 9
How does the dielectrophoresis affect the soot dendrite growth on resistive sensors?
Reynaud, A., Leblanc, M., Ranarivelo, V. B., Zinola, S., Breuil, P., & Viricelle, J.-P. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112729 · Cited by 6
Ex vivo pulmonary assay applied for screening of toxicity potential of chemicals
Hayasaki, T. G., dos Santos, T. R. M., da Silva, A. C. G., & Valadares, M. C. (2022) · Food and Chemical Toxicology · doi:10.1016/j.fct.2022.112820 · Cited by 6
Factors Affecting Drug Exposure after Inhalation
Nováková, A., Šíma, M., & Slanař, O. (2022) · Prague Medical Report · doi:10.14712/23362936.2022.13 · Cited by 6
Choi, Y. J., Han, H., Lee, J., Lee, J., Kim, C. Y., Byun, M. K., Cho, J. H., & Park, H. J. (2023) · Respiratory Research · doi:10.1186/s12931-023-02392-8 · Cited by 6
“PM10 is a major air pollutant, and exposure to chronic PM10 can induce, facilitate, and aggravate airway inflammation and fibrosis [31, 32].”
An Overview on the Safety of Tubular Clay Minerals
Jaurand, M. (2016) · Developments in clay science · doi:10.1016/b978-0-08-100293-3.00020-0 · Cited by 6
Gravel-Tatta, L., DeWolf, C., & Badia, A. (2021) · Langmuir · doi:10.1021/acs.langmuir.1c01906 · Cited by 6
Customized Vibrating-Membrane Nozzles for Enhanced Fluid Atomization
Beck‐Broichsitter, M., Schmehl, T., & Seeger, W. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1008623 · Cited by 6
“, bronchioles and alveoli) mass median aerodynamic diameters (da) of 1–5 mm are preferable (Heyder 2004; Hofmann 2011).”
BackgroundInfluentialFormation and measurement of process induced disorder during the manufacture of inhalation medicines
Royall, P. G., Woodhead, B. J., Tang, S., Martin, G., Stockton, B. M., & Murnane, D. (2011) · Journal of Drug Delivery Science and Technology · doi:10.1016/s1773-2247(11)50048-6 · Cited by 6
Dhanani, J., Tang, P., Wallis, S. C., Parker, S. L., Pandey, P. M., Fraser, J. F., Cohen, J., Barnett, A. G., Roberts, J. A., & Chan, H. (2018) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2018.04.006 · Cited by 6
Quon, H., Ram, D., Sylvestre, É., & Hamilton, K. A. (2025) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.5c00488 · Cited by 5
do Nascimento, R. D. K. S., Carvalho, J. S., Miranda, R. R., Lima, M. A., Rocha, F. V., Zucolotto, V., Lynch, I., & Urban, R. C. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.139484 · Cited by 6
Pharmacological Consequences of Inhaled Drug Delivery to Small Airways in the Treatment of Asthma
Bodzenta‐Łukaszyk, A., & Kokot, M. (2014) · Advances in Therapy · doi:10.1007/s12325-014-0143-7 · Cited by 5
“Numerous experimental studies have revealed that most aerosolized particles [5 lm in diameter are deposited in the oropharynx [12, 13].”
Moazami, T. N., Hilt, B., Svendsen, K., Buhagen, M., & Jørgensen, R. B. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.146309 · Cited by 5
Andersen, M. E. (2022) · Toxicology Letters · doi:10.1016/j.toxlet.2021.12.020 · Cited by 5
Barriers for orally inhaled therapeutic antibodies
Sécher, T., & Heuzé‐Vourc'h, N. (2023) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2023.2249821 · Cited by 6
“In the conductive airways, where the air velocity is slower, gravitational sedimentation is the main deposition mechanism for particles with a MMAD ~ 0.5–5 µm [20].”
BackgroundInfluentialLe choix du dispositif d’inhalation (hors nébulisation) : un acte médical
Devillier, P., Salvator, H., & Roche, N. (2014) · Revue des Maladies Respiratoires · doi:10.1016/j.rmr.2014.10.729 · Cited by 5
Tsai, C. S., Mao, R. W., Zhu, Y. F., Chien, E., Maduzia, J., Tsai, S. C., Brenner, M., Mahon, S. B., Mukai, D. S., Lee, J., et al. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0409 · Cited by 5
“Particles between 5 and 1μm (the “respirable” fraction) enter the respiratory system [1, 2] and deposit in progressively smaller airways [2].”
BackgroundSperanza, A., Caggiano, R., & Summa, V. (2019) · Environmental Monitoring and Assessment · doi:10.1007/s10661-019-7828-y · Cited by 5
“…Gerasopoulos et al. (2007), Giugliano et al. (2005), Godec et al. (2012), Halek et al (2010), Haller et al. (1999), Hassanvand et al. (2014), Hieu & Lee (2010), Keywood et al. (1999), Klejnowski et al. (2012), Laakso et al. (2003), Li et al. (2015), Mandija et al. (2011), Pérez et al.…”
Non-absorptive clearance from airways
Donnelley, M., Gardner, M., Morgan, K. S., & Parsons, D. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-814974-4.00002-x · Cited by 9
Study on Deposition Characteristics of Microparticles in Terminal Pulmonary Acini by IB–LBM
Xu, D.-C., Luo, Y.-X., & Xu, Y. (2021) · Micromachines · doi:10.3390/mi12080957 · Cited by 5
“The deposition of microparticles smaller than 20 μm has been generally studied [25], and the effect of Brownian movement to the microparticles, whose diameters are larger than 1 μm, are negligible.”
BackgroundLi, W., Skinner, R., Megna, K., Chen, J., Perera, S., Murimboh, J., Waller, E. J., Erhardt, L., & Cornett, R. J. (2008) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-007-7306-4 · Cited by 5
Pourquoi et comment mesurer et optimiser le dépôt pulmonaire des traitements inhalés ?
Devillier, P., Naline, E., & Dubus, J. ‐. (2009) · Revue des Maladies Respiratoires · doi:10.1016/s0761-8425(09)73539-9 · Cited by 5
Pharmaceutical Aerosols and Pulmonary Drug Delivery
Murnane, D., Hutter, V., & Harang, M. (2013) · Wiley eBooks · doi:10.1002/9781118682555.ch10 · Cited by 7
In Vivo Toxicity Studies of Metal and Metal Oxide Nanoparticles
Adamcakova‐Dodd, A., Thorne, P. S., & Grassian, V. H. (2009) · Wiley eBooks · doi:10.1002/9780470744307.gat244 · Cited by 6
“The deposition of NP within the respiratory system happens primarly by diffusion (Heyder, 2004; Kreyling, Semmler and Moller, 2004) and secondarily by thermodiffusion in the first few airways of the lungs during exhalation (Asgharian and Price, 2007).”
BackgroundSimulating near‐field enhancement in transmission of airborne viruses with a quadrature‐based model
Fierce, L. M., Robey, A. J., & Hamilton, C. (2021) · Indoor Air · doi:10.1111/ina.12900 · Cited by 20
Metadata
- Authors
- Heyder, J.
- Affiliations
- Helmholtz Munich (DE)
- Corresponding author
- Heyder, Joachim
- Venue
- Proceedings of the American Thoracic Society
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-01
- Volume
- 1
- Issue
- 4
- Pages
- 315-320
- ISSN
- 1546-3222 (ISSN-L)
- 1943-5665
- OpenAlex
- W2046370810
- Cited by
- 601
- References
- 10
- Citations by year
- 2026: 22 · 2025: 30 · 2024: 34 · 2023: 38 · 2022: 42 · 2021: 58 · 2020: 51 · 2019: 52 · 2018: 35 · 2017: 36 · 2016: 31 · 2015: 23 · 2014: 30 · 2013: 25 · 2012: 24
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the American Thoracic Society (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Particle Dynamics in Fluid Flows
- Keywords
- inhaled particle deposition, respiratory tract, pulmonary drug delivery, aerosol deposition, bronchial deposition, alveolar deposition, polydisperse aerosols, aerosol density
- MeSH terms
- Administration, Inhalation, Humans, Particle Size, Respiratory System, Respiratory Physiological Phenomena, Sensitivity and Specificity, Respiratory Mechanics, Drug Delivery Systems, Respiratory System Agents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.