CoChat

Criteria of Viability of Isolated Liver Cells

Baur, Hartmut, Kasperek, Sylvia, Pfaff, Erich · 1975 · Hoppe-Seyler´s Zeitschrift für physiologische Chemie
Cited by 405

The DOI matches its Crossref record.

Abstract

36.4 +/Various cellular parameters were measured with regard to their usefulness as criteria of viability of isolated cells. Stainability by trypan blue and release of lactate dehydrogenase indicate only severe irreversible damage of cells. Neither endogenous respiration nor even the ATP/ADP ratio is a sensitive criterion of viability. On aging of cells, the ATP/ADP ratio remains high, even though the membrane potential, the intracellular K concentration and the content of adenine nucleotides decrease considerably. A sensitive, easily performed test is the stimulation of cellular respiration by 1mM succinate. Only a damaged plasma membrane allows succinate permeation of a rate sufficient to stimulate respiration. The membrane potential and the intracellular Na and K concentrations are the most sensitive criteria of viability, since they indicate the earliest changes on aging. (For freshly isolated cells, we found a membrane potential of 36.4 "/- 3.4 mv [n = 5], an intracellular K concentration of 109.0 +/- 9.1 mM, and an intracellular Na concentration of 47.0 +/- 13.4mM.) The incorporation of [14C]uridine also sensitively reflects cellular damage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/bchm2.1975.356.s1.827

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Baur, H., Kasperek, S., & Pfaff, E.
Venue
Hoppe-Seyler´s Zeitschrift für physiologische Chemie
Published
1975-01
Volume
356
Issue
s1
Pages
827-838
ISSN
0018-4888 (ISSN-L)
OpenAlex
W2314285093
Cited by
405
References
0
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.