CoChat

Interference of the new oral anticoagulant dabigatran with frequently used coagulation tests

Halbmayer, Walter-Michael, Weigel, Guenter, Quehenberger, Peter, Tomasits, Josef, Haushofer, Alexander C., Aspoeck, Gerold, Loacker, Lorin, Schnapka-Koepf, Mirjam, Goebel, Georg, Griesmacher, Andrea · 2012 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 63

The DOI matches its Crossref record.

Abstract

Dabigatran etexilate is a new oral anticoagulant for the therapy and prophylaxis of venous thromboembolism and stroke prevention in patients with atrial fibrillation. To investigate the extent of interactions of this new anticoagulant with frequently used coagulation assays, we completed a multicenter in vitro trial with Conformité Européenne(CE)-labeled dabigatran-spiked plasma samples. Lyophilized plasma samples with dabigatran concentrations ranging from 0.00 to 0.48 μg/mL were sent to the coagulation laboratories of six major Austrian hospitals for evaluation. Coagulation assays were performed under routine conditions using standard reagents and analyzer. Dabigatran led to a dose-dependent prolongation of the clotting times in coagulometric tests and influenced the majority of the parameters measured. Statistically significant interference could be observed with the prothrombin time (PT), activated partial thromboplastin time (aPTT) and PT/aPTT-based assays (extrinsic/intrinsic factors, APC-resistance test) as well as lupus anticoagulant testing. Even non-clotting tests, such as the colorimetric factor XIII activity assay and to a minor extent the amidolytic antithrombin activity assay (via factor IIa) were affected. This multicenter trial confirms and also adds to existing data, demonstrating that laboratories should expect to observe strong interferences of coagulation tests with increasing concentrations of dabigatran. This finding might become particularly important in the elderly and in patients with renal impairment as well as patients whose blood is drawn at peak levels of dabigatran.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2011-0888

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 63

Metadata

Authors
Halbmayer, W.-M., Weigel, G., Quehenberger, P., Tomasits, J., Haushofer, A. C., Aspoeck, G., Loacker, L., Schnapka-Koepf, M., Goebel, G., & Griesmacher, A.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2012-09-01
Volume
50
Issue
9
Pages
1601-5
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2054769245
Cited by
63
References
0
FWCI
5.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interference of the new oral anticoagulant dabigatran with frequently used coagulation tests. https://app.cochat.ai/papers/10.1515/cclm-2011-0888
The paper
Halbmayer, W.-M., Weigel, G., Quehenberger, P., Tomasits, J., Haushofer, A. C., Aspoeck, G., Loacker, L., Schnapka-Koepf, M., Goebel, G., & Griesmacher, A. (2012). Interference of the new oral anticoagulant dabigatran with frequently used coagulation tests. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2011-0888

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.