Interference of the new oral anticoagulant dabigatran with frequently used coagulation tests
The DOI matches its Crossref record.
Abstract
Dabigatran etexilate is a new oral anticoagulant for the therapy and prophylaxis of venous thromboembolism and stroke prevention in patients with atrial fibrillation. To investigate the extent of interactions of this new anticoagulant with frequently used coagulation assays, we completed a multicenter in vitro trial with Conformité Européenne(CE)-labeled dabigatran-spiked plasma samples. Lyophilized plasma samples with dabigatran concentrations ranging from 0.00 to 0.48 μg/mL were sent to the coagulation laboratories of six major Austrian hospitals for evaluation. Coagulation assays were performed under routine conditions using standard reagents and analyzer. Dabigatran led to a dose-dependent prolongation of the clotting times in coagulometric tests and influenced the majority of the parameters measured. Statistically significant interference could be observed with the prothrombin time (PT), activated partial thromboplastin time (aPTT) and PT/aPTT-based assays (extrinsic/intrinsic factors, APC-resistance test) as well as lupus anticoagulant testing. Even non-clotting tests, such as the colorimetric factor XIII activity assay and to a minor extent the amidolytic antithrombin activity assay (via factor IIa) were affected. This multicenter trial confirms and also adds to existing data, demonstrating that laboratories should expect to observe strong interferences of coagulation tests with increasing concentrations of dabigatran. This finding might become particularly important in the elderly and in patients with renal impairment as well as patients whose blood is drawn at peak levels of dabigatran.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laboratory Measurement of the Anticoagulant Activity of the Non–Vitamin K Oral Anticoagulants
Cuker, A., Siegal, D. M., Crowther, M. A., & Garcia, D. A. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.05.065 · Cited by 449
Gosselin, R., Adcock, D., Bates, S., Douxfils, J., Favaloro, E., Gouin-Thibault, I., Guillermo, C., Kawai, Y., Lindhoff-Last, E., & Kitchen, S. (2018) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1627480 · Cited by 392
Laboratory Assessment of the Anticoagulant Activity of Direct Oral Anticoagulants
Samuelson, B. T., Cuker, A., Siegal, D. M., Crowther, M., & Garcia, D. A. (2017) · Chest · doi:10.1016/j.chest.2016.08.1462 · Cited by 345
Kitchen, S., Gray, E., Mackie, I., Baglin, T., Makris, M., & the BCSH committee (2014) · British Journal of Haematology · doi:10.1111/bjh.12975 · Cited by 167
Recent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 149
“17,74 Although the multiple acquired factor de fi ciency of VKA anticoagulation can often be corrected in a mixing test and reveal a LA, there is no such correction with DTIs or factor Xa (FXa) inhibitors as there is usually no underlying factor de fi ciency.”
BackgroundMartinuzzo, M. E., Barrera, L. H., D 'Adamo, M. A., Otaso, J. C., Gimenez, M. I., & Oyhamburu, J. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12138 · Cited by 91
“extensive paper published recently [5, 6].”
Effects of Direct Oral Anticoagulants on Lupus Anticoagulant Assays in a Real-Life Setting
Antovic, A., Norberg, E.-M., Berndtsson, M., Rasmuson, A., Malmström, R. E., Skeppholm, M., & Antovic, J. (2017) · Thrombosis and Haemostasis · doi:10.1160/th17-03-0204 · Cited by 46
Dilute Russell's viper venom time reagents in lupus anticoagulant testing: a well‐considered choice
Depreter, B., & Devreese, K. M. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0245 · Cited by 34
Hillarp, A., Strandberg, K., Gustafsson, K. M., & Lindahl, T. L. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14829 · Cited by 23
Metadata
- Authors
- Halbmayer, W.-M., Weigel, G., Quehenberger, P., Tomasits, J., Haushofer, A. C., Aspoeck, G., Loacker, L., Schnapka-Koepf, M., Goebel, G., & Griesmacher, A.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2012-09-01
- Volume
- 50
- Issue
- 9
- Pages
- 1601-5
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2054769245
- Cited by
- 63
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.