Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Low serum adropin is associated with coronary atherosclerosis in type 2 diabetic and non-diabetic patients

Wu, Lingzhen, Fang, Jun, Chen, Lianglong, Zhao, Ziwen, Luo, Yukun, Lin, Chaogui, Fan, Lin · 2014 · Clinical Chemistry and Laboratory Medicine

Abstract

BACKGROUND: Diabetes increases the risk and severity of atherosclerosis. Adropin, a metabolic homeostasis-related protein, has been implicated in the maintenance of metabolic homeostasis. We examined the relationship between serum adropin level and angiographic severity of coronary atherosclerosis in diabetic and non-diabetic patients. METHODS: A total of 392 patients with suspected coronary artery disease, who underwent coronary angiography, were assigned into the type 2 diabetic and non-diabetic groups and also classified into four groups according to the quartiles of adropin level. Venous serum samples were collected for adropin measurement by enzyme-linked immunosorbent assay and for biochemistry assay. The angiographic severity of coronary atherosclerosis was assessed by Gensini, Friesinger, and SYNTAX scores. RESULTS: Compared with non-diabetic patients, diabetic patients had lower serum adropin level and higher Gensini, Friesinger and SYNTAX scores (all p<0.001). Serum adropin level was inversely correlated with the Gensini, Friesinger and SYNTAX scores (rs=-0.389, -0.390 and -0.386, respectively, all p<0.001) among all patients. Low adropin level was an independent predictor of clinically relevant coronary atherosclerosis (SYNTAX score >11), both in diabetic patients [odds ratio (OR) 0.66, 95% confidence interval (CI) 0.53-0.83; p<0.001] and in non-diabetic patients (OR 0.51, 95% CI 0.35-0.74; p<0.001). CONCLUSIONS: Serum adropin level was significantly lower in type 2 diabetic patients than in non-diabetic patients and was inversely and independently associated with angiographic severity of coronary atherosclerosis, suggesting that serum adropin serves as a novel predictor of coronary atherosclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2013-0844

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Wu, L., Fang, J., Chen, L., Zhao, Z., Luo, Y., Lin, C., & Fan, L.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2014-01-01
Volume
52
Issue
5
Pages
751-8
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W1989840237
Cited by
162
References
2
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low serum adropin is associated with coronary atherosclerosis in type 2 diabetic and non-diabetic patients. https://app.cochat.ai/papers/10.1515/cclm-2013-0844
The paper
Wu, L., Fang, J., Chen, L., Zhao, Z., Luo, Y., Lin, C., & Fan, L. (2014). Low serum adropin is associated with coronary atherosclerosis in type 2 diabetic and non-diabetic patients. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm-2013-0844

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.