Proposal for the modification of the conventional model for establishing performance specifications
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Appropriate quality of test results is fundamental to the work of the medical laboratory. How to define the level of quality needed is a question that has been subject to much debate. Quality specifications have been defined based on criteria derived from the clinical applicability, validity of reference limits and reference change values, state-of-the-art performance, and other criteria, depending on the clinical application or technical characteristics of the measurement. Quality specifications are often expressed as the total error allowable (TE
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0067 · Cited by 563
Self-citationCriteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Cited by
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
Defining analytical performance specifications 15 years after the Stockholm conference
Panteghini, M., & Sandberg, S. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0303 · Cited by 79
“The validity of reference limits and reference change values are central to this model [17].”
BackgroundSelf-citationUseful measures and models for analytical quality management in medical laboratories
Westgard, J. O. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0710 · Cited by 64
Total error vs. measurement uncertainty: revolution or evolution?
Oosterhuis, W. P., & Theodorsson, E. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0997 · Cited by 57
Analytical performance specifications in clinical chemistry: the holy grail?
Oosterhuis, W. P. (2017) · Journal of Laboratory and Precision Medicine · doi:10.21037/jlpm.2017.09.02 · Cited by 16
“In this model the analytical variation is included as it was when the reference ranges were determined or confirmed (19).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Oosterhuis, W. P., & Sandberg, S.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 6
- Pages
- 925-37
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2077335718
- Cited by
- 26
- References
- 3
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.