Analytical performance specifications in clinical chemistry: the holy grail?

Open access
Oosterhuis, Wytze P.·2017·Journal of Laboratory and Precision Medicine

Abstract

The conference in Milan in 2014 resulted in a consensus statement on quality specifications. An EFLM Task and Finish Group was started to deal with issues that remained unresolved and needed further development including total analytical error methods. Most importantly were questions concerning measurement uncertainty (MU) and flaws in the model for calculating the permissible (or allowable) total error (TE). This is related to performance specifications based on biological variation, the second model of the Milan consensus. Performance specifications are closely linked to the work of Westgard and the concept of TE, that depends on the combined effect of the random and systematic errors of the method which is compared to a permissible TE that is in most cases based on biological variation. Where the first models for performance specifications did not include bias, later models did. The concept of bias is however complicated, both in the estimation of the value, and in the integration of bias in a mathematical model. In many fields outside clinical chemistry, the error concept has been abandoned in favour of the MU model. Bias is commonly excluded from this model, where only the uncertainty of bias is taken into account. There is no general consensus on these issues, and challenges remain to integrate the different concepts, both for the definition of performance, of performance specifications as for quality control procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/jlpm.2017.09.02

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Oosterhuis, W. P.
Affiliations
Zuyderland Medisch Centrum (NL)
Corresponding author
Oosterhuis, Wytze P.
Venue
Journal of Laboratory and Precision Medicine
Published
2017-09
Volume
2
Pages
78-78
ISSN
2519-9005 (ISSN-L)
OpenAlex
W2758988133
Cited by
16
References
22
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 3 · 2021: 3 · 2020: 1 · 2019: 3
FWCI
0.81
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
Journal of Laboratory and Precision Medicine (publishedVersion, cc-by-nc-nd)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
analytical performance specifications, total error, measurement uncertainty, biological variation, total allowable error, bias, Westgard rules, quality control, clinical chemistry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review