Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine
Open accessThe DOI matches its Crossref record.
Abstract
Article Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine was published on May 1, 2015 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 53, issue 6).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Of these, biological variation and state-of-the-art models are the mainstay of defining APS, as there are only limited studies that have examined the effects of APS on clinical outcomes or medical decisions.”
From Thyroid Stimulating Hormone and Thyroid Hormones (Triiodothyronine and Thyroxine): An American Thyroid Association-Commissioned Review of Current Clinical and Laboratory Status (2023) · cites this paper as [95]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To prevent inaccurate measurements affecting clinical decision making, analytical performance specifications (APSs) have been established to safeguard assay performance.”
The cited source says what the claim attributes to it.
In the citing paper
“APS can be based on (1) clinical outcome studies and the impact on clinical decision- making (Models 1a and 1b, respectively); (2) biological variation (Model 2); (3) or state-of-the-art laboratory performance (Model 3).95”
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Moreover, increased serum TG concentrations can also be found in subjects with other thyroid diseases, such as thyroiditis, increased thyroid activity, goiter, or Graves' disease [4,34].”
From European Biological Variation Study (EuBIVAS): within- and between-subject biological variation estimates for serum thyroid biomarkers based on weekly samplings from 91 healthy participants (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredIn the citing paper
“Availability of reliable biological variation (BV) data [3] for these central thyroid markers is important to define analytical performance specifications (APS) [4,5], and necessary to establish the reference change value (RCV), that may be used as a tool for monitoring patients in assessing what changes between two measurements can be explained by biological and analytical variation [6].”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Still being checked.
Cited by
Items 201–300 of 571
Soh, S. X., Loh, T. P., Sethi, S. K., & Ong, L. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0979 · Cited by 15
Díaz–Garzón, J., Fernández–Calle, P., Aarsand, A. K., Sandberg, S., Coşkun, A., Carobene, A., Jonker, N., Itkonen, O., Bartlett, W. A., & Soto, A. B. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0910 · Cited by 16
Self-citationBorrillo, F., & Panteghini, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0069 · Cited by 15
Self-citationEnko, D., Mangge, H., Münch, A., Niedrist, T., Mahla, E., Metzler, H., & Prüller, F. (2017) · Biochemia Medica · doi:10.11613/bm.2017.023 · Cited by 15
Kim, S., Chang, J., Kim, S., Park, S., Huh, J., & Jeong, T. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0454 · Cited by 17
Analytical quality performance goals for symmetric dimethylarginine in cats
Baral, R. M., Freeman, K. P., & Flatland, B. (2021) · Veterinary Clinical Pathology · doi:10.1111/vcp.12951 · Cited by 15
Biological variation – eight years after the 1st Strategic Conference of EFLM
Sandberg, S., Carobene, A., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0086 · Cited by 15
Self-citationFei, Y., Kang, F., Wang, W., Zhao, H., He, F., Zhong, K., Wang, Z., & Chen, W. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0958 · Cited by 15
Falay, M., Şeneş, M., Korkmaz, S., Turhan, T., Okay, M., Öztürk, B. A., Yücel, D., & Özet, G. (2018) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12910 · Cited by 15
Coşkun, A. (2025) · Annals of Laboratory Medicine · doi:10.3343/alm.2024.0569 · Cited by 14
Marzana, I., Escuer, M. I., Díaz, M. A. L., Barba, N., Kirchner, M. J. A., Espartosa, D. M., Alemany, M. V., Castro, I. G., Amaro, M. S., Lanzarote, J. J. P., et al. (2019) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2019.01.003 · Cited by 14
Reducing Lipid Panel Error Allowances to Improve the Accuracy of Cardiovascular Risk Stratification
Cole, J., Sampson, M. L., van Deventer, H. E., & Remaley, A. T. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad109 · Cited by 14
Lot change for reagents and calibrators
Don-Wauchope, A. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.003 · Cited by 14
Opportunities and drawbacks of nonstandard body fluid analysis
Lippi, G., & Plebani, M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0862 · Cited by 14
Kallner, A., Petersmann, A., Nauck, M. A., & Theodorsson, E. (2020) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2020.1716266 · Cited by 14
Evaluation of a new point-of-care testing for creatinine and urea measurement
Bargnoux, A., Kuster, N., Sutra, T., Laroche, L., Rodriguez, A., Morena-Carrere, M., Chénine, L., Chalabi, L., Dupuy, A., Badiou, S., et al. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1914344 · Cited by 14
Rotgers, E., Linko, S., Theodorsson, E., & Kouri, T. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117233 · Cited by 15
Huysal, K., & Budak, Y. (2015) · Biochemia Medica · doi:10.11613/bm.2015.042 · Cited by 13
Validation and regulation of point of care devices for medical applications
Misra, S., Huddy, J., Hanna, G. B., & Oliver, N. S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100072-4.00002-2 · Cited by 19
Pre-analytical considerations for the analysis of uracil and 5,6-dihydrouracil in heparin plasma
Capiau, S., Landschoot, A. V., Reyns, T., & Stepman, H. C. M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0921 · Cited by 13
Lot-to-lot variation and verification
Loh, T. P., Markus, C., Tan, C. H., Tran, M. T. C., Sethi, S. K., & Lim, C. Y. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1126 · Cited by 15
Selby, P. J., Banks, R. E., Gregory, W. M., Hewison, J., Rosenberg, W. M., Altman, D. G., Deeks, J. J., McCabe, C. J., Parkes, J., Sturgeon, C. M., et al. (2018) · Programme Grants for Applied Research · doi:10.3310/pgfar06030 · Cited by 16
Assay Stability, the missing component of the Error Budget
Mackay, M. A., Hegedus, G., & Badrick, T. C. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.07.004 · Cited by 13
Pradella, M. (2020) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.23736/s1825-859x.19.00025-2 · Cited by 13
Managing biological variation data: modern approaches for study design and clinical application
Johnson, P. R., Shahangian, S., & Astles, J. R. (2021) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2021.1932718 · Cited by 14
Peersman, N., Elslande, J. V., Lepage, Y., De Amicis, S., Desmet, K., & Vermeersch, P. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1237 · Cited by 12
“As the concept that analytical specifications should be based on biological variation characteristics is widely recommended, we considered these desirable criteria as an important benchmark for analytical precision throughout this article [27, 28].”
BackgroundBioVar: an online biological variation analysis tool.
Korkmaz, S., Zarasız, G., Göksülük, D., Senes, M., Sönmez, C., & Yucel, D. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0437 · Cited by 12
Greaves, R. F., Jolly, L., Hartmann, M. F., Ho, C. S., Kam, R. K. T., Joseph, J., Boyder, C., & Wudy, S. A. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0394 · Cited by 12
Trenti, T., Petrini, A. M., & Plebani, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0168 · Cited by 12
Clinical vs. statistical significance: considerations for clinical laboratories
Hakan, H., Tran, M. T. C., Markus, C., Ho, C. S., Loh, T. P., Zakaria, R., Cooke, B. R., Theodorsson, E., & Greaves, R. F. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0219 · Cited by 12
Torlakovic, E., Dieri, R. A., Badrick, T. C., Chen, Z. E., Cheung, C. C., Deans, Z. C., Dodson, A. R., Fenizia, F., Kijima, H., Maas, J., et al. (2025) · Archiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · doi:10.1007/s00428-025-04169-4 · Cited by 12
Automated data analytics workflow for stability experiments based on regression analysis
Geistanger, A., Braese, K., & Laubender, R. P. (2022) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2022.01.001 · Cited by 12
Özdemir, Ş., & Uçar, F. (2022) · Journal of Laboratory Medicine · doi:10.1515/labmed-2021-0116 · Cited by 16
Defining allowable total error limits in the clinical laboratory
Palmer, J., & Galior, K. D. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.11.006 · Cited by 13
External Quality Assessment in Croatia: problems, challenges, and specific circumstances
Krleža, J. L., Ćelap, I., & Tanasković, J. V. (2017) · Biochemia Medica · doi:10.11613/bm.2017.011 · Cited by 14
Birindelli, S., Aloisio, E., Carnevale, A., Brando, B., Dolci, A., & Panteghini, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1176 · Cited by 12
Self-citationBiological variation of peripheral blood T-lymphocytes
Falay, M., Şeneş, M., Korkmaz, S., Zararsız, G., Turhan, T., Okay, M., Yücel, Ç., Kılınçkaya, M. F., Özet, G., & Yücel, D. (2019) · Journal of Immunological Methods · doi:10.1016/j.jim.2019.04.002 · Cited by 13
Performance specifications and six sigma theory: Clinical chemistry and industry compared
Oosterhuis, W. P., & Severens, M. J. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.04.002 · Cited by 14
Self-citationIs there a classical role for the clinical laboratory in digital health?
Ceriotti, F. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0603 · Cited by 13
Quality Monitoring of a FIT-Based Colorectal Cancer Screening Program
Toes‐Zoutendijk, E., Bonfrèr, J. M. G., Ramakers, C. R. B., Thelen, M., Spaander, M. C. W., Dekker, E., van der Meulen, M. P., Buskermolen, M., van Vuuren, A. J., Kuipers, E. J., et al. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2018.294041 · Cited by 12
Analytical performance specifications – moving from models to practical recommendations
Sandberg, S., Zima, T., & Panteghini, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0661 · Cited by 11
Self-citationWise, S. A., Cavalier, E., Lukas, P., Peeters, S. D., Goff, C. M. L., Briggs, L. E., Williams, E. L., Mineva, E. M., Pfeiffer, C. M., Vesper, H. W., et al. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05699-7 · Cited by 11
A second-derivate fitting algorithm for the quantification of free hemoglobin in human plasma
Paal, M., Lang, A., Hennig, G., Buchholtz, M., Sroka, R. C., & Vogeser, M. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.04.007 · Cited by 13
Li, C., Wang, Y., Lü, H., Du, Z., Xu, C., & Peng, M. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0741 · Cited by 11
Panteghini, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0900 · Cited by 11
Self-citationThe application of Six Sigma to perform quality analyses of plasma proteins
Yang, F., Wang, W., Liu, Q., Wang, X., Bian, G., Teng, S., & Liang, W. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219892023 · Cited by 11
Ricós, C., Fernández–Calle, P., Marqués-García, F., Minchinela, J., Salas, Á., Martínez-Brú, C., Boned, B., Rioja, R. G., Cortés, M., González-Lao, E., et al. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0008 · Cited by 11
Dirks, N. F., Ackermans, M. T., Martens, F., Cobbaert, C. M., de Jonge, R., & Heijboer, A. C. (2020) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.12.020 · Cited by 11
Importance of implementing an analytical quality control system in a core laboratory
Marqués-García, F., García-Codesal, M. F., Caro-Narros, M. R., & Sanfeliciano, T. C. (2015) · Revista de Calidad Asistencial · doi:10.1016/j.cali.2015.07.007 · Cited by 11
State-of-the-art Approach to Goal Setting
Salas, A., Ricós, C., Prada, E., Ramón, F., Zaragoza, J. M. M., Jou, J. M., & Blazquez, R. (2016) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.007 · Cited by 11
Proposed Imprecision Quality Goals for Urinary Albumin/Creatinine Ratio
Ko, D., Lee, S. W., Hyun, J., Kim, H. S., Park, M.-J., & Shin, D. H. (2018) · Annals of Laboratory Medicine · doi:10.3343/alm.2018.38.5.420 · Cited by 12
Hollestelle, M. J., Kristoffersen, A. H., Idema, R. N., Meijer, P., Sandberg, S., de Maat, M. P. M., & Aarsand, A. K. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1207 · Cited by 10
Self-citationChristensen, S. H., Kirk, F. T., Gyldenholm, T., Munk, D. E., Hjerrild, B., Kvistgaard, H., Christensen, L. D., Sandahl, T. D., & Abildgaard, A. M. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119978 · Cited by 10
An overview of EFLM harmonization activities in Europe
Kilpatrick, E. S., & Sandberg, S. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0098 · Cited by 11
Self-citationJudging the clinical suitability of analytical performance of cardiac troponin assays
Krintus, M., & Panteghini, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0027 · Cited by 10
Self-citationTang, N., Jin, X., Sun, Z., & Jian, C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2016.1271906 · Cited by 11
Korchia, J., & Freeman, K. P. (2022) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/10406387221076129 · Cited by 10
Commutability of Reference Materials for α-Fetoprotein in Human Serum
Yue, Y., Zhang, S., Xu, Z., Chen, X., & Wang, Q. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0441-oa · Cited by 10
Cavalier, E., Bhattoa, H. P., Heijboer, A. C., Lombardi, G., Delatour, V., Uytfanghe, K. V., Makris, K., Jørgensen, N. R., Herrmann, M., Pikner, R., et al. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0554 · Cited by 10
Self-citationEstablishing Pragmatic Analytical Performance Specifications for Blood Beta-Hydroxybutyrate Testing
Kilpatrick, E. S., Butler, A. E., Atkin, S. L., & Sacks, D. B. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad020 · Cited by 10
Use of dried blood spots for monitoring inflammatory and nutritional biomarkers in the elderly
Vialaret, J., Vignon, M., Hirtz, C., Badiou, S., Baptista, G., Fichter, L., Dupuy, A., Maceski, A. M., Fayolle, M., Brousse, M., et al. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0312 · Cited by 9
Wang, W., Zhang, Z., Zhang, C., Zhao, H., Yuan, S., Liu, J., Dong, N., Wang, Z., & Kang, F. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.0236 · Cited by 10
A New Concept for Reference Change Values—Regression to the Population Mean
Jones, G. R. D., Aarsand, A. K., Carobene, A., Coşkun, A., Fernández–Calle, P., Bartlett, W. A., Díaz–Garzón, J., & Sandberg, S. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae067 · Cited by 9
Self-citationChai, J. H., Flatman, R., Teis, B., Sethi, S. K., Badrick, T. C., & Loh, T. P. (2019) · Pathology · doi:10.1016/j.pathol.2018.12.418 · Cited by 9
Gils, C., Sandberg, M. B., & Nybo, M. (2020) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2020.1818281 · Cited by 9
Advances in internal quality control
Loh, T. P., Lim, C. Y., Sethi, S. K., Tan, R. Z., & Markus, C. (2023) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2023.2209174 · Cited by 14
Comins‐Boo, A., Pérez-Pla, F., Irure‐Ventura, J., López‐Hoyos, M., Blanco-Peris, L., Alonso, M. D. C. M., & Segundo, D. S. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0470 · Cited by 9
Diederiks, N. M., Ruhaak, L. R., Romijn, F. P. H. T. M., Pieterse, M., Smit, N. P. M., & Cobbaert, C. M. (2024) · Clinical Proteomics · doi:10.1186/s12014-023-09446-5 · Cited by 9
Braga, F., Infusino, I., Frusciante, E., Ceriotti, F., & Panteghini, M. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2018.297655 · Cited by 9
Self-citationImpact of analytical bias on machine learning models for sepsis prediction using laboratory data
Yeşil, M. R., Talli, I., Pelloso, M., Cosma, C., Pangrazzi, E., Plebani, M., Üstündağ, Y., & Padoan, A. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0491 · Cited by 8
Lim, Y. K., & Cha, Y. J. (2017) · Laboratory Medicine Online · doi:10.3343/lmo.2017.7.2.66 · Cited by 8
Theodorsson, E. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1208 · Cited by 10
Schierscher, T., Salzmann, L., Singh, N., Bachmann, M., Kobel, A., Wild, J., Bauland, F., Geistanger, A., Risch, L., Geletneky, C., et al. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1104 · Cited by 8
Reliable biological and multi-omics research through biometrology
Dong, L., Zhang, Y., Fu, B., Swart, C., Jiang, H., Liu, Y., Huggett, J. F., Wielgosz, R., Niu, C., Li, Q., et al. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05239-3 · Cited by 8
Cazzolla, A. P., Brescia, V., Lovero, R., Fontana, A., Giustino, A., Dioguardi, M., Comite, M. D., Serio, F. D., Ciavarella, D., & Crincoli, V. (2024) · Dentistry Journal · doi:10.3390/dj12070209 · Cited by 8
Commutability of possible external quality assessment materials for progesterone measurement
Yi, X., Wang, Y., Zhang, T., Zeng, J., Zhao, H., Zhou, W., Zhang, J., Yan, Y., Chen, W., & Zhang, C. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.10.012 · Cited by 8
Thuile, K., Giacomuzzi, K., Jani, E., Marschang, P., & Mueller, T. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1946844 · Cited by 9
Validation of an enzyme-linked immunosorbent assay for measurement of feline haptoglobin
Stiller, J., Jasensky, A., Hennies, M., Einspanier, R., & Kohn, B. (2016) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638716634397 · Cited by 10
Petrides, V., & Schneider, S. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020903 · Cited by 10
Hollestelle, M. J., Ruinemans‐Koerts, J., Idema, R. N., Meijer, P., & de Maat, M. P. M. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0934 · Cited by 11
The Role and Quality of Hb A1c: A Continuing Evolution
Sikaris, K. A. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.239319 · Cited by 8
Self-citationState of the art of measurement uncertainty of serum ferritin
Rovegno, L., Civera, E., Infusino, I., & Panteghini, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0711 · Cited by 9
Self-citationLoh, T. P., Tan, R. Z., Sethi, S. K., Lim, C. Y., & Markus, C. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.03.005 · Cited by 7
Nguyen, T. A., Kirubakaran, R., Schultz, H. B., Wong, S., Reuter, S. E., McMullan, B. J., Bolisetty, S., Campbell, C., Horvath, A. R., & STOCKER, S. L. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad036 · Cited by 8
Self-citationSun, D., McLean, D.-M. M., Palaty, J., & Konforte, D. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.120057 · Cited by 7
Lou, Y., Shan, Z., Chen, Q., & Kang, F. (2025) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.70036 · Cited by 7
Milinković, N., Jovičić, S. Ž., & Ignjatović, S. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1784838 · Cited by 10
A national surveillance program for evaluating new reagent lots in medical laboratories
Solsvik, A. E., Kristoffersen, A. H., Sandberg, S., Gidske, G., Stavelin, A. V., Eikeland, J., & Amundsen, E. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1262 · Cited by 7
Self-citationWrong Sigma metric causes chaos
Coşkun, A. (2022) · Journal of Laboratory Medicine · doi:10.1515/labmed-2022-0003 · Cited by 7
The problem with total error models in establishing performance specifications and a simple remedy
Krouwer, J. S. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1175 · Cited by 7
Category 1 external quality assessment program for serum creatinine
González-Lao, E., Díaz–Garzón, J., Corte, Z., Ricós, C., Perich, C., Álvarez, V., Simón, M. S., Minchinela, J., García-Lario, J. V., Boned, B., et al. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.03.70 · Cited by 7
Lack of grading agreement among international hemostasis external quality assessment programs
Olson, J. D., Jennings, I., Meijer, P., Bon, C., Bonar, R. A., Favaloro, E. J., Higgins, R. A., Keeney, M., Mammen, J., Marlar, R. A., et al. (2017) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000690 · Cited by 7
Instability of uracil in whole blood might affect cancer treatment with fluoropyrimidines
Tybirk, L., Hoffmann, E., & Greibe, E. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.10.017 · Cited by 7
Effects of sample matrix in the measurement of antithrombin by LC-MS: A role for immunocapture
Kruijt, M., Smit, N. P. M., van Ham, J. J., Cobbaert, C. M., & Ruhaak, L. R. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2023.01.002 · Cited by 7
How clinical laboratories select and use Analytical Performance Specifications (APS) in Italy
Ceriotti, F., Buoro, S., & Pasotti, F. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1314 · Cited by 8
Studies of instrument/method comparison, as part of validation for use in veterinary species
Freeman, K. P., & Flatland, B. (2017) · Veterinary Clinical Pathology · doi:10.1111/vcp.12455 · Cited by 8
Short- and long-term stability of synovial fluid calprotectin
Čičak, H., Bulat, S., Jelicic, J., Ivković, A., Radončić, K. M., Biljak, V. R., Dukić, L., & Šimundić, A.-M. (2024) · Biochemia Medica · doi:10.11613/bm.2024.030704 · Cited by 6
Aslan, B., Carobene, A., Jonker, N., Galior, K. D., Boned, B., Marqués-García, F., Ricós, C., Bartlett, W. A., Coşkun, A., Díaz–Garzón, J., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.120032 · Cited by 7
Self-citationIannone, F., Angotti, E., Lucia, F., Martino, L., Antico, G. C., Galato, F., Aversa, I., Gallo, R., Giordano, C., Abatino, A., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.117863 · Cited by 7
Zhang, C., Yan, Y., & Zhang, C. (2024) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/j.jtemb.2024.127451 · Cited by 6
Metadata
- Authors
- Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M.
- Affiliations
- University of Bergen (NO)
- University of Dundee (GB)
- The University of Sydney (AU)
- Radboud University Nijmegen (NL)
- St Vincent's Hospital Sydney (AU)
- Atrium Medisch Centrum Parkstad (NL)
- European Commission (BE)
- The University of Melbourne (AU)
- University of Milan (IT)
- Corresponding author
- Sandberg, Sverre
- ORCID
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 6
- Pages
- 833-5
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1985103439
- Cited by
- 563
- References
- 0
- Citations by year
- 2026: 55 · 2025: 49 · 2024: 59 · 2023: 62 · 2022: 46 · 2021: 34 · 2020: 45 · 2019: 41 · 2018: 63 · 2017: 52 · 2016: 40 · 2015: 16
- FWCI
- 41.99
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Discovery Research Portal (University of Dundee) (submittedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- analytical performance specifications, analytical performance, clinical laboratory quality, consensus statement
- MeSH terms
- Laboratories, Societies, Medical, Clinical Laboratory Techniques, Consensus, Laboratory Proficiency Testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.