Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing’s syndrome
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Article Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing’s syndrome was published on March 1, 2017 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 55, issue 3).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The diagnosis of Cushing's syndrome: an Endocrine Society Clinical Practice Guideline.
Nieman, L. K., Biller, B. M. K., Findling, J. W., Newell-Price, J., Savage, M. O., Stewart, P. M., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0125 · Cited by 2,718 · cited 3×
“In fact, determination of late-night salivary cortisol concentration is recommended for the screening of patients with suspected Cushing’s syndrome (CS) [2].”
BackgroundMethodInfluentialHansen, Å. M., Garde, A. H., & Persson, R. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510701819127 · Cited by 198
Comparison of salivary cortisol as measured by different immunoassays and tandem mass spectrometry
Miller, R., Plessow, F., Rauh, M., Gröschl, M., & Kirschbaum, C. (2013) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2012.04.019 · Cited by 181 · cited 1×
“Several studies have shown that it is necessary to establish cut-off values for salivary cortisol measurement in CS diagnosis, according to the method used [7].”
Method
Cited by
Accuracy of laboratory tests for the diagnosis of Cushing syndrome
Galm, B. P., Qiao, N., Klibanski, A., Biller, B. M. K., & Tritos, N. A. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa105 · Cited by 100
Ceccato, F., Marcelli, G., Martino, M., Concettoni, C., Brugia, M., Trementino, L., Michetti, G., & Arnaldi, G. (2019) · Journal of Endocrinological Investigation · doi:10.1007/s40618-018-0921-1 · Cited by 38
Biochemical diagnosis of Cushing’s disease: Screening and confirmatory testing
Petersenn, S. (2021) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2021.101519 · Cited by 33
Influence of age, gender and body mass index on late-night salivary cortisol in healthy adults
Coelli, S., Farias, C. B., Soares, A. A., Crescente, G. M., Hirakata, V. N., Souza, L. B., Czepielewski, M. A., Camargo, J. L., & Silveiro, S. P. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1100 · Cited by 19
Metadata
- Authors
- Repetto, E. M., Gonzalez, D., Jacobsen, D., Smithuis, F., Jamardo, J., Cano, M., Aranda, C., Oneto, A., Berg, G., & Fabre, B.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-01-01
- Volume
- 55
- Issue
- 3
- Pages
- e65-e68
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2515443191
- Cited by
- 10
- References
- 3
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing’s syndrome. https://app.cochat.ai/papers/10.1515/cclm-2016-0585
- The paper
- Repetto, E. M., Gonzalez, D., Jacobsen, D., Smithuis, F., Jamardo, J., Cano, M., Aranda, C., Oneto, A., Berg, G., & Fabre, B. (2017). Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing’s syndrome. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2016-0585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.