The DOI matches its Crossref record, with a small difference in title or year; 18 of the 18 references it cites were found in a registry or an index.
Recommendation for the review of biological reference intervals in medical laboratories
Abstract
This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For decision thresholds it is unnecessary to validate them in the laboratory [97].”
From Quantifying atherogenic lipoproteins for lipid-lowering strategies: Consensus-based recommendations from EAS and EFLM (2020) · cites this paper as [97]
In the citing paper
“If ≤ 2 of 20 values (≤10%) fall outside the reference interval then the interval can be adopted [96,97].”
From Quantifying atherogenic lipoproteins for lipid-lowering strategies: Consensus-based recommendations from EAS and EFLM (2020) · cites this paper as [97]
Citations
Cites
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90151-3 · Cited by 395
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90224-5 · Cited by 222
Adeli, K., Raizman, J. E., Chen, Y., Higgins, V., Nieuwesteeg, M., Abdelhaleem, M., Wong, S. L., & Blais, D. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.240531 · Cited by 185
Adeli, K., Higgins, V., Nieuwesteeg, M., Raizman, J. E., Chen, Y., Wong, S. L., & Blais, D. R. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.240515 · Cited by 161
Petitclerc, C., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90150-1 · Cited by 141
Solberg, H. E., & Petitclerc, C. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90074-5 · Cited by 109
Özarda, Y., Ichihara, K., Barth, J. H., & Klee, G. G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0249 · Cited by 109
Vassault, A. J., Grafmeyer, D., de Graeve, J., Cohen, R., Beaudonnet, A., & Bienvenu, J. (1999) · PubMed · Cited by 106
Self-citationDybkœr, R., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90152-5 · Cited by 87
Serum Creatinine and Glomerular Filtration Rate: Perception and Reality
Dalton, R. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.144261 · Cited by 81
Research works printed but not linked: 5
- Siest G, Vernet-Nyssen M. Le concept de valeurs de référence en biologie clinique. Document A, 2ème version. Ann Biol Clin 1981;39:381–4.
- CLSI Document C28-A3c:2008. Defining, establishing and verifying reference intervals in the clinical laboratory; approved guideline, 3rd ed. Wayne, PA, 2008;28:61.
- Horn PS, Pesce A-J. Reference intervals. A user’s guide – Washington, DC: AACC Press, 2005.
- Vassault and the members of the French Society of Clinical Biology (SFBC). Protocole for the validation of methods (VALTEC protocol). Ann Biol Clin 1986;44:686–745.
- approved guideline - 3rd ed. Wayne, PA, 2013;22:55.
Cited by
Items 101–118 of 118
Liquid gold: Cerebrospinal fluid collection, composition and biomarkers
Tigchelaar, C. (2025) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.1275767740
Plekhanova, O., Цвиренко, С. В., Kiyaev, A. V., & Иосифович, С. Л. (2025) · Laboratory Service · doi:10.17116/labs20251401121
The S model: Method performance specifications based on Six Sigma metrics
Huba, P., Vaňuga, A., & Dancova, K. (2017) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2017.027
Nilai Rujukan Darah Rutin Dewasa Sehat di Kota Yogyakarta
Faruq, Z. H., Nuryani, S., Sistiyono, S., & Rahmawati, U. (2025) · Health Information Jurnal Penelitian · doi:10.36990/hijp.v17i1.1471
“Selain itu variasi dari alat ukur yang digunakan harus dapat dideskripsikan dan dikendalikan (Ceriotti, Hinzmann, and Panteghini 2009; Henny et al. 2016).”
Asafa, M. A., Ahmed, I. O., Agim, M. B., Fabinu, T. A., Kusoro, S. O., Ogunoye, B. T., Ogunlade, O., & Bolarinwa, R. A. (2025) · BMC Research Notes · doi:10.1186/s13104-025-07303-2
“Reference interval takes into account the age, sex, ethnicity and patient population [17].”
Schulenburg‐Brand, D., Peek, R., Bentley, L., Swingler, R., Pavlova, Y. T., Dawe, R. S., & McGuire, V. A. (2025) · British Journal of Haematology · doi:10.1111/bjh.20252
Yasui, M., Ogihara, T., Yamaoka, S., Shinohara, J., Kawamura, Y., Kijima, M., Fukuda, Y., Nishioka, D., Ito, Y., & Ashida, A. (2025) · Pediatric Pulmonology · doi:10.1002/ppul.71182
“To calculate RIs, it is essential to ensure that the reference subject is healthy and free of the target disease [10, 11].”
Additional file 1 of Comprehensive reference intervals for white blood cell counts during pregnancy
Zhu, J., Li, Z., Deng, Y., Lan, L., & Yang, J. (2024) · Figshare · doi:10.6084/m9.figshare.24953151
Ma, C., Hou, L., Zou, Y., Ma, X., Wang, D., Hu, Y., Song, A., Cheng, X., & Qiu, L. (2022) · Figshare · doi:10.6084/m9.figshare.21376288
Laboratory data mining: monitoring of the local applicability of prolactin reference interval
Xiang, S., Jinwen, Z., Chen, W., & Wang, Q. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.120889
TSH reference intervals among Sub-Saharan African adults: a pilot study in Cameroon
Mbouna, S. F. M., Marcelle-Nourya Ymelong, M. E. L. I., EDINGA, B. E., ATABE, N. N., Stéphanie, Z. I. B. I., BETALA, M., Jean Maximilien, T. A. N. G., TANG-LIKENG, D. C., MFEKEU-KUATE, L., & Ama-Moor, V. J. (2026) · BMC Endocrine Disorders · doi:10.1186/s12902-026-02295-x
“The efficacy of this method has been demonstrated in several studies, which have shown it to exhibit superior sensitivity and specificity when compared with radioimmunoassays [8–12].”
InfluentialZhou, C., Wu, X., Tian, Z., Li, M., Liu, F., & Li, J. (2026) · BMC Geriatrics · doi:10.1186/s12877-026-07560-1
“…(IFCC) and the Clinical and Laboratory Standards Institute (CLSI) recommend establishing locally derived, population-specific reference intervals [46, 47], well-defined, elderly specific diagnostic thresholds remain limited, particularly in China, which faces the dual challenges of limited…”
Reference interval of Serum 25-Hydroxyvitamin D of adult Bangladeshi population
Haque, W. M. M. U., Pathan, M., & Sayeed, M. A. (2026) · IMC Journal of Medical Science · doi:10.55010/imcjms.20.006
The total mass, copy number, and distribution of hormones in the human bloodstream
Sender, R., Kedar, T., Navon, Y., Raz, M., Bikel, S., Hemi, R., Milo, R., & Fuchs, S. (2026) · PLoS Biology · doi:10.1371/journal.pbio.3003864
Tatsuoka, Y., Longley, M., MacCarter, D., & Carr, Z. J. (2026) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.70076
“This aligns with current recommendations for data ‐ driven reference interval estimation from routine data (Henny et al., 2016).”
IOF-IFCC international survey of global laboratory practices for bone status indices
Cavalier, E., Kapoula, G., Bhattoa, H. P., Lombardi, G., Makris, K., Jørgensen, N. R., Reid, M. S., Dinçel, A. S., Pikner, R., & Vasikaran, S. D. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0941
“…in use, whether manufacturer-provided or locally established, particularly when assay calibration, standardization, or manufacturer recommendations evolve, and more generally in line with recommendations that reference intervals should be appropriately veri fi ed and periodically reviewed [9].”
Tanaka, T., Oguri, T., Shimizu, T., Fujimoto, S., Shiga, M., Nagumo, Y., Kandori, S., Ikeda, A., Kojo, K., & Nishiyama, H. (2026) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-026-00968-2
Zhang, L., Hu, Q., Chen, Y., & Yuan, H. (2026) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.70315
“This approach avoids additional recruitment, reduces cost, leverages large existing datasets, and better reflects real-world clinical conditions [20].”
Metadata
- Authors
- Henny, J., Vassault, A., Boursier, G., Vukasovic, I., Mesko Brguljan, P., Lohmander, M., Ghita, I., Andreu, F. A. B., Kroupis, C., Sprongl, L., Thelen, M. H. M., Vanstapel, F. J. L. A., Vodnik, T., Huisman, W., & Vaubourdolle, M.
- Affiliations
- Inserm (FR)
- Executive manager, Asqualab, Paris, France
- Université de Montpellier (FR)
- University Department of Chemistry, Sestre Milosrdnice University Hospital Center, Zagreb Croatia
- Department of Clinical Chemistry, University Clinic for Respiratory and allergic Diseases Golnik, Golnik, Slovenia
- NU Hospital Group (SE)
- Synevo Central Lab Clinical trials, Iflov County, Romania
- Servicio de Analisis Clinicos, H.U. Principe de Asturias, Alcalá de Henares, Spain
- Department of Clinical Biochemistry, Attikon University General Hospital, University of Athens Medical School, Greece
- Central Laboratory, Sumperk Hospital a.s., Sumperk, Czech Republic
- Amphia Ziekenhuis (NL)
- Universitair Ziekenhuis Leuven (BE)
- Univerzitetski Klinički Centar Srbije (RS)
- Consultant European Specialist in Clinical Chemistry and Laboratory Medicine, The Hague, The Netherlands
- Assistance Publique – Hôpitaux de Paris (FR)
- Corresponding author
- Vaubourdolle, Michel
- ORCID
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-10-14
- Volume
- 54
- Issue
- 12
- Pages
- 1893-1900
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2530488227
- Cited by
- 119
- References
- 18
- Citations by year
- 2026: 14 · 2025: 13 · 2024: 15 · 2023: 13 · 2022: 10 · 2021: 11 · 2020: 17 · 2019: 11 · 2018: 6 · 2017: 9
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- reference limits, decision limits, reference population selection, analytical quality, terminology, CLSI guidelines, medical laboratories
- MeSH terms
- Chemistry, Clinical, Humans, Laboratories, Reference Standards, Clinical Laboratory Services
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.