Recommendation for the review of biological reference intervals in medical laboratories
The DOI matches its Crossref record, with a small difference in title or year; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For decision thresholds it is unnecessary to validate them in the laboratory [97].”
From Quantifying atherogenic lipoproteins for lipid-lowering strategies: Consensus-based recommendations from EAS and EFLM (2020) · cites this paper as [97]
In the citing paper
“If ≤ 2 of 20 values (≤10%) fall outside the reference interval then the interval can be adopted [96,97].”
From Quantifying atherogenic lipoproteins for lipid-lowering strategies: Consensus-based recommendations from EAS and EFLM (2020) · cites this paper as [97]
Citations
Cites
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90151-3 · Cited by 395
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90224-5 · Cited by 222
Adeli, K., Raizman, J. E., Chen, Y., Higgins, V., Nieuwesteeg, M., Abdelhaleem, M., Wong, S. L., & Blais, D. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.240531 · Cited by 185
Adeli, K., Higgins, V., Nieuwesteeg, M., Raizman, J. E., Chen, Y., Wong, S. L., & Blais, D. R. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.240515 · Cited by 161
Petitclerc, C., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90150-1 · Cited by 141
Solberg, H. E., & Petitclerc, C. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90074-5 · Cited by 109
Ozarda, Y., Ichihara, K., Barth, J. H., & Klee, G. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2013-0249 · Cited by 109
Vassault, A. J., Grafmeyer, D., de Graeve, J., Cohen, R., Beaudonnet, A., & Bienvenu, J. (1999) · PubMed · Cited by 106
Self-citationDybkœr, R., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90152-5 · Cited by 87
Serum Creatinine and Glomerular Filtration Rate: Perception and Reality
Dalton, R. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.144261 · Cited by 81
Research works printed but not linked: 5
- Siest G, Vernet-Nyssen M. Le concept de valeurs de référence en biologie clinique. Document A, 2ème version. Ann Biol Clin 1981;39:381–4.
- CLSI Document C28-A3c:2008. Defining, establishing and verifying reference intervals in the clinical laboratory; approved guideline, 3rd ed. Wayne, PA, 2008;28:61.
- Horn PS, Pesce A-J. Reference intervals. A user’s guide – Washington, DC: AACC Press, 2005.
- Vassault and the members of the French Society of Clinical Biology (SFBC). Protocole for the validation of methods (VALTEC protocol). Ann Biol Clin 1986;44:686–745.
- approved guideline - 3rd ed. Wayne, PA, 2013;22:55.
Cited by
Nordestgaard, B. G., Langlois, M. R., Langsted, A., Chapman, M. J., Aakre, K. M., Baum, H., Borén, J., Bruckert, E., Catapano, A., Cobbaert, C., et al. (2020) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2019.12.005 · Cited by 246
Langlois, M. R., Nordestgaard, B. G., Langsted, A., Chapman, M. J., Aakre, K. M., Baum, H., Borén, J., Bruckert, E., Catapano, A., Cobbaert, C., et al. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1253 · Cited by 211
“If ≤2 of 20 values (≤10%) fall outside the reference interval, then the interval can be adopted [96, 97].”
BackgroundMethodInfluentialMrazek, C., Keppel, M. H., Cadamuro, J., Haschke‐Becher, E., Oberkofler, H., Felder, T. K., & Lippi, G. (2020) · Biochemia Medica · doi:10.11613/bm.2020.020502 · Cited by 170
“In an EFLM WG-PRE observational study, phlebotomists failed to identify the patient according to Clinical and Laboratory Standards Institute (CLSI) or local guidelines in up to 16% of cases.”
MethodInfluentialMachine learning in laboratory medicine: waiting for the flood?
Cabitza, F., & Banfi, G. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0287 · Cited by 98
“However, because setting reference ranges is difficult, expensive and time consuming [43], reference ranges are generally collected from the literature or adopted from those suggested by the laboratory test manufacturers.”
BackgroundTimbrell, N. E. (2024) · British Journal of Biomedical Science · doi:10.3389/bjbs.2024.12339 · Cited by 83
“…Federation of Clinical Chemistry and Laboratory Medicine (IFCC) de fi nes a reference population as a group made up of “ reference individuals, ” which are individuals that have been selected based on a set of criteria such as medical history, physical examinations, or laboratory investigations [7].”
BackgroundBazarian, J. J., Zetterberg, H., Buki, A., Dengler, B. A., Diaz-Arrastia, R., Korley, F. K., Lazarus, R., Meier, T. B., Mondello, S., Moritz, K., et al. (2025) · Journal of Neurotrauma · doi:10.1089/neu.2024.0581 · Cited by 61
Haeckel, R., Wosniok, W., & Streichert, T. (2021) · Journal of Laboratory Medicine · doi:10.1515/labmed-2020-0131 · Cited by 49
“[78] pointed out that reference limits should be evaluated according to their confidence limits and stated that “it is generally accepted that the confidence interval for each reference limit be <0.”
BackgroundCritical comments to a recent EFLM recommendation for the review of reference intervals
Haeckel, R., Wosniok, W., Arzideh, F., Zierk, J., Gurr, E., & Streichert, T. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1112 · Cited by 46
“[1] which are not generally used according to our experience.”
BackgroundInfluentialReference interval of monocyte distribution width (MDW) in healthy blood donors
Agnello, L., Sasso, B. L., Bivona, G., Gambino, C. M., Giglio, R. V., Iacolino, G., Iacona, A., Mancuso, S., Ciaccio, A. M., Vidali, M., et al. (2020) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.07.036 · Cited by 47
Martínez-Sánchez, L. M., Marqués-García, F., Özarda, Y., Blanco, A., Brouwer, N., Canalías, F., Cobbaert, C. M., Thelen, M., & den Elzen, W. P. J. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0034 · Cited by 43
“According to the CLSI recommendation [2, 11], reference intervals should be calculated by selecting a minimum of 120 healthy individuals to be able to calculate 90% confidence intervals [12].”
MethodSelf-citationNeurogranin as a Reliable Biomarker for Synaptic Dysfunction in Alzheimer’s Disease
Agnello, L., Sasso, B. L., Vidali, M., Scazzone, C., Piccoli, T., Gambino, C. M., Bivona, G., Giglio, R. V., Ciaccio, A. M., Bella, V. L., et al. (2021) · Diagnostics · doi:10.3390/diagnostics11122339 · Cited by 46
“Thus, the RI established in our study can be transferred to other laboratories only after appropriate verification [28].”
MethodSasso, B. L., Vidali, M., Scazzone, C., Agnello, L., & Ciaccio, M. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0957 · Cited by 41
“The direct approach for estimation of new RIs was proposed as the “gold standard” [11] and it is often applied in the estimation and validation of RIs for new biomarkers [12–14].”
MethodStukas, S. K., Higgins, V., Frndova, H., Gill, J., Hubara, E., Guerguerian, A., Boutis, K., Beauchamp, M. H., FARRELL, C. A., Babl, F. E., et al. (2019) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(19)30194-4 · Cited by 41
Reference values of trace elements in blood and/or plasma in adults living in Belgium
Hoet, P., Jacquerye, C., Deumer, G., Lison, D., & Haufroid, V. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1019 · Cited by 32
HOFFMANN, G. E., Klawitter, S., Trulson, I., Adler, J., Holdenrieder, S., & Klawonn, F. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13154397 · Cited by 30
“Due to the specifications in the guideline [2], it has become common practice to consider a sample size of 120 values as a minimum [9,25,26].”
MethodTozzoli, R., D’Aurizio, F., Metus, P., Steffan, A., Mazzon, C., & Bagnasco, M. (2018) · Journal of Endocrinological Investigation · doi:10.1007/s40618-018-0825-0 · Cited by 29
Establishing reference intervals in the coagulation laboratory
Castellone, D. D. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12661 · Cited by 29
Current theory and practice of reference interval36
Evgina, S. A., & Saveliev, L. I. (2019) · Laboratory Service · doi:10.17116/labs2019802136 · Cited by 27
Hu, L.-H., Sharir, T., Miller, R. J. H., Einstein, A. J., Fish, M. B., Ruddy, T. D., Dorbala, S., Carli, M. F. D., Kaufmann, P. A., Sinusas, A. J., et al. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01730-y · Cited by 26
Sarmanova, A., Hall, M. C., Fernandes, G., Valdes, A. M., Walsh, D. A., Doherty, M., & Zhang, W. (2018) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2018.09.018 · Cited by 28
A combined approach to generate laboratory reference intervals using unbalanced longitudinal data
Vogel, M., Kirsten, T., Kratzsch, J., Engel, C., & Kieß, W. (2017) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2017-0171 · Cited by 25
Björndahl, L. (2022) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2022.03.011 · Cited by 29
Özcürümez, M. K., Haeckel, R., Gurr, E., Streichert, T., & Sack, U. (2019) · Journal of Laboratory Medicine · doi:10.1515/labmed-2018-0500 · Cited by 23
Comprehensive reference intervals for white blood cell counts during pregnancy
Zhu, J., Li, Z., Deng, Y., Lan, L., & Yang, J. (2024) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-023-06227-8 · Cited by 23
“In our study, which involved a large population, the sample size for gestational age 5 weeks did not reach the minimum requirement of at least 120 participants needed for accurate estimation of reference limits [21].”
BackgroundData mining of reference intervals for coagulation screening tests in adult patients
Zierk, J., Ganslandt, T., Rauh, M., Metzler, M., & Strasser, E. F. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.09.006 · Cited by 23
Santen, R. J., Pinkerton, J. V., LIU, J. H., Matsumoto, A. M., Lobo, R. A., Davis, S. R., & Simon, J. A. (2020) · Menopause The Journal of The North American Menopause Society · doi:10.1097/gme.0000000000001556 · Cited by 28
“Before the workshop, several factors in developing reference ranges were identified for discussion, including the type of population to be used; identification of sensitive, accurate, and standardized estradiol assays; and use of direct versus indirect methods for reference range development.(4)”
MethodIndirect method for validating transference of reference intervals
Lykkeboe, S., Nielsen, C. G., & Christensen, P. A. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0574 · Cited by 21
“We also find our indirect method fit for reviewing or validating current RIs [21, 22].”
MethodOptimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis
Csongrádi, A., Enyedi, A., Takács, I., Végh, T., Mányiné, I. S., Pólik, Z., Altorjay, I. T., Balla, J., Balla, G., Edes, I. F., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0837 · Cited by 21
Duncan, A., Gail, R., Morag, B., & Raja, K. B. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117397 · Cited by 21
Schroder, T. H., Tan, A., Mattman, A., Sinclair, G. B., Barr, S. I., Vallance, H. D., & Lamers, Y. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1337 · Cited by 18
“While reference limits are the generally accepted and recommended clinical approach [24, 48], change point analysis has also been established to develop cut-offs [25].”
BackgroundUnraveling the connection: Inflammatory markers and diabetes mellitus pathogenesis
Obeagu, E. I. (2026) · Medicine · doi:10.1097/md.0000000000047338 · Cited by 28
Krintus, M., Koziński, M., Fabiszak, T., Kubica, J., Panteghini, M., & Sypniewska, G. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.015 · Cited by 17
Building up a clinical microbiota profiling: a quality framework proposal
Scherz, V., Greub, G., & Bertelli, C. (2021) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2021.1975642 · Cited by 19
“In reality, these reference values should be determined by dedicated studies evaluating metric distribution, as recommended for molecular assays in microbiology (Burd 2010) or clinical chemistry (Henny et al. 2016).”
BackgroundPolten, F., Reboll, M. R., Widera, C., Kempf, T., Bethmann, K., Gupta, P., Miglietta, J. J., Pekcec, A., Tillmanns, J., Bauersachs, J. K., et al. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03041 · Cited by 15
Hematological reference intervals for adult population of Dire Dawa town, East Ethiopia
Sissay, T. M., Tibebu, M., Wasihun, T., & Tsegaye, A. (2021) · PLoS ONE · doi:10.1371/journal.pone.0244314 · Cited by 19
“In order to nurture and accommodate the developing foetus, pregnancy is characterized by many physiological and hematological changes, which may appear to be pathological in the non-pregnant state [6, 7].”
BackgroundMixture density networks for the indirect estimation of reference intervals
Hepp, T., Zierk, J., Rauh, M., Metzler, M., & Seitz, S. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04846-0 · Cited by 15
“As a consequence, they may be considered as the most promising approach for this purpose [4], but the conduction of the required prospective studies involves considerable effort and expense.”
BackgroundBianchi, L., Campi, B., Sessa, M. R., Marco, G. D., Ferrarini, E., Zucchi, R., Marcocci, C., Vitti, P., Manetti, L., Saba, A., et al. (2019) · Journal of Endocrinological Investigation · doi:10.1007/s40618-019-01050-5 · Cited by 16
Langlois, M. R., Nordestgaard, B. G., Langsted, A., Chapman, M. J., Aakre, K. M., Baum, H. H. E., Borén, J., Bruckert, É., Catapano, A. L., Cobbaert, C. M., et al. (2021) · Laboratory Service · doi:10.17116/labs20211001145 · Cited by 13
Kontovazainitis, C.-G., Gialamprinou, D., Theodoridis, T., & Mitsiakos, G. (2024) · Diagnostics · doi:10.3390/diagnostics14030347 · Cited by 20
“The main limitations of the above studies concern the sample size, of which some (three out of eight) are small (below 120 participants per group) [102,115,118] for establishing reverence values [122].”
BackgroundPaffoni, A., Somigliana, E., Boeri, L., & Viganò, P. (2022) · Human Reproduction · doi:10.1093/humrep/deac161 · Cited by 17
Qiu, J., Zhou, F., Li, X., Zhang, S., Chen, Z., Xu, Z., Lu, G., Zhu, Z. Y., Ding, N., Lou, J., et al. (2020) · Cancer Management and Research · doi:10.2147/cmar.s221586 · Cited by 12
“Reference intervals were calculated based on the recommendations of the International Federation of Clinical Chemistry (IFCC).(36) The Kolmogorov Simonov test was”
MethodA multicenter reference interval study of thromboelastography in the Chinese adult population
Zeng, X., Fang, L., Peng, Y., Zhang, Y., Li, X., Wang, Z., Zhang, B., Cao, Q., & Hu, X. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.07.019 · Cited by 12
Ghazizadeh, H., Bohn, M. K., Esmaily, H., Boskabadi, M., Mohammadi‐Bajgiran, M., Farahani, E., Boshtam, M., Mohammadifard, N., Sarrafzadegan, N., Adeli, K., et al. (2023) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2023.04.001 · Cited by 13
Favresse, J., Bastin, P., Fillée, C., Luyckx, F., Maiter, D. M., & Gruson, D. (2017) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2016.022632 · Cited by 11
Applications of machine learning in the chemical pathology laboratory
Punchoo, R., Bhoora, S., & Pillay, N. (2021) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2021-207393 · Cited by 11
“75 Use of outpatient data in healthy or low disease prevalence populations can function as reservoirs of big data to establish reference ranges.”
BackgroundHepp, T., Zierk, J., Rauh, M., Metzler, M., & Mayr, A. J. (2020) · BMC Bioinformatics · doi:10.1186/s12859-020-03853-3 · Cited by 11
Call for Standardization of C-Peptide Measurement
Schleicher, E. D., Kabytaev, K., Nauck, M., Müller‐Wieland, D., Peter, A., Little, R. R., & Heinemann, L. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251362848 · Cited by 14
“50 While laboratory verification may still be necessary, a smaller sample size of just 20 participants is sufficient.”
Serum amyloid A in healthy subjects: assessment of reference value using ELISA method
Carbone, T., Pafundi, V., Schievano, C., Assunta, D., Padula, M. C., Giordano, M., Canora, G., Lazzari, C., Padula, A. A., & D’Angelo, S. (2020) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2020.1837160 · Cited by 11
Wu, L., Mai, L., Wang, H., Huang, J., He, X., Zhan, X., Khalemsky, A., Kumar, V. A., Paxton, J. H., Tsilimingras, D., et al. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02522-8 · Cited by 8
Deciphering reference intervals and clinical decision limits in equine endocrine diagnostic testing
Ireland, J. L., & McGowan, C. M. (2023) · The Veterinary Journal · doi:10.1016/j.tvjl.2023.106037 · Cited by 8
Strandberg, J., Gade, I. L., Nybo, J., Thomsen, J. L., & Kristensen, S. R. (2025) · Thrombosis Journal · doi:10.1186/s12959-025-00713-z · Cited by 8
“We planned to include 60–80 participants, which we anticipated to be a possible achievement, slightly less than the 120 participants prescribed by guidelines [31, 32], but giving a reasonable estimate.”
van Duijl, T. T., Ruhaak, L. R., Hoogeveen, E. K., de Mutsert, R., Rosendaal, F. R., le Cessie, S., de Fijter, J. W., & Cobbaert, C. M. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632221121780 · Cited by 7
“The transferability of reference intervals among laboratories remains challenging due to differences in analytical methodologies and reporting units, lack of common calibrators and test standardization and use of different study populations.(20) Kidney injury biomarker concentrations are typically determined by in-hou…”
BackgroundDorji, K., ChhodenR, S., Wangchuk, K., Zangpo, S., Tenzin, S., Dawa, C., Samal, P. D., Nima, Tshering, J., Wangmo, C., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273778 · Cited by 8
“The concept of the RIs was introduced in 1969 and its establishment processes were refined over the period [7, 8].”
BackgroundMa, C., Hou, L., Zou, Y., Ma, X., Wang, D., Hu, Y., Song, A., Cheng, X., & Qiu, L. (2022) · BMC Medical Research Methodology · doi:10.1186/s12874-022-01751-1 · Cited by 6
“[6], we aimed at developing a method for estimating sample sizes for establishment of RIs.”
MethodAgretti, P., Pelosini, C., Bianchi, L., Grosso, A. D., Saba, A., Canale, D., & Sessa, M. R. (2020) · Journal of Endocrinological Investigation · doi:10.1007/s40618-020-01304-7 · Cited by 6
“1a, b) according to the guidelines of document CLSI C28-A3 [12].”
MethodInfluentialArtificial Intelligence in Laboratory Medicine
Brinati, D., Ronzio, L., Cabitza, F., & Banfi, G. (2022) · Springer eBooks · doi:10.1007/978-3-030-64573-1_312 · Cited by 7
Lantman, M. V. S., van Berkel, M., Kuijper, P. H. M., Langelaan, M. L. P., Brouwer, N., & Thelen, M. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae129 · Cited by 5
Self-citationTran, C., Topliss, D. J., Schneider, H. G., Seeman, E., Clayton‐Chubb, D., Neumann, F., Kakoly, N. S., Zhou, Z., Hussain, S. M., Rickard, A. J., et al. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0848 · Cited by 7
“The framework used for establishing a RI was based on the updated guidelines of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine, summarised by Henny et al. [17].”
Naous, E., Hijazi, R., Chalhoub, M., Ghorayeb, N. E., & Gannagé‐Yared, M. (2025) · Heliyon · doi:10.1016/j.heliyon.2025.e42453 · Cited by 5
“The RIs are established by considering the 2.5th and 97.5th percentiles of the values obtained in a reference population [4].”
Halim, S. A., Bahar, R., Abdullah, W. Z., Zon, E. M., & Yusoff, S. M. (2023) · Oman Medical Journal · doi:10.5001/omj.2023.86 · Cited by 5
Principles of methods for indirect determination of reference intervals
Plekhanova, O. S., Цвиренко, С. В., Kalacheva, O. S., & Иосифович, С. Л. (2022) · Laboratory Service · doi:10.17116/labs20221102127 · Cited by 4
Reference intervals of biochemical parameters in Chilean adults
Letelier, P. J., Acuña, R., Garrido, I., López, J., Sanhueza, G., Seguel, C., Riquelme, I., Guzmán, N. H., & Hernández, A. (2023) · Journal of Medical Biochemistry · doi:10.5937/jomb0-44156 · Cited by 6
“…by its reference value (reference intervals; RI), which is a range of values of a measured quantity (measurand), which were obtained from a group of reference individuals that have certain specific characteristics and that are commonly defined within the status of "healthy" individuals (5).”
BackgroundLykkeboe, S., Andersen, S. L., Nielsen, C. G., Vestergaard, P., & Christensen, P. A. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0987 · Cited by 4
Blatter, T. U., Witte, H., Fasquelle-Lopez, J., Nakas, C. T., Raisaro, J. L., & Leichtle, A. B. (2023) · Journal of Medical Internet Research · doi:10.2196/47254 · Cited by 7
“The gold standard for inferring the RI has long been direct methodology , where test results are sampled from a homogeneous and presumably healthy reference population, and the 2.5th and 97.5th percentiles of the obtained sample are determined [49].”
BackgroundBiljak, V. R., Vidranski, V., Ružić, L., Šimundić, A.-M., & Vidranski, T. (2020) · Biochemia Medica · doi:10.11613/bm.2021.010702 · Cited by 6
“A revision of available RIs is a must, taking into account exercise as a very significant covariate (30).”
BackgroundIndirect methods for the verification of reference intervals in laboratory medicine
HOFFMANN, G. E., Trulson, I., Adler, J., Klawitter, S., Holdenrieder, S., & Klawonn, F. (2026) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2026.2687513 · Cited by 3
Ilardo, C., Coulon, G., Ehrhard, Y., & Barthes, J. (2023) · International Journal of Clinical Biochemistry and Research · doi:10.18231/j.ijcbr.2023.024 · Cited by 3
Rigo-Bonnin, R. F., Aliart-Fernández, I., Escalante-Vilanova, A., Brunet, M., Parra‐Robert, M., & Morales‐Ruiz, M. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119822 · Cited by 3
Biochemical, Cellular, and Proteomic Characterization of Hereditary Spherocytosis Among Tunisians
Trabelsi, N., Bouguerra, G., Haddad, F., Ouederni, M., Darragi, I., Boudrigua, I., Chaouachi, D., Mbarka, B., Fouzai, C., Béjaoui, M., et al. (2021) · Cellular Physiology and Biochemistry · doi:10.33594/000000333 · Cited by 3
Biljak, V. R., Đuras, A., Čičak, H., Vidranski, V., Vidranski, T., Peersman, N., Vermeersch, P., Ostroški, I., Ružić, L., & Šimundić, A.-M. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.06.006 · Cited by 3
Hidden metabolic disorders in high-class athletes
Grishina, Z. V., Makarova, G. A., Bazanovich, S. A., Михайловна, Ч. С., Yadgarov, M. Y., Feshchenko, V. S., Pavlova, A. A., Anisimov, E. A., Yashin, T. A., & Zholinskij, A. V. (2021) · Sports medicine research and practice · doi:10.47529/2223-2524.2020.4.3 · Cited by 3
François, C., Haure, J., Billy, J., & Renault, T. (2020) · Veterinary Clinical Pathology · doi:10.1111/vcp.12853 · Cited by 3
Mohammed, O., Kassaw, M., Befekadu, E., Egzeabher, L. G., Tolcha, Y., Challa, F., Kebede, A., Ashebir, G., Meles, M., Hassen, F., et al. (2024) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.25116 · Cited by 2
Soleimani, R., Khourssaji, M., Aupaix, A., Rodriguez‐Villalobos, H., Scohy, A., & Kabamba‐Mukadi, B. (2021) · Journal of Virological Methods · doi:10.1016/j.jviromet.2021.114129 · Cited by 2
Freire, M. D. C., Dias, P. R. T. P., Souza, T. S., Hirose, C. K., Araújo, P. B., & Neves, M. F. (2024) · Jornal de Pediatria · doi:10.1016/j.jped.2024.03.009 · Cited by 2
Lipid levels in a cohort of healthy Danish schoolchildren ages 5 to 17 years
Greve, J., Mørk, F., Jensen, A., Kaur, S., Madsen, J., Bugge, A., Heidemann, M., Wedderkopp, N., & Johannesen, J. (2024) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2024.2370011 · Cited by 2
“Both RI and CDL can vary according to variables such as age, sex, and ethnicity, and this needs to be taken into account when interpreting the results [1,11].”
Hematological and biochemical reference intervals for adult Croatian Posavac horse
Grden, D., Gotić, J., Šimonji, K., Kučer, N., Mrljak, V., Šmit, I., Crnogaj, M., & Matijatko, V. (2019) · Veterinarski arhiv · doi:10.24099/vet.arhiv.0738 · Cited by 2
“The Posavac horse and the Croatian Coldblood are closely related populations (IVANKOVIĆ et al. (2009). There is strong evidence that Posavac horse, although slightly smaller, is a variant of the Croatian Coldblood and is not a distinct breed (GALOV et al.”
BackgroundTunisian Newborn's Cord Blood: Reference Values of Complete Blood Count and Hemoglobin Fractions
Zitouni, S., Bouatrous, E., Laabidi, O., Boudrigua, I., Chaouachi, D., Saidani, N., Kraiem, I., Ayachi, A., Abbès, S., Mourali, M., et al. (2020) · American Journal of Perinatology · doi:10.1055/s-0040-1722199 · Cited by 2
Mansour, I., Zayat, S. E., Karas, S., & Arafat, A. M. A. (2022) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2022.9040 · Cited by 1
“The whole study population both males and females included 1099 subjects with the age range of 1-month to 144 months with a minimum of 120 participants in each preliminary age group/subclass, to achieve the 95% confidence limits stated by the Clinical and Laboratory Standards Institute (CLSI) guidelines [10].”
MethodDoucoure, M., Zéguimé, A., Niangaly, A., Guindo, M. A., Doritchamou, J., Assadou, M. H., Katilé, A., Kanoute, M. B., Perou, S., Ouattara, A., et al. (2024) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.23-0719 · Cited by 2
Reference intervals for serum cystatin C in Brazilian children aged 5–11 years: A short report
Jacobi, N. F., Ciceri, A., de Oliveira, L. R., Tioda, I., Kaefer, M., Oliveira, S. B., Pasqualoto, L., Rossato, B., Moresco, R., Paniz, C., et al. (2025) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632251403403 · Cited by 1
Yamada, S., Horiguchi, K., Akuzawa, M., Sakamaki, K., Yamada, E., Andou, T., & Yamada, M. (2026) · Journal of the Endocrine Society · doi:10.1210/jendso/bvag053 · Cited by 1
“…healthy individuals, and the middle 95% levels (levels within 1.96 standard deviations of the mean) have typically been used, as the middle 95% of a well-defined and sufficiently large disease-free population is likely to provide the most appropriate balance between true and false diagnoses [7, 8].”
InfluentialSuleimenov, Y., Assemov, A., Rsaldina, D., Baikatov, A., Omarova, A., & Bespalko, A. (2026) · Diagnostics · doi:10.3390/diagnostics16172766 · Cited by 1
Lefrère, B., Servonnet, A., Ceppa, F., Dorandeu, F., & Delacour, H. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0207 · Cited by 1
“in an adult population according to the IFFC guidelines [7, 8].”
MethodMartínez-Sánchez, L. M., Marqués-García, F., Özarda, Y., Blanco, A., Brouwer, N., Canalías, F., Cobbaert, C. M., Thelen, M., & den Elzen, W. P. J. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0084 · Cited by 1
Self-citationMilczak, A., Abramowicz, B., SZCZEPANIK, M. P., Madany, J., Wrześniewska, K., Buczek, K., STANIEC, M., Żółkiewski, P., & Kurek, Ł. (2023) · Agriculture · doi:10.3390/agriculture13061224 · Cited by 1
“Choosing the right population is not a simple task as the standard definition of “good health” is particularly difficult to establish [32,33].”
BackgroundMethodPlekhanova, O. S., Цвиренко, С. В., Kalacheva, O. S., & Иосифович, С. Л. (2023) · Laboratory Service · doi:10.17116/labs20231202133 · Cited by 1
Leonard, A., Bolger, T., Molloy, E. J., & Boran, G. P. (2023) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632231202330 · Cited by 1
Hepatoprotective Effect of Quercetin on Oxidative Stress Via TRX-1 in Metabolic Syndrome Male Rats
Bilginoğlu, A. (2019) · International Archives of Endocrinology Clinical Research · doi:10.23937/2572-407x.1510015 · Cited by 1
CME-Labor 53/Auflösung : Postanalytik
von Eckardstein, A. (2018) · PubMed · doi:10.1024/1661-8157/a002923
Reference values of plasma homocysteine in Cuban children and adults
Álvarez, A. C., Viera, I. C., Buigues, L. V., Martínez, Y. F., Hernández, E., Padrón, L. C. M., Rodríguez, J. P., & Giselle, G. T. (2020) · Journal of Laboratory Medicine · doi:10.1515/labmed-2019-0195 · Cited by 1
“RIs vary depending on the biological sample, specific factors affecting the population under analysis and the laboratory analytical methods [9].”
BackgroundIlardo, C. (2021) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2021.86548
Karpuzoglu, H. F. (2023) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2023.86580
Göttgens, E., Haverkate, L., Langelaan, M. L. P., Lunshof, S., Joosen, A. M. C. P., van Gammeren, A. J., Remijn, J. A., Ermens, A. A. M., & Jacobs, L. H. J. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117748
Chen, L., Wang, W., Wang, L., Wang, N., Dong, S., Ding, Y., Chen, G.-Z., Jiang, H., Yu, X., & Sun, C. (2023) · Journal of Laboratory Medicine · doi:10.1515/labmed-2022-0173
Reference interval of optimal vitamin D level for an adult population of BangladeshPreprint
Haque, W. M. M. U., Haq, J. A., Pathan, M. F., & Sayeed, M. A. (2024) · medRxiv · doi:10.1101/2024.11.07.24316898
Freire, M. D. C., Dias, P. R. T. P., Arcuri, L. J., Souza, T. S., Hirose, C. K., Araújo, P. B., & Neves, M. F. (2024) · Research Square · doi:10.21203/rs.3.rs-5334671/v1
Кочнева, А. А., Rabinovich, A. L., Lajus, D., Kurpe, S., & Sukhovskaya, I. (2024) · Proceedings of the Zoological Institute RAS · doi:10.31610/trudyzin/2024.328.4.707
Letelier, P. J., Chicahual, C. A., Arroyo, N. F., Monsalves, D. P., Boguen, R. E., & Guzmán, N. H. (2025) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2024-0080
“RI for clinical laboratory tests are generally not studied in di ff erent subpopulations, nor are they based on speci fi c epidemiological or clinical pro fi les, which is a drawback for the interpretation of laboratory tests [2, 3].”
InfluentialLetelier, P. J., Chicahual, C. A., Arroyo, N. F., Monsalves, D. P., Boguen, R. E., & Guzmán, N. H. (2025) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2025-0014
“Los valores de referencia se obtuvieron aplicando el método no paramétrico del intervalo interpercentil recomendado por la IFCC [2] y el Instituto de Normas Clínicas y de Labo-ratorio ( Clinical and Laboratory Standards Institute , CLSI).”
Influential
Metadata
- Authors
- Henny, J., Vassault, A., Boursier, G., Vukasovic, I., Mesko Brguljan, P., Lohmander, M., Ghita, I., Andreu, F. A. B., Kroupis, C., Sprongl, L., Thelen, M. H. M., Vanstapel, F. J. L. A., Vodnik, T., Huisman, W., & Vaubourdolle, M.
- Affiliations
- Inserm (FR)
- Executive manager, Asqualab, Paris, France
- Université de Montpellier (FR)
- University Department of Chemistry, Sestre Milosrdnice University Hospital Center, Zagreb Croatia
- Department of Clinical Chemistry, University Clinic for Respiratory and allergic Diseases Golnik, Golnik, Slovenia
- NU Hospital Group (SE)
- Synevo Central Lab Clinical trials, Iflov County, Romania
- Servicio de Analisis Clinicos, H.U. Principe de Asturias, Alcalá de Henares, Spain
- Department of Clinical Biochemistry, Attikon University General Hospital, University of Athens Medical School, Greece
- Central Laboratory, Sumperk Hospital a.s., Sumperk, Czech Republic
- Amphia Ziekenhuis (NL)
- Universitair Ziekenhuis Leuven (BE)
- Univerzitetski Klinički Centar Srbije (RS)
- Consultant European Specialist in Clinical Chemistry and Laboratory Medicine, The Hague, The Netherlands
- Assistance Publique – Hôpitaux de Paris (FR)
- Corresponding author
- Vaubourdolle, Michel
- ORCID
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-10-14
- Volume
- 54
- Issue
- 12
- Pages
- 1893-1900
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2530488227
- Cited by
- 119
- References
- 18
- Citations by year
- 2026: 14 · 2025: 13 · 2024: 15 · 2023: 13 · 2022: 10 · 2021: 11 · 2020: 17 · 2019: 11 · 2018: 6 · 2017: 9
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- reference limits, decision limits, reference population selection, analytical quality, terminology, CLSI guidelines, medical laboratories
- MeSH terms
- Chemistry, Clinical, Humans, Laboratories, Reference Standards, Clinical Laboratory Services
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.