CoChat

Falsely elevated plasma testosterone concentrations in neonates: importance of LC-MS/MS measurements

Hamer, Henrike M., Finken, Martijn J.J., van Herwaarden, Antonius E., du Toit, Therina, Swart, Amanda C., Heijboer, Annemieke C. · 2018 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 21

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2017-1028

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 7

  1. Ahmed SF, Achermann JC, Arlt W, Balen A, Conway G, Edwards Z, et al. Society for Endocrinology UK guidance on the initial evaluation of an infant or an adolescent with a suspected disorder of sex development (Revised 2015). Clin Endocrinol (Oxf) 2016;84:771–88. · DOI · Paper page
  2. Fuqua JS, Sher ES, Migeon CJ, Berkovitz GD. Assay of plasma testosterone during the first six months of life: importance of chromatographic purification of steroids. Clin Chem 1995; 41:1146–9. · DOI
  3. Tomlinson C, Macintyre H, Dorrian CA, Ahmed SF, Wallace AM. Testosterone measurements in early infancy. Arch Dis Child Fetal Neonatal Ed 2004;89:F558–9. · DOI
  4. Bui HN, Sluss PM, Blincko S, Knol DL, Blankenstein MA, Heijboer AC. Dynamics of serum testosterone during the menstrual cycle evaluated by daily measurements with an ID-LC-MS/MS method and a 2nd generation automated immunoassay. Steroids 2013;78:96–101. · DOI
  5. Owen WE, Rawlins ML, Roberts WL. Selected performance characteristics of the Roche Elecsys testosterone II assay on the Modular analytics E 170 analyzer. Clin Chim Acta 2010;411:1073–9. · DOI
  6. Winter JS, Hughes IA, Reyes FI, Faiman C. Pituitary-gonadal relations in infancy: 2. Patterns of serum gonadal steroid concentrations in man from birth to two years of age. J Clin Endocrinol Metab 1976;42:679–86. · DOI · Paper page
  7. Forest MG, Sizonenko PC, Cathiard AM, Bertrand J. Hypophyso-gonadal function in humans during the first year of life. 1. Evidence for testicular activity in early infancy. J Clin Invest 1974;53:819–28. · DOI · Paper page

Cited by

Metadata

Authors
Hamer, H. M., Finken, M. J. J., van Herwaarden, A. E., du Toit, T., Swart, A. C., & Heijboer, A. C.
Affiliations
  • Department of Clinical Chemistry , VU University Medical Center , Amsterdam , The Netherlands
  • Department of Pediatric Endocrinology, VU University Medical Center , Amsterdam , The Netherlands
  • Department of Laboratory Medicine, Radboud University Medical Center, Geert Grooteplein 10 , 6525 GA Nijmegen , The Netherlands
  • Department of Biochemistry , Stellenbosch University , Stellenbosch , South Africa
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2018-01-08
Volume
56
Issue
6
Pages
e141-e143
ISSN
  • 1437-4331
  • 1434-6621
Cited by
21
References
3
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.