Biological variation estimates of thyroid related measurands - meta-analysis of bivac compliant studies
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Abstract Objectives Testing for thyroid disease constitutes a high proportion of the workloads of clinical laboratories worldwide. The setting of analytical performance specifications (APS) for testing methods and aiding clinical interpretation of test results requires biological variation (BV) data. A critical review of published BV studies of thyroid disease related measurands has therefore been undertaken and meta-analysis applied to deliver robust BV estimates. Methods A systematic literature search was conducted for BV studies of thyroid related analytes. BV data from studies compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) were subjected to meta-analysis. Global estimates of within subject variation (CV I ) enabled determination of APS (imprecision and bias), indices of individuality, and indicative estimates of reference change values. Results The systematic review identified 17 relevant BV studies. Only one study (EuBIVAS) achieved a BIVAC grade of A. Methodological and statistical issues were the reason for B and C scores. The meta-analysis derived CV I generally delivered lower APS for imprecision than the mean CV A of the studies included in this systematic review. Conclusions Systematic review and meta-analysis of studies of BV of thyroid disease biomarkers have enabled delivery of well characterized estimates of BV for some, but not all measurands. The newly derived APS for imprecision for both free thyroxine and triiodothyronine may be considered challenging. The high degree of individuality identified for thyroid related measurands reinforces the importance of RCVs. Generation of BV data applicable to multiple scenarios may require definition using “big data” instead of the demanding experimental approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“similar findings were reported in a meta-analysis of BV in thyroid-related measures (32).”
From Biological variation in serum thyroid, iron metabolism, and plasma bone metabolism biomarkers in patients with type 2 diabetes mellitus (2025) · cites this paper as [32]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
American Thyroid Association Guidelines for Detection of Thyroid Dysfunction
Ladenson, P. W., Singer, P. A., Ain, K. B., Bagchi, N., Bigos, S. T., Levy, E. G., Smith, S. A., & Daniels, G. H. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.11.1573 · Cited by 575
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Self-citationMaes, M., Mommen, K., Hendrickx, D., Peeters, D., D’Hondt, P., Ranjan, R., De Meyer, F., & Scharpe, S. (1997) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1997.1881002.x · Cited by 231
Ceriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0091 · Cited by 181
Self-citationRøraas, T., Støve, B., Petersen, P. H., & Sandberg, S. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.252296 · Cited by 128
Self-citationCoşkun, A., Sandberg, S., Unsal, I., Cavusoglu, C., Serteser, M., Kilercik, M., & Aarsand, A. K. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvaa233 · Cited by 112
Self-citationEpidemiology of Thyroid Disorders
Vanderpump, M. P. J. (2019) · Springer eBooks · doi:10.1007/978-3-319-72102-6_6 · Cited by 102
Long-term variability in serum thyroglobulin and thyroid related hormones in healthy subjects
Feldt-Rasmussen, U., Petersen, P. H., Blaabjerg, O., & Hørder, M. (1980) · Acta Endocrinologica · doi:10.1530/acta.0.0950328 · Cited by 75
Mahdavi, M., Amouzegar, A., Mehran, L., Madreseh, E., Tohidi, M., & Azizi, F. (2021) · BMC Endocrine Disorders · doi:10.1186/s12902-021-00743-4 · Cited by 71
Research works printed but not linked: 1
- Fraser CG, Sandberg S. Biological variation. In: Rifai N, Horvath AR, Wittwer CT, editors. Tietz textbook of clinical chemistry and molecular biology, 6th ed.; 2017:157-70 pp.
Cited by
Biological variation: recent development and future challenges
Sandberg, S., Carobene, A., Bartlett, W. A., Coşkun, A., Fernández–Calle, P., Jonker, N., Díaz–Garzón, J., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1255 · Cited by 65
Self-citationBias in Laboratory Medicine: The Dark Side of the Moon
Coşkun, A. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2024.44.1.6 · Cited by 50
Coşkun, A., Ertaylan, G., Pusparum, M., Hoof, R. V., Kaya, Z. Z., Khosravi, A., & Zarrabi, A. (2024) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2024.167339 · Cited by 34
Coşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 16
Biological variation – eight years after the 1st Strategic Conference of EFLM
Sandberg, S., Carobene, A., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0086 · Cited by 15
Self-citationConventional and Emerging Diagnostic Approaches for Differentiated Thyroid Carcinoma
Kristollari, K., Paul, A. A., Angel, S., & Marks, R. S. (2024) · Chemosensors · doi:10.3390/chemosensors12110229 · Cited by 11
Short-term biological variation of serum tryptase
Madsen, A. T., Kristiansen, H. P., & Winther‐Larsen, A. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0606 · Cited by 8
Biological variation estimates obtained from Chinese subjects for 32 biochemical measurands in serum
Ma, L., Zhang, B., Luo, L., Shi, R., Wu, Y., & Liu, Y. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0928 · Cited by 5
Özkanay, H., Arslan, F. D., Narin, F., & Köseoğlu, M. (2023) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2023.2278537 · Cited by 4
Zhou, X. J., Liu, Z., Ma, Y., Zhang, C., & Wu, Y. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117513 · Cited by 4
Interpretation of TSH results can be improved by reference values fluctuating in time
Delanghe, J., Elslande, J. V., Godefroid, M., Speeckaert, M. M., & Maenhout, T. M. (2024) · Hormone Molecular Biology and Clinical Investigation · doi:10.1515/hmbci-2024-0043 · Cited by 5
Brochier, A., Mairesse, A., Saussoy, P., Gavard, C., Desmet, S., Hermans, C. R. J. R., Gruson, D., & van Dievoet, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0377 · Cited by 6
Marqués-García, F., Librero, A. B. N., Tejedor-Ganduxé, X., & Martinez-Bravo, C. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2464244 · Cited by 3
Hormonal and other methods of thyroid gland examination: A literature review
Soyka, L., Kovalchuk, O. I., & Upatova, I. (2024) · Bulletin Of Medical And Biological Research · doi:10.61751/bmbr/2.2024.85 · Cited by 3
Interpreting two TSH results from the same patient
Åsberg, A., & Mikkelsen, G. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0478 · Cited by 3
Özkanay, H., Arslan, F. D., Köseoğlu, M., & Yıldız, R. (2025) · Biochemia medica · doi:10.11613/bm.2025.010706 · Cited by 2
“The BV is also important for defining analytical performance specifications (APS) (imprecision and bias) (5).”
Bildirici, M. A., Aliyazıcıoğlu, Y., Yaman, H., Karahan, S. C., & Örem, A. (2025) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2024-0200 · Cited by 3
On the importance of sampling interval in studies of biological variation in thyroid function
Andersen, S., Riis, J., Karmisholt, J., & Andersen, S. L. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1130 · Cited by 2
Choi, R., Chun, G., Go, U. Y., Lee, S. G., & Lee, E. H. (2022) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24319 · Cited by 3
Biological variation of serum neopterin concentrations in apparently healthy individuals
Dülgeroğlu, Y., & Ercan, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1030 · Cited by 1
Moreno-Parro, I., Díaz-Garzón, J. J., Sufrate-Vergara, B., Aarsand, A. K., Sandberg, S., Carobene, A., Itkonen, O., Bartlett, W. A., Coşkun, A., Jonker, N., et al. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.120985 · Cited by 1
Self-citationZhou, C.-Q., Xie, Q., Wang, H., Wu, F., He, D.-H., Huang, Y., He, Y., Dai, S., Chen, J., Kong, L.-R., et al. (2024) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-024-03621-9 · Cited by 2
“The individuality index (II) and reference change value (RCV), and positive (upward) and negative (downward) RCV (RCVpos, RCVneg) were calculated as follows [27–29]: where the bilateral value of Z is 1.96 under 95% probability.”
InfluentialGuillaume, L., Chapelle, V., Deltombe, M., Nevraumont, A., Mairesse, A., Maisin, D., & Gruson, D. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0966 · Cited by 2
Wang, X., Zhang, M., Liu, Z., Li, C., Li, Y., Huang, H., He, H., & Yu, X. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1506664
Zhou, C.-Q., Xie, Q., Wang, H., Wu, F., He, D.-H., Huang, Y., He, Y., Dai, S., Chen, J., Zhang, Y., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-2502691/v1
Kumari, S. J., Abraham, M. J., & Ayyar, V. S. (2023) · The Journal of Clinical and Scientific Research · doi:10.4103/jcsr.jcsr_11_23
Bokulić, A., Zec, I., Stanišić, L., Šupe‐Domić, D., Pezo, A., Kocijančić, M., Marijančević, D., Kuprešanin, M. S., Goreta, S., Đuras, A., et al. (2025) · Biochemia Medica · doi:10.11613/bm.2025.030505 · Cited by 1
“Although the World Health Organization (WHO) recommended serum samples, the difference in TSH concentrations be-tween serum and plasma tubes had no clinical significance and was in accordance with desirable specifications for bias (30).”
KAZAR, M., Akşit, M., Çolak, A., & Topçu, D. İ. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121220
Çubukçu, H. C., Carobene, A., Aarsand, A. K., Sandberg, S., & Coşkun, A. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0863 · Cited by 1
“…full compliance with BIVAC, are scarce; as shown by systematic reviews published by the EFLM Technical Committee Biological Variation Database for hematological parameters [31], glycemic markers [32], measurands related to kidney function [33], thyroid hormones [34], and tumor markers [35].”
Self-citationBulut, T. S. D., & Yılmaz, G. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121281
Metadata
- Authors
- Fernández-Calle, P., Díaz-Garzón, J., Bartlett, W., Sandberg, S., Braga, F., Beatriz, B., Carobene, A., Coskun, A., Gonzalez-Lao, E., Marques, F., Perich, C., Simon, M., & Aarsand, A. K.
- Affiliations
- Analytical Quality Commission, Spanish Society of Laboratory Medicine (SEQCML) , Barcelona , Spain
- University of Dundee (GB)
- Haukeland University Hospital (NO)
- University of Milan (IT)
- IRCCS Ospedale San Raffaele (IT)
- Department of Medical Biochemistry Atasehir , School of Medicine, Acibadem Mehmet Ali Aydınlar University , Istanbul , Turkey
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2021-11-15
- Volume
- 60
- Issue
- 4
- Pages
- 483-493
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W3213121456
- Cited by
- 31
- References
- 32
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 5 · 2023: 11 · 2022: 5
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Discovery Research Portal (University of Dundee) (publishedVersion, other-oa)
- Acibadem University Open Access Repository (submittedVersion)
- Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, analytical performance specifications, within-person variability, reference change value, free thyroxine, triiodothyronine, individuality, thyroid function tests
- MeSH terms
- Hematologic Tests, Humans, Reference Values, Thyroid Gland, Biomarkers, Checklist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.