Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 50 references it cites were found in a registry or an index.

Diagnostic performance of machine learning models using cell population data for the detection of sepsis: a comparative study

Aguirre, Urko, Urrechaga, Eloísa · 2023 · Clinical Chemistry and Laboratory Medicine (CCLM)

Abstract

Objectives: To compare the artificial intelligence algorithms as powerful machine learning methods for evaluating patients with suspected sepsis using data from routinely available blood tests performed on arrival at the hospital. Results were compared with those obtained from the classical logistic regression method. Methods: The study group consisted of consecutive patients with fever and suspected infection admitted to the Emergency Department. The complete blood counts (CBC) were acquired using the Mindray BC-6800 Plus analyser (Mindray Diagnostics, Shenzhen, China). Cell Population Data (CPD) were also recorded. The ML and artificial intelligence (AI) models were developed; their performance was evaluated using several indicators, such as the area under the receiver operating curve (AUC), calibration plots and decision curve analysis (DCA). Results: Overall, all the tested approaches obtained an AUC>0.90. The logistic regression (LR) performed well compared to the ML/AI models. The naïve Bayes and the K-nearest neighbour (KNN) methods did not show good calibration properties. The multi-layer perceptron (MLP) model was the best in terms of discrimination, calibration and clinical usefulness. Conclusions: The best performance in the early detection of sepsis was achieved using the ML and AI models. However, external validation studies are needed to strengthen model derivation and procedure updating.

Overview

Integrity signals

Registry

Crossref · 10.1515/cclm-2022-0713

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

1 retracted

Show all 50 references

Research works printed but not linked: 2

  1. Kohavi, R. A study of cross-validation and bootstrap for accuracy estimation and model selection. In: International joint conference on artificial intelligence IJCA; 1995, vol. 2:9 p.
  2. Hoffmann, J. New hematology analyzer parameters and their clinical relevance. EFLM Newslett 2018;1:3.

Cited by

See all 17

Metadata

Authors
Aguirre, U., & Urrechaga, E.
Affiliations
  • Osasun Sistemen Ikerketa Institutua (ES)
  • BioCruces Health research Institute (ES)
Corresponding author
Aguirre, Urko
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2022-11-11
Volume
61
Issue
2
Pages
356-365
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W4308632660
Cited by
17
References
50
Citations by year
2026: 1 · 2025: 7 · 2024: 5 · 2023: 4
FWCI
2.89
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
  • Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
sepsis detection, cell population data, complete blood count, machine learning, artificial intelligence, multilayer perceptron, logistic regression, naive Bayes, k-nearest neighbors, emergency department, early diagnosis, model calibration, decision curve analysis
MeSH terms
Machine Learning, Artificial Intelligence, Bayes Theorem, Humans, Logistic Models, Sepsis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic performance of machine learning models using cell population data for the detection of sepsis: a comparative study. https://app.cochat.ai/papers/10.1515/cclm-2022-0713
The paper
Aguirre, U., & Urrechaga, E. (2023). Diagnostic performance of machine learning models using cell population data for the detection of sepsis: a comparative study. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2022-0713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.