Kinetic Determination of Serum Glucose by Use of the Hexokinase/Glucose-6-phosphate Dehydrogenase Method
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a kinetic fixed-time approach for the quantitative determination of serum glucose by use of the hexokinase/glucose-6-phosphate dehydrogenase method. To achieve a large measuring range, we have apparently increased the Michaelis constant of glucose-6-phosphate dehydrogenase through addition of the competitive inhibitor ATP. By this means, serum samples with glucose concentrations up to 55.5 mmol/l could be analyzed without pre-dilution. The method has been adapted to the ENI GEMSAEC analyzer and to the LKB 2086 Mark II analyzer. It yielded satisfactory results with regard to precision. A comparison of the kinetic procedure with the manual end-point method showed good agreement. No interferences from hemoglobin, bilirubin, or lipemia have been observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flint, A., Raben, A., Ersbøll, A., Holst, J., & Astrup, A. (2001) · International Journal of Obesity · doi:10.1038/sj.ijo.0801627 · Cited by 384
Raben, A., Agerholm-Larsen, L., Flint, A., Holst, J. J., & Astrup, A. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.1.91 · Cited by 365
Sloth, B., Krog-Mikkelsen, I., Flint, A., Tetens, I., Björck, I., Vinoy, S., Elmståhl, H., Astrup, A., Lang, V., & Raben, A. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.2.337 · Cited by 273
The use of glycaemic index tables to predict glycaemic index of composite breakfast meals
Flint, A., Møller, B. K., Raben, A., Pedersen, D., Tetens, I., Holst, J. J., & Astrup, A. (2004) · British Journal of Nutrition · doi:10.1079/bjn20041124 · Cited by 202
“Hoffmann-La Roche LTP, Basel, Switzerland) and an ABX Diagnostics Glucose HK 125 kit (Deeg et al. 1980).”
MethodFlint, A., Gregersen, N. T., Gluud, L. L., Møller, B. K., Raben, A., Tetens, I., Verdich, C., & Astrup, A. (2007) · British Journal of Nutrition · doi:10.1017/s000711450768297x · Cited by 192
Metadata
- Authors
- Deeg, R., Kraemer, W., & Ziegenhorn, J.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 1980
- Volume
- 18
- Issue
- 1
- Pages
- 49-52
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2143938980
- Cited by
- 32
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinetic Determination of Serum Glucose by Use of the Hexokinase/Glucose-6-phosphate Dehydrogenase Method. https://app.cochat.ai/papers/10.1515/cclm.1980.18.1.49
- The paper
- Deeg, R., Kraemer, W., & Ziegenhorn, J. (1980). Kinetic Determination of Serum Glucose by Use of the Hexokinase/Glucose-6-phosphate Dehydrogenase Method. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.1980.18.1.49
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.