The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I
Open accessAbstract
Procedures for the statistical evaluation of method comparisons and instrument tests often have a requirement for distributional properties of the experimental data, but this requirement is frequently not met. In our paper we propose a new linear regression procedure with no special assumptions regarding the distribution of the samples and the measurement errors. The result does not depend on the assignment of the methods (instruments) to X and Y. After testing a linear relationship between X and Y confidence limits are given for the slope beta and the intercept alpha; they are used to determine whether there is only a chance difference between beta and 1 and between alpha and 0. The mathematical background is amplified separately in an appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Regression analysis according to Passing and Bablok 30 showed that slopes between the BGMS and the GOD method ranged from 0.85 to 1.08 and from 0.81 to 1.01 when compared with the HK method.”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistical Methods
(1999) · Technometrics · doi:10.1080/00401706.1999.10485954 · Cited by 6,118
Distribution-Free Statistical Tests
Bell, C. B., & Bradley, J. V. (1970) · Technometrics · doi:10.1080/00401706.1970.10488744 · Cited by 1,703
Distribution-Free Statistical Methods.
Hora, S. C., & Maritz, J. S. (1984) · Journal of the American Statistical Association · doi:10.2307/2288300 · Cited by 154
Cumulative Sum Tests: Theory and Practice
Burr, I. W., & de Bruyn, C. S. V. D. (1969) · Technometrics · doi:10.2307/1267036 · Cited by 138
Linear Free Energy Relationships as Tools for Investigating Chemical Similarity—Theory and Practice
Wold, S., & Sjöstróm, M. (1978) · Springer eBooks · doi:10.1007/978-1-4615-8831-3_1 · Cited by 19
Robuste Schätzung im Linearen Modell
Heiler, S. (1980) · Medizinische Informatik und Statistik · doi:10.1007/978-3-642-81511-9_4 · Cited by 3
Praktische Erfahrung mit R-robusten Verfahren bei klinischen Versuchen
Wolf, G. K. (1980) · Medizinische Informatik und Statistik · doi:10.1007/978-3-642-81511-9_7 · Cited by 2
Research works printed but not linked: 3
- Bablok, 1983, is obtained No Passing and ncw procedure for testing the cquality of mcasurements from two methods If we substitute the structural relationship in the de - finition of the S - we find y t - y t - - From yf ßx and djj we get o ß djj - - dij, Clin Chem Clin Biochem, 21
- Bablok, 1983, Clearly the new procedure takes into account the experimental reality of method comparisons s de - scribed in chapter No Passing and new procedure for testing the eq ality of measurements from two methods ϋ er ί - α CD α σ ρ - σ ο χ : i - ο ο : σα ε ο, Clin Chem Clin Biochem, 2, 3
- Bablok, 1983, and Biochern No Passing and new procedure for testing the equality of measurements from two methods It follows that : sup and max l cusum i hY V l, Clin Chern, 0
Cited by
Sorted by citations
Items 901–1,000 of 1,001
Keller, T., Butz, H., Lein, M., KWIATKOWSKI, M. K., Semjonow, A., Luboldt, H., Hammerer, P., Stephan, C., & Jung, K. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.039552 · Cited by 9
Naum, A., Tuunanen, H., Engblom, E., Oikonen, V., Sipilä, H. T., Iozzo, P., Nuutila, P., & Knuuti, J. M. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0259-3 · Cited by 9
Borque, L., Maside, C., & Iglesias, A. (1993) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1993.31.12.869 · Cited by 9
Muthalagu, A., Niculita‐Hirzel, H., Shen, Y., Merizak, M., Pikridas, M., Qureshi, A., Wargocki, P. L., Bekö, G., Williams, J., Täubel, M., et al. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110458 · Cited by 8
Equations for smartphone prediction of adiposity and appendicular lean mass in youth soccer players
Minetto, M. A., Pietrobelli, A., Ferraris, A., Busso, C., Magistrali, M., Vignati, C., Sieglinger, B. A., Bruner, D., Shepherd, J., & Heymsfield, S. B. (2023) · Scientific Reports · doi:10.1038/s41598-023-48055-y · Cited by 8
Severo, D. D. S., Martins, W. F., Miotto, M., Verruck, S., de Oliveira, R. R., & de Aragão, G. M. F. (2024) · Food Microbiology · doi:10.1016/j.fm.2024.104650 · Cited by 9
Capdevila, M., JONG, A. D., Belafia, F., Vonarb, A., Carr, J., Molinari, N., Choquet, O., Capdevila, X., & Jaber, S. (2024) · Anesthesiology · doi:10.1097/aln.0000000000005267 · Cited by 8
Moyo, S. M., Bussmann, H., & Mangwendeza, P. M. (2011) · Journal of Antivirals & Antiretrovirals · doi:10.4172/jaa.1000034 · Cited by 8
Gancz, A. Y., Eshar, D., & Beaufrère, H. (2019) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2017-0110 · Cited by 8
Fuhrmann, M., Santamaría, A. S., Scott, R. J., Meeusen, J. W., Fernandes, M., Venz, J., Rothe, V., Stämmler, F., Ehrich, J. H. H., & Schiffer, E. (2022) · Diagnostics · doi:10.3390/diagnostics12051120 · Cited by 8
Prediction of fat-free mass in young children using bioelectrical impedance spectroscopy
Lyons‐Reid, J., Ward, L. C., Derraik, J. G. B., Tint, M. T., Monnard, C. R., Nieves, J. M. R., Albert, B. B., Kenealy, T. W., Godfrey, K. M., Chan, S., et al. (2023) · European Journal of Clinical Nutrition · doi:10.1038/s41430-023-01317-4 · Cited by 8
Tammam, M. A., Aly, O., Pereira, F., Mahdy, A., & El‐Demerdash, A. (2024) · Current Research in Biotechnology · doi:10.1016/j.crbiot.2024.100175 · Cited by 8
Clinical evaluation of a fully electronic microfluidic white blood cell analyzer
Sui, J., Lin, Z., Azizpour, S., Chen, F., Gaur, S., Keene, K. R., Soleimani, F., Bhowmick, T., Rafique, Z., & Javanmard, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0296344 · Cited by 8
Pradella, M., & Cesana, B. M. (2016) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-016-0110-1 · Cited by 8
Roli, L., Santi, D., Belli, S., Tagliavini, S., Cavalieri, S., Santis, M. C. D., Baraldi, E., Fanelli, F., Mezzullo, M., Granata, A. R. M., et al. (2017) · Journal of Endocrinological Investigation · doi:10.1007/s40618-017-0653-7 · Cited by 8
Introduction of a Novel Smartphone-Coupled Blood Glucose Monitoring System
Jendrike, N. R. M., Baumstark, A., Chen, C.-H., Rittmeyer, D., Haug, C., & Freckmann, G. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817706594 · Cited by 8
Ruys, C. A., van de Lagemaat, M., Lafeber, H. N., Rotteveel, J., & Finken, M. J. J. (2018) · Clinical Endocrinology · doi:10.1111/cen.13733 · Cited by 8
Hörber, S., Lehmann, R., & Peter, A. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13119 · Cited by 8
Glady, L., Lavaux, T., Charchour, R., Lacorte, J., & Lessinger, J. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1145 · Cited by 8
Lucena, D. D., Escaramís, G., Villar‐Piqué, A., Hermann, P., Schmitz, M., Varges, D., Santana, I. J., del Río, J. A., Martí, E., Ferrer, I., et al. (2020) · Journal of Neurology · doi:10.1007/s00415-020-09870-9 · Cited by 8
Rood, J. J. M., Toraño, J. S., Somovilla, V. J., Beijnen, J. H., & Sparidans, R. W. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2021.122554 · Cited by 8
Nia, H. S., Chong, P. P., Chan, Y. H., Görgülü, Ö., Taghipour, B., Froelicher, E. S., Sharif, S. P., & Rahmatpour, P. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.16166 · Cited by 8
Use of a Point-of-Care Progesterone Assay to Predict Onset of Parturition in the Bitch
Nöthling, J. O., Joone, C., Hegarty, E., Schooley, E. K., & Cramer, K. G. M. D. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.914659 · Cited by 10
Sakaguchi, Y., Arima, R., Maeda, R., Obayashi, T., Masuda, A., Funakoshi, M., Tsuchiya, Y., Ichikawa, N., & Inoue, K. (2023) · Analytical Sciences · doi:10.1007/s44211-023-00266-z · Cited by 8
Pieroni, C., Grassi, A., Pantoli, M., Berretti, M., Messina, S., Giovannini, C., Lubas, G., & Diamanti, D. (2023) · Veterinary Medicine International · doi:10.1155/2023/9965095 · Cited by 8
Chiu, R. W. K., Jin, Y., Chung, G. T., Lui, W.-B., Chan, A. T. �., Lim, W. W. L., & Lo, Y. M. D. (2006) · BMC Infectious Diseases · doi:10.1186/1471-2334-6-20 · Cited by 8
Influence of the immunoassay used in measurement of serum vitamin D levels
Pintado, S. G., & Burriel, P. L. E. (2014) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2014.02.012 · Cited by 8
TESTING THE AGREEMENT OF TWO QUANTITATIVE ASSAYS IN INDIVIDUAL MEANS
Zhong, B., & Shao, J. (2002) · Communication in Statistics- Theory and Methods · doi:10.1081/sta-120006069 · Cited by 8
Jovičić, S. Ž., Ignatović, S., Kangrga, R., Beletić, A. D., Mirković, D., & Majkić‐Singh, N. (2012) · Journal of Medical Biochemistry · doi:10.2478/v10011-012-0027-9 · Cited by 8
Simple Method for Correcting Total Protein in Plasma for Actual Fibrinogen Content
Bakker, A. J., Gorgels, J. P. M. C., Draaisma, J. T. M., Jongendijk, M., Altena, L., Hamersma, A., & Weiland, A. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.11.2221 · Cited by 8
Validation of an enzyme-linked immunosorbent assay for measurement of feline haptoglobin
Stiller, J., Jasensky, A., Hennies, M., Einspanier, R., & Kohn, B. (2016) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638716634397 · Cited by 8
A comparison of manual counting of rabbit reticulocytes with ADVIA 2120i analyzer counting
Kaufhold, A. E., Hirschberger, J., Reese, S., Foerster, G., & Hein, J. (2018) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638717750428 · Cited by 8
Knešaurek, K., Tuli, A., Pasik, S. D., Heiba, S., & Kostakoğlu, L. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.10.015 · Cited by 8
Grgurević, I., Salkic, N. N., Božin, T., Mustapić, S., Matic, V., Dumić-Čule, I., Drinković, I. T., & Bokun, T. (2018) · European Radiology · doi:10.1007/s00330-018-5831-2 · Cited by 8
Barboza, T. K., & Beaufrère, H. (2019) · Journal of Avian Medicine and Surgery · doi:10.1647/2017-291 · Cited by 8
Lottig, N. R., Phillips, J. S., Batt, R. D., Scordo, F., Williamson, T. J., Carpenter, S. R., Chandra, S., Hanson, P. C., Solomon, C. T., Vanni, M. J., et al. (2021) · Limnology and Oceanography Methods · doi:10.1002/lom3.10471 · Cited by 8
Fujiwara, M., & Kita, Y. (2012) · Modern Rheumatology · doi:10.1007/s10165-012-0652-7 · Cited by 8
New developments in the standardization of total prostate-specific antigen
BLIJENBERG, B. G., Storm, B., van Zelst, B. D., Kruger, A. E. B., & Schröder, F. H. (1999) · Clinical Biochemistry · doi:10.1016/s0009-9120(99)00074-0 · Cited by 8
A Fully Automated Enzyme Immunoassay for the Measurement of Cortisol in Biological Fluids
Bacarese-Hamilton, T., Cattini, R., Shandley, C., Howard, C., Palmer, R., & McFarthing, K. (1992) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1992.30.9.531 · Cited by 8
CARBOHYDRATE-DEFICIENT TRANSFERRIN IS NOT AFFECTED BY SERUM SEPARATORS
Arndt, T., Czylwik, D., Hackler, R., Helwig-Rolig, A., & Gilg, T. (1998) · Alcohol and Alcoholism · doi:10.1093/alcalc/33.5.447 · Cited by 8
Ben‐Haroush, A., BELKIN, A., Chezar, J., ORLIN, J. B., Hod, M., & Bar, J. (2007) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1080/00016340701415509 · Cited by 8
Lein, M., Jung, K., Schnorr, D., Henke, W., & Loening, S. A. (1996) · PubMed · Cited by 8
Some Analytical Considerations on the Measurement of Prostate-Specific Antigen
BLIJENBERG, B. G., Ries Kranse, C., Eman, I., & Schröder, F. H. (1996) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1996.34.10.817 · Cited by 8
d’Eril, G. V. M., Bosoni, T., Moratti, R., Ventrucci, M., Fumagalli, A., & Tarenghi, G. (1992) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1992.30.7.439 · Cited by 8
Fink, P. C., de Boutemard, C. S., & Haeckel, R. (1989) · PubMed · Cited by 8
Krombholz, S., Thomas, A., Delahaut, P., Bidlingmaier, M., Schilbach, K., Miller, G. D., & Thevis, M. (2023) · Growth Hormone & IGF Research · doi:10.1016/j.ghir.2023.101560 · Cited by 7
A New, Simple Wrist-Mounted PVDF Sensor for Continuous Heart Rate Monitoring
Parlato, S., Esposito, D., Centracchio, J., Andreozzi, E., Gragnaniello, M., Riccio, M., & Bifulco, P. (2024) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas60918.2024.10636484 · Cited by 8
Carter, J. A., Barber, C. A., Wolle, M. M., & Gray, P. J. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-05989-8 · Cited by 8
Weissenbacher, S., Yang, C., Kuan, T.-C., Demircik, F., Hanna, M., & Pfützner, A. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1662300 · Cited by 7
Lyons‐Reid, J., Ward, L. C., Derraik, J. G. B., Tint, M., Monnard, C. R., Nieves, J. M. R., Albert, B. B., Kenealy, T. W., Godfrey, K. M., Chan, S., et al. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.980790 · Cited by 7
Evaluation of current indirect methods for measuring LDL-cholesterol
Drobnik, S., Scharnagl, H., Samani, N. J., Braund, P. S., Nelson, C. P., Hollstein, T., Kassner, U., Dressel, A., Drobnik, W., & März, W. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0024 · Cited by 7
Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL
Calderón, J. L. M., Pérez, J. V., Bustos, F., & Gómez, J. C. S. (2015) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2015.03.006 · Cited by 7
Wiesen, M. H. J., Blaich, C., Taubert, M., Jennissen, V., Streichert, T., Pfister, R., & Michels, G. (2018) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-018-2421-9 · Cited by 7
Automatic analysis of global spinal alignment from simple annotation of vertebral bodies
Doerr, S. A., Silva, T. D., Vijayan, R. C., Han, R., Uneri, A., Ketcha, M. D., Zhang, X., Khanna, N., Westbroek, E. M., Jiang, B., et al. (2020) · Journal of medical imaging · doi:10.1117/1.jmi.7.3.035001 · Cited by 7
Stolz, M., Schlawne, C., Hoffmann, J., Hartmann, V., Marini, I., Fritsche, A., Peter, A., Bakchoul, T., & Schick, F. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4358 · Cited by 7
Badawy, E. A., El-Laithy, N. A., Morsy, S., Ashour, M. N., Elias, T. R., Masoud, M. M., & Aly, O. (2020) · Egyptian Journal of Medical Human Genetics · doi:10.1186/s43042-020-00080-6 · Cited by 7
Chen, M., Qin, S., Yang, S., Chen, H., Lu, L., & Qin, X. (2021) · Journal of Medical Biochemistry · doi:10.5937/jomb0-34328 · Cited by 8
Blume, B., Witting, M. A., Schmitt‐Kopplin, P., & Michalke, B. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.788094 · Cited by 7
Brenn‐White, M., Raphael, B. L., Rakotoarisoa, N. A. T., & Deem, S. L. (2022) · PLoS ONE · doi:10.1371/journal.pone.0264111 · Cited by 7
Herdina, A. N., Ratzinger, F., Breuer, M., Schellnegger, J., Chen, R. Q., Watkins‐Riedel, T., Perkmann‐Nagele, N., & Straßl, R. P. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.02157-22 · Cited by 8
Lorubbio, M., Diamanti, D., Ghiandai, A., Pieroni, C., Bonini, D., Pettinari, M., Gorini, G., Bassi, S., Meloni, P., & Ognibene, A. (2024) · Diagnostics · doi:10.3390/diagnostics14050557 · Cited by 7
Validation of a New (1 → 3)-β-D-Glucan Test Kit, Fungitec G Test MKⅡ “ Nissui ”
Obayashi, T., Sugimoto, A., Takigawa, C., Sekiya, N., Nagasawa, J., & Ozaki, Y. (2015) · Medical Mycology Journal · doi:10.3314/mmj.56.j73 · Cited by 7
Influencia del inmunoensayo empleado en la determinación de vitamina D sérica
Pintado, S. G., & Burriel, P. L. E. (2014) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2013.04.015 · Cited by 7
Hepatitis C Virus RNA Quantitation in Venous and Capillary Small-Volume Whole-Blood Samples
Bruns, T., Steinmetzer, K., Ermantraut, E., & Stallmach, A. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.00925-09 · Cited by 7
Simultaneous Determination of Urinary Phosphate and Sulphate by Ion-Chromatography
Claßen, A., Miersch, W. D. E., & Hesse, A. (1990) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1990.28.2.91 · Cited by 7
Minder, E. I., Schneider‐Yin, X., & Minder, C. E. (2010) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-8-60 · Cited by 7
Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations
Ialongo, C., & Bernardini, S. (2017) · Biochemia Medica · doi:10.11613/bm.2017.020 · Cited by 8
Mei, S., Li, X., Gong, X., Zhang, X., Li, X., Yang, L., Zhu, L., Zhou, H., Liu, Y., Zhou, A., et al. (2017) · Biomedical Chromatography · doi:10.1002/bmc.3959 · Cited by 7
Akyıldız, B. N. (2017) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0000000000001038 · Cited by 7
Leung, Y. B., Cave, N., & Hodgson, B. (2018) · New Zealand Veterinary Journal · doi:10.1080/00480169.2018.1492984 · Cited by 7
Performance of 6 routine coagulation assays on the new Roche Cobas t711 analyzer
Oostendorp, M., Noorman, R. L., Nijenhuis, J. D., & de Kok, J. B. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00146 · Cited by 7
Measuring the body temperature: How accurate is the Tempa Dot®?
den Bruel, A. V., Aertgeerts, B., Boeck, C. D., & Buntinx, F. (2005) · Technology and Health Care · doi:10.3233/thc-2005-13203 · Cited by 7
Limited Dynamic Range of a New Assay for Serum Folate
Billen, J., Zaman, Z., Claeys, G., & Blanckaert, N. J. C. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.581 · Cited by 7
Antonaglia, V., Torelli, L., Zin, W. A., & Gullo, A. (2004) · Physiological Measurement · doi:10.1088/0967-3334/26/1/002 · Cited by 7
Vermes, I., & Spooren, P. F. M. J. (1992) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.1860060606 · Cited by 7
Technical evaluation of the Beckman Coulter OV-Monitor (CA 125 antigen) immunoassay
Yagmur, E., Driesch, R., Gressner, A. M., & Kiefer, P. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.083 · Cited by 7
Schulze, A., Schaller, P., Dinger, J., Winkler, U., & Gmyrek, D. (1991) · European Journal of Pediatrics · doi:10.1007/bf02072632 · Cited by 7
Rami, L., Roura, M., & Canalías, F. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.04.004 · Cited by 7
Xia, C., Tong, Q., Wang, Q., Tang, Z.-L., Qi, L., Chi, S., Zhang, M., Wang, X., Li, H., & Xu, G. (2010) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009210 · Cited by 7
Evaluation of the QBC-vet autoread haematology system for domestic and pet animal species
Hofmann‐Lehmann, R., Wegmann, D., Winkler, G. C., & Lutz, H. (1998) · Comparative Clinical Pathology · doi:10.1007/bf02642500 · Cited by 7
Procedure for studying commutability validated by biological variation
Ricós, C., Juvany, R., Jiménez, C. V., Perich, C., Minchinela, J., Hernández, A., Simón, M. S., & Álvarez, V. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(97)00172-1 · Cited by 7
Briggs, C., Machin, S. J., MÜLLER, M., HAASE, W., Hofmann, K. W., FORSTREUTER, F., & Hinzmann, R. (2009) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.01017.x · Cited by 7
Kontis, K. J., Valcour, A., Patel, A., Chen, A., Wang, J., Chow, J., & Nayak, N. (2006) · PubMed · Cited by 7
Mourvaki, E., Ferrante, F., Ghirarduzzi, A., Brini, M., Depunzio, I., & Iorio, A. (2005) · American Journal of Clinical Pathology · doi:10.1309/0f85-mtu8-kl3d-7jjp · Cited by 11
Determination of pancreatic lipase by immunoactivation technology
Uhl, W. H., Malfertheiner, P., Drosdat, H., Martini, M., & Büchier, M. (1992) · International Journal of Pancreatology · doi:10.1007/bf02924365 · Cited by 7
Winkler, G. C., Engeli, E., Rogg, E., Kieffer, J., Kellenberger, H., & Lutz, H. (1995) · Comparative Clinical Pathology · doi:10.1007/bf00638932 · Cited by 7
Schütz, E., Shipkova, M., Niedmann, P. D., Wieland, E., Armstrong, V. W., & Oellerich, M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1269 · Cited by 7
Lee, P., Yu, W., Zhou, J., Tsai, T., Manor, B. D., & Lo, O. (2024) · JMIR mhealth and uhealth · doi:10.2196/52166 · Cited by 6
Fernandez, J. M., Hernández-Socorro, C. R., Robador, L., Rodríguez‐Esparragón, F., Medina-García, D., Quevedo‐Reina, J. C., Lorenzo-Medina, M., Oliva-Dámaso, E., Pérez-Borges, P., & Rodríguez‐Pérez, J. C. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00400-0 · Cited by 6
Park, S. A., An, Y., Park, Y.-J., Lee, J.-Y., Jeon, H., Kim, Y. S., Lee, K., Sun, K., Lee, S. M., & Moon, S. Y. (2025) · Journal of Alzheimer s Disease · doi:10.1177/13872877251314886 · Cited by 6
Nolen‐Walston, R. D., Kulp, J. C., Stefanovski, D., & Eps, A. W. V. (2025) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.70038 · Cited by 6
Li, W., Zhang, J., Liao, J., Zhu, M., Wang, X., Zhou, X., Ma, Z., Hilal, M. E., Chua, S. L., Tan, G., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c00930 · Cited by 6
Specimen Recentrifugation and Elevated Troponin I Levels
Canovi, S., Campioli, D., & Marcheselli, L. (2015) · Laboratory Medicine · doi:10.1309/lmpc95el4pyewwbr · Cited by 6
Arai, Y., Wang, D., Takeuchi, M., Utsunomiya, S., Degawa, T., Kai, A., Ichikawa, H., Chiba, R., & Yoshimura, T. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1227357 · Cited by 6
Braun, V., Ceglarek, U., Gaudl, A., Gawinecka, J., Müller, D., Rauh, M., Weber, M., & Seger, C. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0847 · Cited by 6
Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013
Pleus, S., Baumstark, A., Rittmeyer, D., Jendrike, N. R. M., Haug, C., & Freckmann, G. (2016) · Current Medical Research and Opinion · doi:10.1185/03007995.2016.1146666 · Cited by 6
Filali‐Ansary, A., Augé, C., Abgrall, A., Souchaud, M., Pellissier, F., Mordt, O. V., Blesson, S., & Sanderink, G. (2016) · Bioanalysis · doi:10.4155/bio-2016-0110 · Cited by 6
Baumdicker, F., & Hölker, U. (2020) · Statistics & Probability Letters · doi:10.1016/j.spl.2020.108801 · Cited by 6
Evaluation of five widely used serologic assays for antibodies to SARS-CoV-2
Stocking, C. J., de Miguel, L., Suteu, G., Dressel, A., Soricelli, A., Roskos, M., Valor, S., Mutschmann, C., & März, W. (2021) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2021.115587 · Cited by 6
Scherer‐Burić, R. A., Lesser‐Wetzold, K., Nagel, D., Weigand, M., Spannagl, M., Teupser, D., & Bruegel, M. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13814 · Cited by 7
Metadata
- Authors
- Passing, H., & Bablok, W.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 1983
- Volume
- 21
- Issue
- 11
- Pages
- 709-720
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2020210187
- Cited by
- 1,513
- References
- 7
- Citations by year
- 2026: 32 · 2025: 67 · 2024: 60 · 2023: 84 · 2022: 63 · 2021: 70 · 2020: 86 · 2019: 72 · 2018: 64 · 2017: 72 · 2016: 67 · 2015: 74 · 2014: 61 · 2013: 50 · 2012: 48
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- edoc Publication server (Humboldt University of Berlin) (submittedVersion)
- edoc Publication server (Humboldt University of Berlin)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- method comparison, linear regression, measurement error, distribution-free statistics, clinical chemistry instrumentation
- MeSH terms
- Biometry, Chemistry, Clinical, Humans, Quality Control, Regression Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review